Last modified by Admin on 2025/03/18 12:51

From version 53.1
edited by Admin
on 2025/02/12 11:56
Change comment: Uploaded new attachment "1739361367866-742.png", version {1}
To version 40.1
edited by Admin
on 2024/12/12 16:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -13,8 +13,6 @@
13 13  |Overall dimensions (length × width × height), mm|200 × 123 × 12
14 14  |Mounting dimensions (length × width), mm|194 × 114
15 15  |Mounting holes|M3
16 -|Headers X1-X9 type|Hirose ZE05
17 -|Headers X11-X14 type|Molex series Micro-Fit
18 18  
19 19  == Headers ==
20 20  
... ... @@ -90,8 +90,6 @@
90 90  
91 91  (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)​(%%)Connection diagram for discrete output:
92 92  
93 -[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]]
94 -
95 95  === X4 – header for HVIL ===
96 96  
97 97  [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]]
... ... @@ -214,7 +214,7 @@
214 214  
215 215  === X10 – miniUSB connector ===
216 216  
217 -The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device.
213 +The miniUSB connector is used to configure the parameters of the BMS Main 3  device.
218 218  
219 219  === X11 – header for high-voltage bus before contactors (plus) ===
220 220  
... ... @@ -298,7 +298,7 @@
298 298  
299 299  === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
300 300  
301 -The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
297 +The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
302 302  
303 303  == Indicators ==
304 304  
... ... @@ -340,16 +340,9 @@
340 340  
341 341  == Connection procedure ==
342 342  
343 -The BMS can connect to batteries with voltage levels dangerous to life and health. When working with high voltage batteries, follow electrical safety rules, use safety glasses, protective clothing, insulated tools and devices.
344 -
345 -(% class="box errormessage" %)
346 -(((
347 -**The system is not designed to operate with batteries with total voltage more than 3000V.**
348 -)))
349 -
350 350  (% class="box warningmessage" %)
351 351  (((
352 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.
341 +Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Settings.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.
353 353  )))
354 354  
355 355  All operations to connect the device must be carried out with the supply voltage removed.
1739361236606-576.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -7.8 KB
Content
1739361269041-663.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -9.0 KB
Content
1739361333964-462.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -15.2 KB
Content
1739361367866-742.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -21.1 KB
Content