Wiki source code of 2. Installation and connection
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
31.1 | 1 | (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) |
2 | = Installation and connection = | ||
![]() |
30.1 | 3 | |
![]() |
28.1 | 4 | == Installation procedure == |
![]() |
27.1 | 5 | |
![]() |
40.1 | 6 | The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. |
![]() |
27.1 | 7 | |
8 | Overall and mounting dimensions are shown in figure below. | ||
9 | |||
10 | (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1733311711953-224.png||data-xwiki-image-style-alignment="center" height="566" width="775"]](% title="Click and drag to resize" %) | ||
11 | |||
12 | |**Parameter**|**Value** | ||
13 | |Overall dimensions (length × width × height), mm|200 × 123 × 12 | ||
14 | |Mounting dimensions (length × width), mm|194 × 114 | ||
15 | |Mounting holes|M3 | ||
![]() |
45.1 | 16 | |Headers type X1-X9|Hirose ZE05 |
17 | |Headers type X11-X14|Molex series Mocro-Fit | ||
![]() |
27.1 | 18 | |
![]() |
30.1 | 19 | == Headers == |
![]() |
27.1 | 20 | |
![]() |
40.1 | 21 | The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below. |
![]() |
27.1 | 22 | |
23 | (% contenteditable="false" tabindex="-1" %) | ||
24 | ((( | ||
25 | [[image:1732119505664-787.png||data-xwiki-image-style-alignment="center" height="417" width="684"]] | ||
26 | ))) | ||
27 | |||
28 | (% class="box warningmessage" %) | ||
29 | ((( | ||
30 | **Attention!** | ||
31 | All headers are shown from the device side! | ||
32 | ))) | ||
33 | |||
![]() |
30.1 | 34 | === X1 – header to power the device === |
![]() |
27.1 | 35 | |
36 | (% class="wikigeneratedid" id="H" %) | ||
37 | (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] | ||
38 | |||
39 | |**Pin**|**Name**|**Description** | ||
40 | |**1–2, 5–6**|**GND**|Ground | ||
41 | |**3**|**KEYRUN**|Power-on signal | ||
42 | |**4**|**CHARGE_ON**|Power-on signal (battery charge requirement) | ||
43 | |**7–8**|**VIN**|Power line (9-32V) | ||
44 | |||
45 | Power supply connection diagram: | ||
46 | |||
47 | (% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]] | ||
48 | |||
![]() |
30.1 | 49 | === X2 – header for contactors === |
![]() |
27.1 | 50 | |
51 | (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) | ||
52 | |||
53 | |**Pin**|**Name**|**Description** | ||
54 | |**1–4, 8–9**|**GND**|Ground | ||
55 | |**5**|**CONT1_OUT**|Contactor control 1 (plus) | ||
56 | |**6**|**CONT2_OUT**|Contactor control 2 (plus) | ||
57 | |**7**|**CONT3_OUT**|Contactor control 3 (plus) | ||
58 | |**10**|**CONT4_OUT**|Contactor control 4 (plus) | ||
59 | |**11**|**CONT5_OUT**|Contactor control 5 (plus) | ||
60 | |**12**|**CONT6_OUT**|Contactor control 6 (plus) | ||
61 | |||
62 | Contactor connection diagram: | ||
63 | |||
64 | (% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]] | ||
65 | |||
![]() |
30.1 | 66 | === (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === |
![]() |
27.1 | 67 | |
68 | (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] | ||
69 | |||
70 | |**Pin**|**Name**|**Description** | ||
71 | |**1–8, 12, 16–17, 21**|**DIO_GND**|Ground of input and output signals | ||
![]() |
36.1 | 72 | |**9**|**DIN1_SIGNAL**|Discrete input 1 “dry contact” |
73 | |**10**|**DIN2_SIGNAL**|Discrete input 2 “dry contact” | ||
74 | |**11**|**DIN3_SIGNAL**|Discrete input 3 “dry contact” | ||
75 | |**13**|**DIN4_SIGNAL**|Discrete input 4 “dry contact” | ||
76 | |**14**|**DIN5_SIGNAL**|Discrete input 5 “dry contact” | ||
77 | |**15**|**DIN6_SIGNAL**|Discrete input 6 “dry contact” | ||
![]() |
27.1 | 78 | |**18**|**DIN7_VIN**|Discrete input 7 (signal detection with voltage 9-32V) |
