Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 10.2
edited by Admin
on 2024/12/24 15:38
Change comment: There is no comment for this version
To version 12.2
edited by Admin
on 2025/02/11 13:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,30 +14,8 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -The device supports the following assignments for discrete inputs:
17 +A list of available discrete input assignments is available in
18 18  
19 -* No input – input is not used;
20 -* Battery cover – a signal from the battery cover;
21 -* Charger connected – a signal indicating that charger is connected;
22 -* Power up/down request – a request to power down the device;
23 -* Inhibit charging – a command to open the charging contactor;
24 -* Inhibit discharging – a command to open the discharging contactor;
25 -* CH contactor feedback – a signal from charging contactor feedback loop;
26 -* DCH contactor feedback – a signal from discharging contactor feedback loop;
27 -* Insulation status – a signal from an insulation monitoring device;
28 -* Charge request – a request to close the charging contactor;
29 -* Precharge request – a request to close the precharging contactor;
30 -* Discharge request – a request to close the discharging contactor;
31 -* PCH contactor feedback – a signal from precharging contactor feedback loop;
32 -* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
33 -* Main contactor feedback – a signal from main contactor feedback loop;
34 -* Interlock – a signal from interlock loop;
35 -* Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
36 -* Circuit breaker status – status of protection disconnector;
37 -* Balancing request – a request to balance the cells;
38 -* Close Main contactor – a request to close the main contactor;
39 -* Close External 1 – a request to close the External 1 discrete output (if assigned).
40 -
41 41  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
42 42  
43 43  [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]]
... ... @@ -162,12 +162,12 @@
162 162  
163 163  Assignments of power switches are configured in the "Signals → Power switches → Assignments" section:
164 164  
165 -[[image:1735054694689-808.png]]
143 +[[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]]
166 166  
167 -The device supports the same switch assignments as discrete outputs.
145 +The device supports the same switch assignments as discrete outputs (see [[Output discrete signals>>doc:||anchor="HOutputdiscretesignals"]]).
168 168  
169 169  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
170 170  
171 -[[image:1733320685783-267.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="150" width="800"]]
149 +[[image:1735054793459-953.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]
172 172  
173 173  
1735054793459-953.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.3 KB
Content