Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 / BMS Main 3Xdevice must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.6 +The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -13,12 +13,10 @@ 13 13 |Overall dimensions (length × width × height), mm|200 × 123 × 12 14 14 |Mounting dimensions (length × width), mm|194 × 114 15 15 |Mounting holes|M3 16 -|Headers X1-X9 type|Hirose ZE05 17 -|Headers X11-X14 type|Molex series Micro-Fit 18 18 19 19 == Headers == 20 20 21 -The location and designation of connectors on the BMS Main 3 / BMS Main 3Xdevice are shown below.19 +The location and designation of connectors on the BMS Main 3 device are shown below. 22 22 23 23 (% contenteditable="false" tabindex="-1" %) 24 24 ((( ... ... @@ -90,8 +90,6 @@ 90 90 91 91 (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 92 92 93 -[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]] 94 - 95 95 === X4 – header for HVIL === 96 96 97 97 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] ... ... @@ -102,12 +102,10 @@ 102 102 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 103 103 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 104 104 105 - If the BMS Main 3 / BMS Main 3Xdevice generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3/ BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.101 + If the BMS Main 3 device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 106 106 107 107 Connection diagram to the current loop: 108 108 109 -[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 110 - 111 111 === X5 – header for current and temperature sensors === 112 112 113 113 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] ... ... @@ -203,20 +203,13 @@ 203 203 |**3**|**GND**|Ground 204 204 |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 205 205 206 -(% class="box infomessage" %) 207 -((( 208 -**Note:** 209 -RS-485-2 operates differently depending on used firmware: 200 +Connection diagram for BMS Logic devices: 210 210 211 -* **BMS Main 3X:** RS-485-2 bus is reserved; 212 -* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 202 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]] 213 213 214 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 215 -))) 216 - 217 217 === X10 – miniUSB connector === 218 218 219 -The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3Xdevice.206 +The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 220 220 221 221 === X11 – header for high-voltage bus before contactors (plus) === 222 222 ... ... @@ -300,7 +300,7 @@ 300 300 301 301 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 302 302 303 -The BMS Main 3 / BMS Main 3Xdevice implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.290 +The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 304 304 305 305 == Indicators == 306 306 ... ... @@ -342,16 +342,9 @@ 342 342 343 343 == Connection procedure == 344 344 345 -The BMS can connect to batteries with voltage levels dangerous to life and health. When working with high voltage batteries, follow electrical safety rules, use safety glasses, protective clothing, insulated tools and devices. 346 - 347 -(% class="box errormessage" %) 348 -((( 349 -**The system is not designed to operate with batteries with total voltage more than 3000V.** 350 -))) 351 - 352 352 (% class="box warningmessage" %) 353 353 ((( 354 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.334 +Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Settings.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. 355 355 ))) 356 356 357 357 All operations to connect the device must be carried out with the supply voltage removed. ... ... @@ -364,5 +364,5 @@ 364 364 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 365 365 * Connect external devices (if necessary) to header X6. 366 366 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 367 -* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.347 +* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 368 368 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.
- 1739361236606-576.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.8 KB - Content
- 1739361269041-663.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -9.0 KB - Content
- 1739361333964-462.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.2 KB - Content
- 1739361367866-742.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.1 KB - Content