79 | |**19**|**DIN8_VIN**|Discrete input 8 (signal detection with voltage 9-32V) | ||
80 | |**20**|**DOUT1_OD**|Discrete output 1 “open drain” (60 V, 1A) | ||
81 | |**22**|**DOUT2_OD**|Discrete output 2 “open drain” (60 V, 1A) | ||
82 | |**23**|**DOUT3_OD**|Discrete output 3 “open drain” (60 V, 1A) | ||
83 | |**24**|**DOUT4_OD**|Discrete output 4 “open drain” (60 V, 1A) | ||
84 | |||
85 | Connection diagram of a discrete input to a dry contact output: | ||
86 | |||
87 | (% aria-label="1732121887401-555.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121887401-555.png||data-xwiki-image-style-alignment="center" height="63" width="196"]](% title="Click and drag to resize" %)(%%)Connection diagram of a discrete input to an open collector output: | ||
88 | |||
89 | (% aria-label="1732122137116-973.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122137116-973.png||data-xwiki-image-style-alignment="center" height="100" width="274"]](% title="Click and drag to resize" %)(%%)Connection diagram for a discrete input for detecting a 9-32V signal: | ||
90 | |||
91 | (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: | ||
92 | |||
![]() |
30.1 | 93 | === X4 – header for HVIL === |
![]() |
27.1 | 94 | |
![]() |
30.1 | 95 | [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] |
![]() |
27.1 | 96 | |
97 | |**Pin**|**Name**|**Description** | ||
98 | |**1**|**-**|Not used | ||
99 | |**2**|**HVIL_OUT**|Output of the current measurement circuit in the current loop (lower potential, measuring shunt output) | ||
100 | |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) | ||
101 | |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) | ||
102 | |||
![]() |
40.1 | 103 | If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. |
![]() |
27.1 | 104 | |
105 | Connection diagram to the current loop: | ||
106 | |||
![]() |
31.1 | 107 | === X5 – header for current and temperature sensors === |
![]() |
27.1 | 108 | |
![]() |
30.1 | 109 | [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] |
![]() |
27.1 | 110 | |
111 | (% style="width:539px" %) | ||
112 | |**Pin**|**Name**|(% style="width:402px" %)**Description** | ||
113 | |**1**|**CS1_5V**|(% style="width:402px" %)Current sensor 1 power line (5 V, max 50 mA) | ||
114 | |**2–6**|**GND**|(% style="width:402px" %)Ground | ||
115 | |**7**|**CS1_IN1**|(% style="width:402px" %)Current sensor 1 signal line (for a dual-range current sensor, High range output) | ||
116 | |**8**|**CS1_REF_IN2**|(% style="width:402px" %)Current sensor 1 reference voltage signal line (for a dual-range current sensor, Low range output) | ||
117 | |**9**|**CS2_5V**|(% style="width:402px" %)Current sensor 2 power line (5 V, max 50 mA) | ||
118 | |**10**|**CS2_IN1**|(% style="width:402px" %)Current sensor 2 signal line (for a dual-range current sensor, High range output) | ||
119 | |**11**|**CS2_REF_IN2**|(% style="width:402px" %)Current sensor 2 reference voltage signal line (for a dual-range current sensor, Low range output) | ||
120 | |**12**|**CS3_5V**|(% style="width:402px" %)Current sensor 3 power line (5 V, max 50 mA) | ||
121 | |**13**|**CS3_IN1**|(% style="width:402px" %)Current sensor 3 signal line (for a dual-range current sensor, High range output) | ||
122 | |**14**|**CS3_REF_IN2**|(% style="width:402px" %)Current sensor 3 reference voltage signal line (for a dual-range current sensor, Low range output) | ||
123 | |**15**|**TEMP1**|(% style="width:402px" %)Temperature sensor 1 signal line (NTC-thermistor 100 kOhm) | ||
124 | |**16**|**TEMP2**|(% style="width:402px" %)Temperature sensor 2 signal line (NTC-thermistor 100 kOhm) | ||
