Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,7 +5,7 @@ 5 5 6 6 To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 7 8 -Before use, configure the system , see [[Configuration>>doc:Battery management systems.BMSMain 3.3\. Configuration.WebHome]].Proper operation of the BMS is possible only if it is correctly configured.8 +Before use, configure the system. Proper operation of the BMS is possible only if it is correctly configured. 9 9 10 10 It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 11 ... ... @@ -386,18 +386,6 @@ 386 386 387 387 == Connection procedure == 388 388 389 -The BMS can connect to batteries with voltage levels dangerous to life and health. When working with high voltage batteries, follow electrical safety rules, use safety glasses, protective clothing, insulated tools and devices. 390 - 391 -(% class="box errormessage" %) 392 -((( 393 -**The system is not designed to operate with batteries with total voltage more than 3000V.** 394 -))) 395 - 396 -(% class="box warningmessage" %) 397 -((( 398 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. 399 -))) 400 - 401 401 All operations to connect the device must be carried out with the supply voltage removed. 402 402 403 403 * Connect the power contactors to header X2.