Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,16 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +(% class="box warningmessage" %) 5 +((( 6 +The BMS can connect to batteries with voltage levels dangerous to life and health. When working with high voltage batteries, follow electrical safety rules, use safety glasses, protective clothing, insulated tools and devices. 7 +))) 8 + 9 +(% class="box errormessage" %) 10 +((( 11 +**The system is not designed to operate with batteries whose total voltage exceeds 3000 V.** 12 +))) 13 + 4 4 == Installation procedure == 5 5 6 6 The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. ... ... @@ -13,8 +13,6 @@ 13 13 |Overall dimensions (length × width × height), mm|200 × 123 × 12 14 14 |Mounting dimensions (length × width), mm|194 × 114 15 15 |Mounting holes|M3 16 -|Headers X1-X9 type|Hirose ZE05 17 -|Headers X11-X14 type|Molex series Micro-Fit 18 18 19 19 == Headers == 20 20 ... ... @@ -33,6 +33,8 @@ 33 33 34 34 === X1 – header to power the device === 35 35 44 +Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 45 + 36 36 (% class="wikigeneratedid" id="H" %) 37 37 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 38 38 ... ... @@ -48,6 +48,8 @@ 48 48 49 49 === X2 – header for contactors === 50 50 61 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 62 + 51 51 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 52 52 53 53 |**Pin**|**Name**|**Description** ... ... @@ -65,6 +65,8 @@ 65 65 66 66 === (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 67 67 80 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 81 + 68 68 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 69 69 70 70 |**Pin**|**Name**|**Description** ... ... @@ -94,6 +94,8 @@ 94 94 95 95 === X4 – header for HVIL === 96 96 111 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 112 + 97 97 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 98 98 99 99 |**Pin**|**Name**|**Description** ... ... @@ -106,8 +106,12 @@ 106 106 107 107 Connection diagram to the current loop: 108 108 125 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 126 + 109 109 === X5 – header for current and temperature sensors === 110 110 129 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 130 + 111 111 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 112 112 113 113 (% style="width:539px" %) ... ... @@ -139,6 +139,8 @@ 139 139 140 140 === X6 – header for CAN1 and RS-485-1 (external buses) === 141 141 162 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 163 + 142 142 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 143 143 144 144 |**Pin**|**Name**|**Description** ... ... @@ -158,6 +158,8 @@ 158 158 159 159 === X7 – header for CAN2 (internal bus) === 160 160 183 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 184 + 161 161 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 162 162 163 163 |**Pin**|**Name**|**Description** ... ... @@ -172,6 +172,8 @@ 172 172 173 173 === X8 – header for CAN3 === 174 174 199 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 200 + 175 175 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 176 176 177 177 |**Pin**|**Name**|**Description** ... ... @@ -193,6 +193,8 @@ 193 193 194 194 === X9 – header for BMS Logic (RS-485-2) === 195 195 222 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 223 + 196 196 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 197 197 198 198 |**Pin**|**Name**|**Description** ... ... @@ -218,6 +218,8 @@ 218 218 219 219 === X11 – header for high-voltage bus before contactors (plus) === 220 220 249 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 250 + 221 221 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 222 222 223 223 |**Pin**|**Name**|**Description** ... ... @@ -231,6 +231,8 @@ 231 231 232 232 === X12 – header for high-voltage bus before contactors (minus) === 233 233 264 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 265 + 234 234 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 235 235 236 236 |**Pin**|**Name**|**Description** ... ... @@ -244,6 +244,8 @@ 244 244 245 245 === X13 – header for high-voltage bus after contactors (plus) === 246 246 279 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 280 + 247 247 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 248 248 249 249 |**Pin**|**Name**|**Description** ... ... @@ -257,6 +257,8 @@ 257 257 258 258 === X14 – header for high-voltage bus after contactors (minus) === 259 259 294 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 295 + 260 260 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 261 261 262 262 |**Pin**|**Name**|**Description** ... ... @@ -314,17 +314,19 @@ 314 314 |**Blinking green**|Executing the battery management program 315 315 |**No blinking**|Program execution error 316 316 317 -=== DS3 – LED indicating interaction with BMSLogic ===353 +=== DS3 – LED indicating interaction with child devices === 318 318 319 -|**State**|**Description** 320 -|**Blinking yellow**|The device interacts with BMS Logic devices 321 -|**No blinking**|- 355 +(% style="width:447px" %) 356 +|**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)** 357 +|**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices 358 +|**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)- 322 322 323 -=== DS4 – LED indicating loss of connection with BMS Logic ===360 +=== DS4 – LED indicating loss of connection with child devices === 324 324 325 -|**State**|**Description** 326 -|**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost 327 -|**No blinking**|Communication with BMS Logic is stable 362 +(% style="width:601px" %) 363 +|**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)** 364 +|**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost 365 +|**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable 328 328 329 329 === DS5-DS10 – LEDs indicating contactor switches 1-6 === 330 330