125 | |||
126 | Current sensor connection diagram (using the example of LEM HASS 100-S): | ||
127 | |||
128 | [[image:1733316158040-285.png||data-xwiki-image-style-alignment="center" height="170" width="412"]] | ||
129 | |||
130 | Current sensor connection diagram (using the example of LEM DHAB S/118): | ||
131 | |||
132 | [[image:1733316170709-142.png||data-xwiki-image-style-alignment="center" height="171" width="413"]] | ||
133 | |||
134 | NTC-thermistor connection diagram: | ||
135 | |||
136 | [[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]] | ||
137 | |||
![]() |
30.1 | 138 | === X6 – header for CAN1 and RS-485-1 (external buses) === |
![]() |
27.1 | 139 | |
140 | [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] | ||
141 | |||
142 | |**Pin**|**Name**|**Description** | ||
143 | |**1**|**CAN1_H**|CAN1 line H for communication with external equipment | ||
144 | |**2**|**CAN1_L**|CAN1 line L for communication with external equipment | ||
145 | |**3**|**CAN1_RS485_1_GND**|Ground of CAN1 and RS-485-1 | ||
146 | |**4**|**RS485_1_A**|RS-485-1 line A for communication with external equipment | ||
147 | |**5**|**RS485_1_B**|RS-485-1 line B for communication with external equipment | ||
148 | |||
149 | Connection diagram to the CAN1 bus: | ||
150 | |||
151 | [[image:1733316241362-843.png||data-xwiki-image-style-alignment="center" height="153" width="410"]] | ||
152 | |||
153 | Connection diagram to the RS-485-1 bus: | ||
154 | |||
155 | [[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]] | ||
156 | |||
![]() |
30.1 | 157 | === X7 – header for CAN2 (internal bus) === |
![]() |
27.1 | 158 | |
159 | [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] | ||
160 | |||
161 | |**Pin**|**Name**|**Description** | ||
![]() |
38.1 | 162 | |**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices |
163 | |**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices | ||
![]() |
27.1 | 164 | |**3**|**GND**|Ground |
165 | |**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA) | ||
166 | |||
167 | Connection diagram to the CAN2 bus (using the example of connecting BMS Display 1.2): | ||
168 | |||
169 | [[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]] | ||
170 | |||
![]() |
30.1 | 171 | === X8 – header for CAN3 === |
![]() |
27.1 | 172 | |
173 | [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] | ||
174 | |||
175 | |**Pin**|**Name**|**Description** | ||
![]() |
38.1 | 176 | |**1**|**CAN3_H**|CAN3 line H |
177 | |**2**|**CAN3_L**|CAN3 line L | ||
![]() |
27.1 | 178 | |**3**|**GND**|Ground |
179 | |**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA) | ||
180 | |||
181 | (% class="box infomessage" %) | ||
182 | ((( | ||
![]() |
38.1 | 183 | **Note:** |
184 | CAN3 operates differently depending on used firmware: | ||
![]() |
27.1 | 185 | |
![]() |
38.1 | 186 | * **BMS Main 3:** CAN3 bus is reserved; |
![]() |
39.1 | 187 | * **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus: |
![]() |
38.1 | 188 | |
189 | [[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] | ||
190 | ))) | ||
![]() |
27.1 | 191 | |
![]() |
30.1 | 192 | === X9 – header for BMS Logic (RS-485-2) === |
![]() |
27.1 | 193 | |
194 | [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] | ||
195 | |||
196 | |**Pin**|**Name**|**Description** | ||
197 | |**1**|**LOGIC_B**|RS-485 line B for communication with BMS Logic | ||
198 | |**2**|**LOGIC_A**|RS-485 line A for communication with BMS Logic | ||
199 | |**3**|**GND**|Ground | ||
200 | |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) | ||
201 | |||
![]() |
