Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,7 +14,10 @@ 14 14 15 15 [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 -A list of available discrete input assignments is available in 17 +(% class="box infomessage" %) 18 +((( 19 +A list of available **discrete input** assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 20 +))) 18 18 19 19 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 20 20 ... ... @@ -95,6 +95,10 @@ 95 95 96 96 In this section: 97 97 101 +* Type of cell temperature sensors – a type of temperature sensors connected to BMS Logic devices and used to measure cells temperature; 102 +* Unused cell temperature sensors – a bitfield to select unused temperature sensors on each BMS Logic;ры на каждом BMS Logic; 103 +* Type of temperature sensors 1 and 2 – тип температурных датчиков, подключенных к BMS Main 3. 104 +* 98 98 * Type – a type of temperature sensors. 99 99 100 100 === Output discrete signals === ... ... @@ -105,31 +105,11 @@ 105 105 106 106 [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 107 107 108 -The device supports the following assignments for discrete outputs: 115 +(% class="box infomessage" %) 116 +((( 117 +A list of available **discrete output** assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 118 +))) 109 109 110 -* No output – output is not used. 111 -* Low SOC – a signal corresponding the low SOC of the battery; 112 -* High charging current – charging current is high; 113 -* Main contactor – state of the main contactor; 114 -* Charging – state of the charging contactor; 115 -* Allow charging – a signal for a charger to start charging; 116 -* Charging current present – the presence of the charging current; 117 -* Precharging – state of the precharging contactor; 118 -* Discharging – state of the discharging contactor; 119 -* Discharging current present – the presence of the discharging current; 120 -* Discharging (AUX) – state of the auxiliary discharging contactor; 121 -* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 122 -* Charging/discharging - state of the charging/discharging contactor; 123 -* Heater – a command to turn on a heater; 124 -* Cooler – a command to turn on a cooler; 125 -* Balancing 1 – balancing the first series of cells; 126 -* Balancing 2 – balancing the second series of cells; 127 -* Ready to charge – the battery is ready to be charged; 128 -* Ready to discharge – the battery is ready to be discharged; 129 -* Power up – an indication of BMS power status; 130 -* General error – state of the configurable (general) error; 131 -* External 1 – a signal that activates by the remote request. 132 - 133 133 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 134 134 135 135 [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]] ... ... @@ -142,7 +142,10 @@ 142 142 143 143 [[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]] 144 144 145 -The device supports the same switch assignments as discrete outputs (see [[Output discrete signals>>doc:||anchor="HOutputdiscretesignals"]]). 132 +(% class="box infomessage" %) 133 +((( 134 +A list of available **switch **assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 135 +))) 146 146 147 147 Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section: 148 148
- 1750259757728-314.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.5 KB - Content