Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,30 +14,8 @@ 14 14 15 15 [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 - The devicesupports thefollowing assignments fordiscreteinputs:17 +A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 18 18 19 -* No input – input is not used; 20 -* Battery cover – a signal from the battery cover; 21 -* Charger connected – a signal indicating that charger is connected; 22 -* Power up/down request – a request to power down the device; 23 -* Inhibit charging – a command to open the charging contactor; 24 -* Inhibit discharging – a command to open the discharging contactor; 25 -* CH contactor feedback – a signal from charging contactor feedback loop; 26 -* DCH contactor feedback – a signal from discharging contactor feedback loop; 27 -* Insulation status – a signal from an insulation monitoring device; 28 -* Charge request – a request to close the charging contactor; 29 -* Precharge request – a request to close the precharging contactor; 30 -* Discharge request – a request to close the discharging contactor; 31 -* PCH contactor feedback – a signal from precharging contactor feedback loop; 32 -* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 33 -* Main contactor feedback – a signal from main contactor feedback loop; 34 -* Interlock – a signal from interlock loop; 35 -* Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 36 -* Circuit breaker status – status of protection disconnector; 37 -* Balancing request – a request to balance the cells; 38 -* Close Main contactor – a request to close the main contactor; 39 -* Close External 1 – a request to close the External 1 discrete output (if assigned). 40 - 41 41 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 42 42 43 43 [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]] ... ... @@ -127,31 +127,8 @@ 127 127 128 128 [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 129 129 130 - The devicesupports thefollowing assignments fordiscreteutputs:108 +A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 131 131 132 -* No output – output is not used. 133 -* Low SOC – a signal corresponding the low SOC of the battery; 134 -* High charging current – charging current is high; 135 -* Main contactor – state of the main contactor; 136 -* Charging – state of the charging contactor; 137 -* Allow charging – a signal for a charger to start charging; 138 -* Charging current present – the presence of the charging current; 139 -* Precharging – state of the precharging contactor; 140 -* Discharging – state of the discharging contactor; 141 -* Discharging current present – the presence of the discharging current; 142 -* Discharging (AUX) – state of the auxiliary discharging contactor; 143 -* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 144 -* Charging/discharging - state of the charging/discharging contactor; 145 -* Heater – a command to turn on a heater; 146 -* Cooler – a command to turn on a cooler; 147 -* Balancing 1 – balancing the first series of cells; 148 -* Balancing 2 – balancing the second series of cells; 149 -* Ready to charge – the battery is ready to be charged; 150 -* Ready to discharge – the battery is ready to be discharged; 151 -* Power up – an indication of BMS power status; 152 -* General error – state of the configurable (general) error; 153 -* External 1 – a signal that activates by the remote request. 154 - 155 155 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 156 156 157 157 [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]