Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 12.2
edited by Admin
on 2025/02/11 13:02
Change comment: There is no comment for this version
To version 12.1
edited by Admin
on 2024/12/24 15:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,8 +14,30 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -A list of available discrete input assignments is available in
17 +The device supports the following assignments for discrete inputs:
18 18  
19 +* No input – input is not used;
20 +* Battery cover – a signal from the battery cover;
21 +* Charger connected – a signal indicating that charger is connected;
22 +* Power up/down request – a request to power down the device;
23 +* Inhibit charging – a command to open the charging contactor;
24 +* Inhibit discharging – a command to open the discharging contactor;
25 +* CH contactor feedback – a signal from charging contactor feedback loop;
26 +* DCH contactor feedback – a signal from discharging contactor feedback loop;
27 +* Insulation status – a signal from an insulation monitoring device;
28 +* Charge request – a request to close the charging contactor;
29 +* Precharge request – a request to close the precharging contactor;
30 +* Discharge request – a request to close the discharging contactor;
31 +* PCH contactor feedback – a signal from precharging contactor feedback loop;
32 +* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
33 +* Main contactor feedback – a signal from main contactor feedback loop;
34 +* Interlock – a signal from interlock loop;
35 +* Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
36 +* Circuit breaker status – status of protection disconnector;
37 +* Balancing request – a request to balance the cells;
38 +* Close Main contactor – a request to close the main contactor;
39 +* Close External 1 – a request to close the External 1 discrete output (if assigned).
40 +
19 19  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
20 20  
21 21  [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]]