Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,24 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, configure the system, see [[Configuration>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 + 12 +(% class="box warningmessage" %) 13 +((( 14 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 15 +))) 16 + 17 +(% class="box errormessage" %) 18 +((( 19 +**The system is not designed to operate with batteries whose total voltage exceeds 3000 V.** 20 +))) 21 + 4 4 == Installation procedure == 5 5 6 6 The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. ... ... @@ -31,6 +31,8 @@ 31 31 32 32 === X1 – header to power the device === 33 33 52 +Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 53 + 34 34 (% class="wikigeneratedid" id="H" %) 35 35 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 36 36 ... ... @@ -46,6 +46,8 @@ 46 46 47 47 === X2 – header for contactors === 48 48 69 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 70 + 49 49 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 50 50 51 51 |**Pin**|**Name**|**Description** ... ... @@ -63,6 +63,8 @@ 63 63 64 64 === (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 65 65 88 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 89 + 66 66 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 67 67 68 68 |**Pin**|**Name**|**Description** ... ... @@ -92,6 +92,8 @@ 92 92 93 93 === X4 – header for HVIL === 94 94 119 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 120 + 95 95 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 96 96 97 97 |**Pin**|**Name**|**Description** ... ... @@ -108,6 +108,8 @@ 108 108 109 109 === X5 – header for current and temperature sensors === 110 110 137 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 138 + 111 111 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 112 112 113 113 (% style="width:539px" %) ... ... @@ -139,6 +139,8 @@ 139 139 140 140 === X6 – header for CAN1 and RS-485-1 (external buses) === 141 141 170 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 171 + 142 142 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 143 143 144 144 |**Pin**|**Name**|**Description** ... ... @@ -158,6 +158,8 @@ 158 158 159 159 === X7 – header for CAN2 (internal bus) === 160 160 191 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 192 + 161 161 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 162 162 163 163 |**Pin**|**Name**|**Description** ... ... @@ -172,6 +172,8 @@ 172 172 173 173 === X8 – header for CAN3 === 174 174 207 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 208 + 175 175 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 176 176 177 177 |**Pin**|**Name**|**Description** ... ... @@ -193,6 +193,8 @@ 193 193 194 194 === X9 – header for BMS Logic (RS-485-2) === 195 195 230 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 231 + 196 196 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 197 197 198 198 |**Pin**|**Name**|**Description** ... ... @@ -218,6 +218,8 @@ 218 218 219 219 === X11 – header for high-voltage bus before contactors (plus) === 220 220 257 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 258 + 221 221 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 222 222 223 223 |**Pin**|**Name**|**Description** ... ... @@ -231,6 +231,8 @@ 231 231 232 232 === X12 – header for high-voltage bus before contactors (minus) === 233 233 272 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 273 + 234 234 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 235 235 236 236 |**Pin**|**Name**|**Description** ... ... @@ -244,6 +244,8 @@ 244 244 245 245 === X13 – header for high-voltage bus after contactors (plus) === 246 246 287 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 288 + 247 247 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 248 248 249 249 |**Pin**|**Name**|**Description** ... ... @@ -257,6 +257,8 @@ 257 257 258 258 === X14 – header for high-voltage bus after contactors (minus) === 259 259 302 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 303 + 260 260 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 261 261 262 262 |**Pin**|**Name**|**Description**