... ... @@ -1,6 +1,22 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 +== Safety rules ==
5 +
6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS.
7 +
8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 +
10 +(% class="box warningmessage" %)
11 +(((
12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 +)))
14 +
15 +(% class="box errormessage" %)
16 +(((
17 +**The system is not designed to operate with batteries whose total voltage exceeds 3000 V.**
18 +)))
19 +
4 4  == Installation procedure ==
5 5  
6 6  The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
... ... @@ -31,6 +31,8 @@
31 31  
32 32  === X1 – header to power the device ===
33 33  
50 +Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF
51 +
34 34  (% class="wikigeneratedid" id="H" %)
35 35  (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]]
36 36  
... ... @@ -46,6 +46,8 @@
46 46  
47 47  === X2 – header for contactors ===
48 48  
67 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF
68 +
49 49  (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %)​
50 50  
51 51  |**Pin**|**Name**|**Description**
... ... @@ -63,6 +63,8 @@
63 63  
64 64  === (% title="Click and drag to resize" %)​(%%)X3 – header for discrete inputs and outputs ===
65 65  
86 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF
87 +
66 66  (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]]
67 67  
68 68  |**Pin**|**Name**|**Description**
... ... @@ -92,6 +92,8 @@
92 92  
93 93  === X4 – header for HVIL ===
94 94  
117 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
118 +
95 95  [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]]
96 96  
97 97  |**Pin**|**Name**|**Description**
... ... @@ -108,6 +108,8 @@
108 108  
109 109  === X5 – header for current and temperature sensors ===
110 110  
135 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF
136 +
111 111  [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]]
112 112  
113 113  (% style="width:539px" %)
... ... @@ -139,6 +139,8 @@
139 139  
140 140  === X6 – header for CAN1 and RS-485-1 (external buses) ===
141 141  
168 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF
169 +
142 142  [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]]
143 143  
144 144  |**Pin**|**Name**|**Description**
... ... @@ -158,6 +158,8 @@
158 158  
159 159  === X7 – header for CAN2 (internal bus) ===
160 160  
189 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
190 +
161 161  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
162 162  
163 163  |**Pin**|**Name**|**Description**
... ... @@ -172,6 +172,8 @@
172 172  
173 173  === X8 – header for CAN3 ===
174 174  
205 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
206 +
175 175  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
176 176  
177 177  |**Pin**|**Name**|**Description**
... ... @@ -193,6 +193,8 @@
193 193  
194 194  === X9 – header for BMS Logic (RS-485-2) ===
195 195  
228 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
229 +
196 196  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
197 197  
198 198  |**Pin**|**Name**|**Description**
... ... @@ -218,6 +218,8 @@
218 218  
219 219  === X11 – header for high-voltage bus before contactors (plus) ===
220 220  
255 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
256 +
221 221  [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
222 222  
223 223  |**Pin**|**Name**|**Description**
... ... @@ -231,6 +231,8 @@
231 231  
232 232  === X12 – header for high-voltage bus before contactors (minus) ===
233 233  
270 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
271 +
234 234  [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
235 235  
236 236  |**Pin**|**Name**|**Description**
... ... @@ -244,6 +244,8 @@
244 244  
245 245  === X13 – header for high-voltage bus after contactors (plus) ===
246 246  
285 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
286 +
247 247  [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
248 248  
249 249  |**Pin**|**Name**|**Description**
... ... @@ -257,6 +257,8 @@
257 257  
258 258  === X14 – header for high-voltage bus after contactors (minus) ===
259 259  
300 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
301 +
260 260  [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
261 261  
262 262  |**Pin**|**Name**|**Description**
... ... @@ -342,18 +342,6 @@
342 342  
343 343  == Connection procedure ==
344 344  
345 -The BMS can connect to batteries with voltage levels dangerous to life and health. When working with high voltage batteries, follow electrical safety rules, use safety glasses, protective clothing, insulated tools and devices.
346 -
347 -(% class="box errormessage" %)
348 -(((
349 -**The system is not designed to operate with batteries with total voltage more than 3000V.**
350 -)))
351 -
352 -(% class="box warningmessage" %)
353 -(((
354 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.
355 -)))
356 -
357 357  All operations to connect the device must be carried out with the supply voltage removed.
358 358  