Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 11.2
edited by Admin
on 2024/12/24 15:39
Change comment: There is no comment for this version
To version 13.1
edited by Admin
on 2025/02/11 13:04
Change comment: Renamed back-links.

Summary

Details

Page properties
Content
... ... @@ -14,30 +14,8 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -The device supports the following assignments for discrete inputs:
17 +A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
18 18  
19 -* No input – input is not used;
20 -* Battery cover – a signal from the battery cover;
21 -* Charger connected – a signal indicating that charger is connected;
22 -* Power up/down request – a request to power down the device;
23 -* Inhibit charging – a command to open the charging contactor;
24 -* Inhibit discharging – a command to open the discharging contactor;
25 -* CH contactor feedback – a signal from charging contactor feedback loop;
26 -* DCH contactor feedback – a signal from discharging contactor feedback loop;
27 -* Insulation status – a signal from an insulation monitoring device;
28 -* Charge request – a request to close the charging contactor;
29 -* Precharge request – a request to close the precharging contactor;
30 -* Discharge request – a request to close the discharging contactor;
31 -* PCH contactor feedback – a signal from precharging contactor feedback loop;
32 -* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
33 -* Main contactor feedback – a signal from main contactor feedback loop;
34 -* Interlock – a signal from interlock loop;
35 -* Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
36 -* Circuit breaker status – status of protection disconnector;
37 -* Balancing request – a request to balance the cells;
38 -* Close Main contactor – a request to close the main contactor;
39 -* Close External 1 – a request to close the External 1 discrete output (if assigned).
40 -
41 41  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
42 42  
43 43  [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]]
... ... @@ -127,31 +127,8 @@
127 127  
128 128  [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
129 129  
130 -The device supports the following assignments for discrete outputs:
108 +A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
131 131  
132 -* No output – output is not used.
133 -* Low SOC – a signal corresponding the low SOC of the battery;
134 -* High charging current – charging current is high;
135 -* Main contactor – state of the main contactor;
136 -* Charging – state of the charging contactor;
137 -* Allow charging – a signal for a charger to start charging;
138 -* Charging current present – the presence of the charging current;
139 -* Precharging – state of the precharging contactor;
140 -* Discharging – state of the discharging contactor;
141 -* Discharging current present – the presence of the discharging current;
142 -* Discharging (AUX) – state of the auxiliary discharging contactor;
143 -* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;
144 -* Charging/discharging - state of the charging/discharging contactor;
145 -* Heater – a command to turn on a heater;
146 -* Cooler – a command to turn on a cooler;
147 -* Balancing 1 – balancing the first series of cells;
148 -* Balancing 2 – balancing the second series of cells;
149 -* Ready to charge – the battery is ready to be charged;
150 -* Ready to discharge – the battery is ready to be discharged;
151 -* Power up – an indication of BMS power status;
152 -* General error – state of the configurable (general) error;
153 -* External 1 – a signal that activates by the remote request.
154 -
155 155  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
156 156  
157 157  [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]
... ... @@ -168,5 +168,6 @@
168 168  
169 169  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
170 170  
126 +[[image:1735054793459-953.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]
171 171  
172 172