Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -90,6 +90,8 @@ 90 90 91 91 (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 92 92 93 +[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]] 94 + 93 93 === X4 – header for HVIL === 94 94 95 95 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] ... ... @@ -104,6 +104,8 @@ 104 104 105 105 Connection diagram to the current loop: 106 106 109 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 110 + 107 107 === X5 – header for current and temperature sensors === 108 108 109 109 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] ... ... @@ -312,17 +312,18 @@ 312 312 |**Blinking green**|Executing the battery management program 313 313 |**No blinking**|Program execution error 314 314 315 -=== DS3 – LED indicating interaction with BMSLogic ===319 +=== DS3 – LED indicating interaction with child devices === 316 316 317 -|**State**|**Description** 318 -|**Blinking yellow**|The device interacts with BMS Logic devices 319 -|**No blinking**|- 321 +(% style="width:447px" %) 322 +|**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)** 323 +|**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices 324 +|**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)- 320 320 321 -=== DS4 – LED indicating loss of connection with BMS Logic ===326 +=== DS4 – LED indicating loss of connection with child devices === 322 322 323 -|**State**|**Description** 324 -|**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost 325 -|**No blinking**|Communication with BMS Logic is stable 328 +|**State**|**Description**| 329 +|**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost| 330 +|**No blinking**|Communication with BMS Logic is stable| 326 326 327 327 === DS5-DS10 – LEDs indicating contactor switches 1-6 === 328 328 ... ... @@ -342,7 +342,7 @@ 342 342 343 343 (% class="box errormessage" %) 344 344 ((( 345 -**The system is not designed to operate with batteries with total voltage e xceeds3000V.**350 +**The system is not designed to operate with batteries with total voltage more than 3000V.** 346 346 ))) 347 347 348 348 (% class="box warningmessage" %)
- 1739361236606-576.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.8 KB - Content
- 1739361269041-663.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.0 KB - Content
- 1739361333964-462.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.2 KB - Content
- 1739361367866-742.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.1 KB - Content