Last modified by Admin on 2025/03/18 12:51

From version 44.1
edited by Admin
on 2025/02/06 11:33
Change comment: There is no comment for this version
To version 38.1
edited by Admin
on 2024/12/12 16:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,7 +3,7 @@
3 3  
4 4  == Installation procedure ==
5 5  
6 -The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
6 +The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
7 7  
8 8  Overall and mounting dimensions are shown in figure below.
9 9  
... ... @@ -13,12 +13,10 @@
13 13  |Overall dimensions (length × width × height), mm|200 × 123 × 12
14 14  |Mounting dimensions (length × width), mm|194 × 114
15 15  |Mounting holes|M3
16 -|Connector type X1-X9|Hirose ZE05
17 -|Connector type X11-X14|Molex series Mocro-Fit
18 18  
19 19  == Headers ==
20 20  
21 -The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below.
19 +The location and designation of connectors on the BMS Main 3 device are shown below.
22 22  
23 23  (% contenteditable="false" tabindex="-1" %)
24 24  (((
... ... @@ -100,7 +100,7 @@
100 100  |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input)
101 101  |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA)
102 102  
103 - If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.
101 + If the BMS Main 3 device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.
104 104  
105 105  Connection diagram to the current loop:
106 106  
... ... @@ -184,8 +184,10 @@
184 184  CAN3 operates differently depending on used firmware:
185 185  
186 186  * **BMS Main 3:** CAN3 bus is reserved;
187 -* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus:
185 +* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings.
188 188  
187 +Diagram for connecting battery modules to the CAN3 bus:
188 +
189 189  [[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]]
190 190  )))
191 191  
... ... @@ -199,20 +199,13 @@
199 199  |**3**|**GND**|Ground
200 200  |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA)
201 201  
202 -(% class="box infomessage" %)
203 -(((
204 -**Note:**
205 -RS-485-2 operates differently depending on used firmware:
202 +Connection diagram for BMS Logic devices:
206 206  
207 -* **BMS Main 3X:** RS-485-2 bus is reserved;
208 -* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices:
204 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]]
209 209  
210 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]]
211 -)))
212 -
213 213  === X10 – miniUSB connector ===
214 214  
215 -The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device.
208 +The miniUSB connector is used to configure the parameters of the BMS Main 3 device.
216 216  
217 217  === X11 – header for high-voltage bus before contactors (plus) ===
218 218  
... ... @@ -296,7 +296,7 @@
296 296  
297 297  === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
298 298  
299 -The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
292 +The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
300 300  
301 301  == Indicators ==
302 302  
... ... @@ -340,7 +340,7 @@
340 340  
341 341  (% class="box warningmessage" %)
342 342  (((
343 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.
336 +Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Settings.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.
344 344  )))
345 345  
346 346  All operations to connect the device must be carried out with the supply voltage removed.
... ... @@ -353,5 +353,5 @@
353 353  * Connect the high-voltage network integrity circuit (if necessary) to header X4.
354 354  * Connect external devices (if necessary) to header X6.
355 355  * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7.
356 -* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.
349 +* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.
357 357  * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.