Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,7 +14,7 @@ 14 14 15 15 [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 -A list of available discrete input assignments is available in 17 +A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 18 18 19 19 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 20 20 ... ... @@ -105,31 +105,8 @@ 105 105 106 106 [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 107 107 108 - The devicesupports thefollowing assignments fordiscreteutputs:108 +A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 109 109 110 -* No output – output is not used. 111 -* Low SOC – a signal corresponding the low SOC of the battery; 112 -* High charging current – charging current is high; 113 -* Main contactor – state of the main contactor; 114 -* Charging – state of the charging contactor; 115 -* Allow charging – a signal for a charger to start charging; 116 -* Charging current present – the presence of the charging current; 117 -* Precharging – state of the precharging contactor; 118 -* Discharging – state of the discharging contactor; 119 -* Discharging current present – the presence of the discharging current; 120 -* Discharging (AUX) – state of the auxiliary discharging contactor; 121 -* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 122 -* Charging/discharging - state of the charging/discharging contactor; 123 -* Heater – a command to turn on a heater; 124 -* Cooler – a command to turn on a cooler; 125 -* Balancing 1 – balancing the first series of cells; 126 -* Balancing 2 – balancing the second series of cells; 127 -* Ready to charge – the battery is ready to be charged; 128 -* Ready to discharge – the battery is ready to be discharged; 129 -* Power up – an indication of BMS power status; 130 -* General error – state of the configurable (general) error; 131 -* External 1 – a signal that activates by the remote request. 132 - 133 133 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 134 134 135 135 [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]