Changes for page 3.1 General information

Last modified by Admin on 2026/03/30 10:13

From version 20.1
edited by Admin
on 2026/03/30 10:13
Change comment: There is no comment for this version
To version 7.4
edited by Admin
on 2024/12/26 17:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,50 +4,37 @@
4 4  (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == General information ==
6 6  
7 -This document describes how to configure the BMS Main 3 / BMS Main 2R device.
7 +This document describes how to configure the BMS Main 3 device. Configuring can be done using the ElectricDeviceMonitor above the 1.18.0 (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) via
8 8  
9 -Configuring can be done using the ElectricDeviceMonitor above the 1.18.0 (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) via
10 -
11 11  * USB;
12 12  * CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported);
13 -* TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3 / BMS Main 2R).
11 +* TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3).
14 14  
15 15  After connecting device to the PC, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window:
16 16  
17 -(% aria-label="1735233230234-960.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]](% title="Click and drag to resize" %)​(%%)Choose the connection type and set up connection settings:
15 +[[image:1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
18 18  
19 -* **Serial port (USB)**: choose the corresponding COM port;
17 +Choose the connection type and set up connection settings:
20 20  
21 -(% aria-label="1733320484262-545.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1733320484262-545.png||data-xwiki-image-style-alignment="center" height="311" width="450"]](% title="Click and drag to resize" %)​(% aria-label="1733320484267-118.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1733320484267-118.png||data-xwiki-image-style-alignment="center" height="248" width="450"]]
19 +* Serial port (USB): select the COM port
22 22  
23 -* **Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN**: select the device in device list, specify the CAN speed and BMS device address:
21 +[[image:1733320484267-118.png||data-xwiki-image-style-alignment="center" height="248" width="450"]]
24 24  
25 -(% aria-label="1735233434987-983.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1735233434987-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]](% style="text-align:center" %)​
23 +* Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN: select the device in device list, specify the CAN speed and BMS device address:
26 26  
27 -(% class="box infomessage" %)
28 -(((
29 -Configuration may be done only via **CAN1 and CAN2** buses.
30 -)))
25 +[[image:1735233434987-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
31 31  
32 -* **TCP connection**: set up the device IP address.
27 +TCP connection: set the device IP address
33 33  
34 -(% aria-label="1743088757725-539.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1743088757725-539.png||data-xwiki-image-style-alignment="center" height="248" width="450"]](% style="text-align:center" %)​
35 35  
36 -When connected, the device asks for an access password.
37 37  
38 -Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu.
31 +When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).
39 39  
40 -|=User|=Default Password|=Description
41 -|Guest|guest|Guest access to view battery state. No permissions to change and view any settings
42 -|User|user|A common user access with permissions to change almost all the settings
43 -|Service|- (by request)|A service account for battery manufacturers. Has access to some additional settings
44 -|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others
33 +[[image:1735053821120-339.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]]
45 45  
46 -(% aria-label="1735053821120-339.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1735053821120-339.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]](% title="Click and drag to resize" %)​(% style="text-align:center" %)​
47 -
48 48  After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":
49 49  
50 -(% aria-label="1735053858994-348.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1735053858994-348.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]](% title="Click and drag to resize" %)​(% aria-label="1735053858994-348.png image widget" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" contenteditable="false" role="region" style="background-image:url(https://docs.movicomelectric.com/webjars/wiki%3Axwiki/xwiki-platform-ckeditor-webjar/16.10.10/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" tabindex="-1" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% aria-label="1735053858994-348.png image widget" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" contenteditable="false" role="region" tabindex="-1" title="Click and drag to resize" %)​
37 +[[image:1735053858994-348.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]]
51 51  
52 52  The monitor window is divided into three areas. The upper area displays controls for starting and stopping communication with the device, information about the device (its name, hardware and firmware versions, time on the device clock), and controls for performing actions with the device (change password, restart, reset, etc.).
53 53  
1735234302538-838.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -14.2 KB
Content
1743088757725-539.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -15.1 KB
Content