Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,22 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +(% class="box warningmessage" %) 11 +((( 12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 +))) 14 + 15 +(% class="box errormessage" %) 16 +((( 17 +**The system is not designed to operate with batteries whose total voltage exceeds 3000 V.** 18 +))) 19 + 4 4 == Installation procedure == 5 5 6 6 The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. ... ... @@ -13,8 +13,6 @@ 13 13 |Overall dimensions (length × width × height), mm|200 × 123 × 12 14 14 |Mounting dimensions (length × width), mm|194 × 114 15 15 |Mounting holes|M3 16 -|Headers X1-X9 type|Hirose ZE05 17 -|Headers X11-X14 type|Molex series Micro-Fit 18 18 19 19 == Headers == 20 20 ... ... @@ -33,6 +33,8 @@ 33 33 34 34 === X1 – header to power the device === 35 35 50 +Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 51 + 36 36 (% class="wikigeneratedid" id="H" %) 37 37 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 38 38 ... ... @@ -48,6 +48,8 @@ 48 48 49 49 === X2 – header for contactors === 50 50 67 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 68 + 51 51 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 52 52 53 53 |**Pin**|**Name**|**Description** ... ... @@ -65,6 +65,8 @@ 65 65 66 66 === (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 67 67 86 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 87 + 68 68 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 69 69 70 70 |**Pin**|**Name**|**Description** ... ... @@ -94,6 +94,8 @@ 94 94 95 95 === X4 – header for HVIL === 96 96 117 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 118 + 97 97 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 98 98 99 99 |**Pin**|**Name**|**Description** ... ... @@ -110,6 +110,8 @@ 110 110 111 111 === X5 – header for current and temperature sensors === 112 112 135 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 136 + 113 113 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 114 114 115 115 (% style="width:539px" %) ... ... @@ -141,6 +141,8 @@ 141 141 142 142 === X6 – header for CAN1 and RS-485-1 (external buses) === 143 143 168 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 169 + 144 144 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 145 145 146 146 |**Pin**|**Name**|**Description** ... ... @@ -160,6 +160,8 @@ 160 160 161 161 === X7 – header for CAN2 (internal bus) === 162 162 189 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 190 + 163 163 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 164 164 165 165 |**Pin**|**Name**|**Description** ... ... @@ -174,6 +174,8 @@ 174 174 175 175 === X8 – header for CAN3 === 176 176 205 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 206 + 177 177 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 178 178 179 179 |**Pin**|**Name**|**Description** ... ... @@ -195,6 +195,8 @@ 195 195 196 196 === X9 – header for BMS Logic (RS-485-2) === 197 197 228 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 229 + 198 198 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 199 199 200 200 |**Pin**|**Name**|**Description** ... ... @@ -220,6 +220,8 @@ 220 220 221 221 === X11 – header for high-voltage bus before contactors (plus) === 222 222 255 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 256 + 223 223 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 224 224 225 225 |**Pin**|**Name**|**Description** ... ... @@ -233,6 +233,8 @@ 233 233 234 234 === X12 – header for high-voltage bus before contactors (minus) === 235 235 270 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 271 + 236 236 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 237 237 238 238 |**Pin**|**Name**|**Description** ... ... @@ -246,6 +246,8 @@ 246 246 247 247 === X13 – header for high-voltage bus after contactors (plus) === 248 248 285 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 286 + 249 249 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 250 250 251 251 |**Pin**|**Name**|**Description** ... ... @@ -259,6 +259,8 @@ 259 259 260 260 === X14 – header for high-voltage bus after contactors (minus) === 261 261 300 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 301 + 262 262 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 263 263 264 264 |**Pin**|**Name**|**Description** ... ... @@ -325,9 +325,10 @@ 325 325 326 326 === DS4 – LED indicating loss of connection with child devices === 327 327 328 -|**State**|**Description (Main 3)**| 329 -|**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost| 330 -|**No blinking**|Communication with BMS Logic is stable| 368 +(% style="width:601px" %) 369 +|**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)** 370 +|**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost 371 +|**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable 331 331 332 332 === DS5-DS10 – LEDs indicating contactor switches 1-6 === 333 333 ... ... @@ -343,18 +343,6 @@ 343 343 344 344 == Connection procedure == 345 345 346 -The BMS can connect to batteries with voltage levels dangerous to life and health. When working with high voltage batteries, follow electrical safety rules, use safety glasses, protective clothing, insulated tools and devices. 347 - 348 -(% class="box errormessage" %) 349 -((( 350 -**The system is not designed to operate with batteries with total voltage more than 3000V.** 351 -))) 352 - 353 -(% class="box warningmessage" %) 354 -((( 355 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. 356 -))) 357 - 358 358 All operations to connect the device must be carried out with the supply voltage removed. 359 359 360 360 * Connect the power contactors to header X2.