Changes for page 3.1 General information
Last modified by Admin on 2026/03/30 10:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,39 +4,50 @@ 4 4 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == General information == 6 6 7 -This document describes how to configure the BMS Main 3 device.Configuringcan be done usingtheElectricDeviceMonitor above the 1.18.0 (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) via7 +This document describes how to configure the BMS Main 3 / BMS Main 2R device. 8 8 9 +Configuring can be done using the ElectricDeviceMonitor above the 1.18.0 (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) via 10 + 9 9 * USB; 10 10 * CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported); 11 -* TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3). 13 +* TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3 / BMS Main 2R). 12 12 15 +After connecting device to the PC, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window: 13 13 17 +(% aria-label="1735233230234-960.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]](% title="Click and drag to resize" %)(%%)Choose the connection type and set up connection settings: 14 14 15 - Toconnecttothedevice,launchElectricDeviceMonitor,select"Unifiedmonitor" in themain program window:19 +* **Serial port (USB)**: choose the corresponding COM port; 16 16 17 -[[image:173 5233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]21 +(% aria-label="1733320484262-545.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1733320484262-545.png||data-xwiki-image-style-alignment="center" height="311" width="450"]](% title="Click and drag to resize" %)(% aria-label="1733320484267-118.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1733320484267-118.png||data-xwiki-image-style-alignment="center" height="248" width="450"]] 18 18 19 -Cho ose the connectiontype andsetup connectionsettings:23 +* **Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN**: select the device in device list, specify the CAN speed and BMS device address: 20 20 21 - *Serialport(USB):choosethecorrespondingCOM port;25 +(% aria-label="1735233434987-983.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1735233434987-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]](% style="text-align:center" %) 22 22 23 -[[image:1733320484262-545.png||data-xwiki-image-style-alignment="center" height="311" width="450"]][[image:1733320484267-118.png||data-xwiki-image-style-alignment="center" height="248" width="450"]] 27 +(% class="box infomessage" %) 28 +((( 29 +Configuration may be done only via **CAN1 and CAN2** buses. 30 +))) 24 24 25 -* Systec USB-CAN,PEAKUSB-CAN, MarathonUSB-CAN, BMS USB-CAN: selectthe device indevice list,specifytheCAN speedand BMS device address:32 +* **TCP connection**: set up the device IP address. 26 26 27 - [[image:1735233434987-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]34 +(% aria-label="1743088757725-539.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1743088757725-539.png||data-xwiki-image-style-alignment="center" height="248" width="450"]](% style="text-align:center" %) 28 28 29 - *TCPconnection: setthe deviceIPaddress36 +When connected, the device asks for an access password. 30 30 38 +Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu. 31 31 40 +|=User|=Default Password|=Description 41 +|Guest|guest|Guest access to view battery state. No permissions to change and view any settings 42 +|User|user|A common user access with permissions to change almost all the settings 43 +|Service|- (by request)|A service account for battery manufacturers. Has access to some additional settings 44 +|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others 32 32 33 - When connected,thedeviceasksfor an accesspassword. Forthe"User"account, the defaultpasswordis"user"(withoutquotes).46 +(% aria-label="1735053821120-339.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1735053821120-339.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]](% title="Click and drag to resize" %)(% style="text-align:center" %) 34 34 35 -[[image:1735053821120-339.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]] 36 - 37 37 After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State": 38 38 39 -[[image:1735053858994-348.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]] 50 +(% aria-label="1735053858994-348.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1735053858994-348.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]](% title="Click and drag to resize" %)(% aria-label="1735053858994-348.png image widget" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" contenteditable="false" role="region" style="background-image:url(https://docs.movicomelectric.com/webjars/wiki%3Axwiki/xwiki-platform-ckeditor-webjar/16.10.10/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% aria-label="1735053858994-348.png image widget" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" contenteditable="false" role="region" tabindex="-1" title="Click and drag to resize" %) 40 40 41 41 The monitor window is divided into three areas. The upper area displays controls for starting and stopping communication with the device, information about the device (its name, hardware and firmware versions, time on the device clock), and controls for performing actions with the device (change password, restart, reset, etc.). 42 42
- 1735234302538-838.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.2 KB - Content
- 1743088757725-539.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.1 KB - Content