40.1 | 202 | (% class="box infomessage" %) |
203 | ((( | ||
204 | **Note:** | ||
205 | RS-485-2 operates differently depending on used firmware: | ||
![]() |
27.1 | 206 | |
![]() |
40.1 | 207 | * **BMS Main 3X:** RS-485-2 bus is reserved; |
208 | * **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: | ||
![]() |
27.1 | 209 | |
![]() |
40.1 | 210 | [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] |
211 | ))) | ||
212 | |||
![]() |
30.1 | 213 | === X10 – miniUSB connector === |
![]() |
27.1 | 214 | |
![]() |
41.1 | 215 | The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device. |
![]() |
27.1 | 216 | |
![]() |
30.1 | 217 | === X11 – header for high-voltage bus before contactors (plus) === |
![]() |
27.1 | 218 | |
219 | [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] | ||
220 | |||
221 | |**Pin**|**Name**|**Description** | ||
222 | |**1**|**IN1+**|Plus of the high-voltage bus (before contactors) | ||
223 | |**2**|**IN1+**|Plus of the high-voltage bus (before contactors) | ||
224 | |||
225 | (% class="box warningmessage" %) | ||
226 | ((( | ||
227 | The connected voltage must not exceed 1000V. | ||
228 | ))) | ||
229 | |||
![]() |
30.1 | 230 | === X12 – header for high-voltage bus before contactors (minus) === |
![]() |
27.1 | 231 | |
232 | [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] | ||
233 | |||
234 | |**Pin**|**Name**|**Description** | ||
235 | |**1**|**IN1-**|Minus of the high-voltage bus (before contactors) | ||
236 | |**2**|**IN1-**|Minus of the high-voltage bus (before contactors) | ||
237 | |||
238 | (% class="box warningmessage" %) | ||
239 | ((( | ||
240 | The connected voltage must not exceed 1000V. | ||
241 | ))) | ||
242 | |||
![]() |
30.1 | 243 | === X13 – header for high-voltage bus after contactors (plus) === |
![]() |
27.1 | 244 | |
245 | [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] | ||
246 | |||
247 | |**Pin**|**Name**|**Description** | ||
248 | |**1**|**IN2+**|Plus of the high-voltage bus (after contactors) | ||
249 | |**2**|**IN2+**|Plus of the high-voltage bus (after contactors) | ||
250 | |||
251 | (% class="box warningmessage" %) | ||
252 | ((( | ||
253 | The connected voltage must not exceed 1000V. | ||
254 | ))) | ||
255 | |||
![]() |
30.1 | 256 | === X14 – header for high-voltage bus after contactors (minus) === |
![]() |
27.1 | 257 | |
258 | [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] | ||
259 | |||
260 | |**Pin**|**Name**|**Description** | ||
261 | |**1**|**IN2-**|Minus of the high-voltage bus (after contactors) | ||
262 | |**2**|**IN2-**|Minus of the high-voltage bus (after contactors) | ||
263 | |||
264 | (% class="box warningmessage" %) | ||
265 | ((( | ||
266 | The connected voltage must not exceed 1000V. | ||
267 | ))) | ||
268 | |||
![]() |
30.1 | 269 | === J1 – jumper for switching RS-485-1 bus terminal resistor === |
![]() |
27.1 | 270 | |
271 | [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] | ||
272 | |||
273 | To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: | ||
274 | |||
275 | |**Pin**|**Name**|**Description** | ||
276 | |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected | ||
277 | |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected | ||
278 | |||
![]() |
30.1 | 279 | === J2 – jumper for switching CAN1 bus terminal resistor === |
![]() |
27.1 | 280 | |
281 | |||
282 | [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table: | ||
283 | |||
284 | |**Pin**|**Name**|**Description** | ||
285 | |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected | ||
286 | |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected | ||
287 | |||
![]() |
