Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 / BMS Main 3Xdevice must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.6 +The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -13,12 +13,10 @@ 13 13 |Overall dimensions (length × width × height), mm|200 × 123 × 12 14 14 |Mounting dimensions (length × width), mm|194 × 114 15 15 |Mounting holes|M3 16 -|Headers type X1-X9|Hirose ZE05 17 -|Headers type X11-X14|Molex series Mocro-Fit 18 18 19 19 == Headers == 20 20 21 -The location and designation of connectors on the BMS Main 3 / BMS Main 3Xdevice are shown below.19 +The location and designation of connectors on the BMS Main 3 device are shown below. 22 22 23 23 (% contenteditable="false" tabindex="-1" %) 24 24 ((( ... ... @@ -100,7 +100,7 @@ 100 100 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 101 101 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 102 102 103 - If the BMS Main 3 / BMS Main 3Xdevice generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3/ BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.101 + If the BMS Main 3 device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 104 104 105 105 Connection diagram to the current loop: 106 106 ... ... @@ -199,20 +199,13 @@ 199 199 |**3**|**GND**|Ground 200 200 |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 201 201 202 -(% class="box infomessage" %) 203 -((( 204 -**Note:** 205 -RS-485-2 operates differently depending on used firmware: 200 +Connection diagram for BMS Logic devices: 206 206 207 -* **BMS Main 3X:** RS-485-2 bus is reserved; 208 -* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 202 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]] 209 209 210 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 211 -))) 212 - 213 213 === X10 – miniUSB connector === 214 214 215 -The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3Xdevice.206 +The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 216 216 217 217 === X11 – header for high-voltage bus before contactors (plus) === 218 218 ... ... @@ -296,7 +296,7 @@ 296 296 297 297 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 298 298 299 -The BMS Main 3 / BMS Main 3Xdevice implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.290 +The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 300 300 301 301 == Indicators == 302 302 ... ... @@ -340,7 +340,7 @@ 340 340 341 341 (% class="box warningmessage" %) 342 342 ((( 343 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.334 +Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Settings.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. 344 344 ))) 345 345 346 346 All operations to connect the device must be carried out with the supply voltage removed. ... ... @@ -353,5 +353,5 @@ 353 353 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 354 354 * Connect external devices (if necessary) to header X6. 355 355 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 356 -* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.347 +* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 357 357 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.