Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,6 +13,8 @@ 13 13 |Overall dimensions (length × width × height), mm|200 × 123 × 12 14 14 |Mounting dimensions (length × width), mm|194 × 114 15 15 |Mounting holes|M3 16 +|Headers X1-X9 type|Hirose ZE05 17 +|Headers X11-X14 type|Molex series Micro-Fit 16 16 17 17 == Headers == 18 18 ... ... @@ -31,8 +31,6 @@ 31 31 32 32 === X1 – header to power the device === 33 33 34 -Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 35 - 36 36 (% class="wikigeneratedid" id="H" %) 37 37 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 38 38 ... ... @@ -48,8 +48,6 @@ 48 48 49 49 === X2 – header for contactors === 50 50 51 -Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 52 - 53 53 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 54 54 55 55 |**Pin**|**Name**|**Description** ... ... @@ -67,8 +67,6 @@ 67 67 68 68 === (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 69 69 70 -Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 71 - 72 72 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 73 73 74 74 |**Pin**|**Name**|**Description** ... ... @@ -98,8 +98,6 @@ 98 98 99 99 === X4 – header for HVIL === 100 100 101 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 102 - 103 103 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 104 104 105 105 |**Pin**|**Name**|**Description** ... ... @@ -116,8 +116,6 @@ 116 116 117 117 === X5 – header for current and temperature sensors === 118 118 119 -Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 120 - 121 121 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 122 122 123 123 (% style="width:539px" %) ... ... @@ -149,8 +149,6 @@ 149 149 150 150 === X6 – header for CAN1 and RS-485-1 (external buses) === 151 151 152 -Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 153 - 154 154 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 155 155 156 156 |**Pin**|**Name**|**Description** ... ... @@ -170,8 +170,6 @@ 170 170 171 171 === X7 – header for CAN2 (internal bus) === 172 172 173 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 174 - 175 175 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 176 176 177 177 |**Pin**|**Name**|**Description** ... ... @@ -186,8 +186,6 @@ 186 186 187 187 === X8 – header for CAN3 === 188 188 189 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 190 - 191 191 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 192 192 193 193 |**Pin**|**Name**|**Description** ... ... @@ -209,8 +209,6 @@ 209 209 210 210 === X9 – header for BMS Logic (RS-485-2) === 211 211 212 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 213 - 214 214 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 215 215 216 216 |**Pin**|**Name**|**Description** ... ... @@ -236,8 +236,6 @@ 236 236 237 237 === X11 – header for high-voltage bus before contactors (plus) === 238 238 239 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 240 - 241 241 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 242 242 243 243 |**Pin**|**Name**|**Description** ... ... @@ -251,8 +251,6 @@ 251 251 252 252 === X12 – header for high-voltage bus before contactors (minus) === 253 253 254 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 255 - 256 256 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 257 257 258 258 |**Pin**|**Name**|**Description** ... ... @@ -266,8 +266,6 @@ 266 266 267 267 === X13 – header for high-voltage bus after contactors (plus) === 268 268 269 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 270 - 271 271 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 272 272 273 273 |**Pin**|**Name**|**Description** ... ... @@ -281,8 +281,6 @@ 281 281 282 282 === X14 – header for high-voltage bus after contactors (minus) === 283 283 284 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 285 - 286 286 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 287 287 288 288 |**Pin**|**Name**|**Description**