Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 12.2
edited by Admin
on 2025/02/11 13:02
Change comment: There is no comment for this version
To version 18.3
edited by Admin
on 2025/06/18 15:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,7 +14,10 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -A list of available discrete input assignments is available in
17 +(% class="box infomessage" %)
18 +(((
19 +A list of available **discrete input** assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
20 +)))
18 18  
19 19  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
20 20  
... ... @@ -95,6 +95,10 @@
95 95  
96 96  In this section:
97 97  
101 +* Type of cell temperature sensors – a type of temperature sensors connected to BMS Logic devices and used to measure cells temperature;
102 +* Unused cell temperature sensors – a bitfield to select unused temperature sensors on each BMS Logic;ры на каждом BMS Logic;
103 +* Type of temperature sensors 1 and 2 – тип температурных датчиков, подключенных к BMS Main 3.
104 +*
98 98  * Type – a type of temperature sensors.
99 99  
100 100  === Output discrete signals ===
... ... @@ -105,31 +105,11 @@
105 105  
106 106  [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
107 107  
108 -The device supports the following assignments for discrete outputs:
115 +(% class="box infomessage" %)
116 +(((
117 +A list of available **discrete output** assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
118 +)))
109 109  
110 -* No output – output is not used.
111 -* Low SOC – a signal corresponding the low SOC of the battery;
112 -* High charging current – charging current is high;
113 -* Main contactor – state of the main contactor;
114 -* Charging – state of the charging contactor;
115 -* Allow charging – a signal for a charger to start charging;
116 -* Charging current present – the presence of the charging current;
117 -* Precharging – state of the precharging contactor;
118 -* Discharging – state of the discharging contactor;
119 -* Discharging current present – the presence of the discharging current;
120 -* Discharging (AUX) – state of the auxiliary discharging contactor;
121 -* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;
122 -* Charging/discharging - state of the charging/discharging contactor;
123 -* Heater – a command to turn on a heater;
124 -* Cooler – a command to turn on a cooler;
125 -* Balancing 1 – balancing the first series of cells;
126 -* Balancing 2 – balancing the second series of cells;
127 -* Ready to charge – the battery is ready to be charged;
128 -* Ready to discharge – the battery is ready to be discharged;
129 -* Power up – an indication of BMS power status;
130 -* General error – state of the configurable (general) error;
131 -* External 1 – a signal that activates by the remote request.
132 -
133 133  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
134 134  
135 135  [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]
... ... @@ -142,7 +142,10 @@
142 142  
143 143  [[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]]
144 144  
145 -The device supports the same switch assignments as discrete outputs (see [[Output discrete signals>>doc:||anchor="HOutputdiscretesignals"]]).
132 +(% class="box infomessage" %)
133 +(((
134 +A list of available **switch **assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
135 +)))
146 146  
147 147  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
148 148  
1750259757728-314.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.5 KB
Content