30.1 | 288 | === J3 – jumper for switching CAN2 bus terminal resistor === |
![]() |
27.1 | 289 | |
290 | |||
291 | [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H** and **CAN2_L** lines, install a jumper. The jumper is installed according to the table: | ||
292 | |||
293 | |**Pin**|**Name**|**Description** | ||
294 | |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN2 bus is connected | ||
295 | |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN2 bus is disconnected | ||
296 | |||
![]() |
30.1 | 297 | === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === |
![]() |
27.1 | 298 | |
![]() |
41.1 | 299 | The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. |
![]() |
27.1 | 300 | |
![]() |
30.1 | 301 | == Indicators == |
![]() |
27.1 | 302 | |
![]() |
30.1 | 303 | === DS1 – LED indicating device power === |
![]() |
27.1 | 304 | |
305 | |**State**|**Description** | ||
306 | |**Lights up green**|Device power (+5V) is present | ||
307 | |**Doesn’t light up**|No device power | ||
308 | |||
![]() |
30.1 | 309 | === DS2 – LED indicating device work === |
![]() |
27.1 | 310 | |
311 | |**State**|**Description** | ||
312 | |**Blinking green**|Executing the battery management program | ||
313 | |**No blinking**|Program execution error | ||
314 | |||
![]() |
30.1 | 315 | === DS3 – LED indicating interaction with BMS Logic === |
![]() |
27.1 | 316 | |
317 | |**State**|**Description** | ||
318 | |**Blinking yellow**|The device interacts with BMS Logic devices | ||
319 | |**No blinking**|- | ||
320 | |||
![]() |
30.1 | 321 | === DS4 – LED indicating loss of connection with BMS Logic === |
![]() |
27.1 | 322 | |
323 | |**State**|**Description** | ||
324 | |**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost | ||
325 | |**No blinking**|Communication with BMS Logic is stable | ||
326 | |||
![]() |
30.1 | 327 | === DS5-DS10 – LEDs indicating contactor switches 1-6 === |
![]() |
27.1 | 328 | |
329 | |**State**|**Description** | ||
330 | |**Lights up green**|The switch supplies voltage to the contactor winding | ||
331 | |**Doesn’t light up**|The switch doesn’t supply voltage to the contactor winding | ||
332 | |||
![]() |
30.1 | 333 | === DS11 – LED indicating the presence of power supply for contactors === |
![]() |
27.1 | 334 | |
335 | |**State**|**Description** | ||
336 | |**Lights up green**|Power supply for contactor switches (9-32V) is present | ||
337 | |**Doesn’t light up**|Power supply for contactor switches (9-32V) is not present | ||
338 | |||
![]() |
30.1 | 339 | == Connection procedure == |
![]() |
27.1 | 340 | |
341 | (% class="box warningmessage" %) | ||
342 | ((( | ||
![]() |
42.1 | 343 | Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. |
![]() |
27.1 | 344 | ))) |
345 | |||
346 | All operations to connect the device must be carried out with the supply voltage removed. | ||
347 | |||
348 | * Connect the power contactors to header X2. | ||
349 | * Connect one or more current sensors, as well as external temperature sensors (if necessary) to header X5. | ||
350 | * Connect BMS Logic devices to header X9. | ||
351 | * Connect digital inputs and outputs (if necessary) to header X3. | ||
352 | * Connect the high voltage bus (if necessary) to headers X11-X14. | ||
353 | * Connect the high-voltage network integrity circuit (if necessary) to header X4. | ||
354 | * Connect external devices (if necessary) to header X6. | ||
355 | * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. | ||
![]() |
40.1 | 356 | * If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. |
![]() |
27.1 | 357 | * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied. |