Last modified by Admin on 2025/03/18 12:51

From version 55.1
edited by Admin
on 2025/02/12 12:15
Change comment: There is no comment for this version
To version 55.3
edited by Admin
on 2025/02/20 13:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -13,8 +13,6 @@
13 13  |Overall dimensions (length × width × height), mm|200 × 123 × 12
14 14  |Mounting dimensions (length × width), mm|194 × 114
15 15  |Mounting holes|M3
16 -|Headers X1-X9 type|Hirose ZE05
17 -|Headers X11-X14 type|Molex series Micro-Fit
18 18  
19 19  == Headers ==
20 20  
... ... @@ -33,6 +33,8 @@
33 33  
34 34  === X1 – header to power the device ===
35 35  
34 +Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF
35 +
36 36  (% class="wikigeneratedid" id="H" %)
37 37  (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]]
38 38  
... ... @@ -48,6 +48,8 @@
48 48  
49 49  === X2 – header for contactors ===
50 50  
51 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF
52 +
51 51  (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %)​
52 52  
53 53  |**Pin**|**Name**|**Description**
... ... @@ -65,6 +65,8 @@
65 65  
66 66  === (% title="Click and drag to resize" %)​(%%)X3 – header for discrete inputs and outputs ===
67 67  
70 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF
71 +
68 68  (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]]
69 69  
70 70  |**Pin**|**Name**|**Description**
... ... @@ -94,6 +94,8 @@
94 94  
95 95  === X4 – header for HVIL ===
96 96  
101 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
102 +
97 97  [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]]
98 98  
99 99  |**Pin**|**Name**|**Description**
... ... @@ -110,6 +110,8 @@
110 110  
111 111  === X5 – header for current and temperature sensors ===
112 112  
119 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF
120 +
113 113  [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]]
114 114  
115 115  (% style="width:539px" %)
... ... @@ -141,6 +141,8 @@
141 141  
142 142  === X6 – header for CAN1 and RS-485-1 (external buses) ===
143 143  
152 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF
153 +
144 144  [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]]
145 145  
146 146  |**Pin**|**Name**|**Description**
... ... @@ -160,6 +160,8 @@
160 160  
161 161  === X7 – header for CAN2 (internal bus) ===
162 162  
173 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
174 +
163 163  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
164 164  
165 165  |**Pin**|**Name**|**Description**
... ... @@ -174,6 +174,8 @@
174 174  
175 175  === X8 – header for CAN3 ===
176 176  
189 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
190 +
177 177  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
178 178  
179 179  |**Pin**|**Name**|**Description**
... ... @@ -195,6 +195,8 @@
195 195  
196 196  === X9 – header for BMS Logic (RS-485-2) ===
197 197  
212 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
213 +
198 198  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
199 199  
200 200  |**Pin**|**Name**|**Description**
... ... @@ -220,6 +220,8 @@
220 220  
221 221  === X11 – header for high-voltage bus before contactors (plus) ===
222 222  
239 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
240 +
223 223  [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
224 224  
225 225  |**Pin**|**Name**|**Description**
... ... @@ -233,6 +233,8 @@
233 233  
234 234  === X12 – header for high-voltage bus before contactors (minus) ===
235 235  
254 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
255 +
236 236  [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
237 237  
238 238  |**Pin**|**Name**|**Description**
... ... @@ -246,6 +246,8 @@
246 246  
247 247  === X13 – header for high-voltage bus after contactors (plus) ===
248 248  
269 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
270 +
249 249  [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
250 250  
251 251  |**Pin**|**Name**|**Description**
... ... @@ -259,6 +259,8 @@
259 259  
260 260  === X14 – header for high-voltage bus after contactors (minus) ===
261 261  
284 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
285 +
262 262  [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]