Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,22 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +(% class="box warningmessage" %) 11 +((( 12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 +))) 14 + 15 +(% class="box errormessage" %) 16 +((( 17 +**The system is not designed to operate with batteries whose total voltage exceeds 3000 V.** 18 +))) 19 + 4 4 == Installation procedure == 5 5 6 6 The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. ... ... @@ -13,7 +13,6 @@ 13 13 |Overall dimensions (length × width × height), mm|200 × 123 × 12 14 14 |Mounting dimensions (length × width), mm|194 × 114 15 15 |Mounting holes|M3 16 -|Connector type|Hirose ZE05 17 17 18 18 == Headers == 19 19 ... ... @@ -32,6 +32,8 @@ 32 32 33 33 === X1 – header to power the device === 34 34 50 +Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 51 + 35 35 (% class="wikigeneratedid" id="H" %) 36 36 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 37 37 ... ... @@ -47,6 +47,8 @@ 47 47 48 48 === X2 – header for contactors === 49 49 67 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 68 + 50 50 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 51 51 52 52 |**Pin**|**Name**|**Description** ... ... @@ -64,6 +64,8 @@ 64 64 65 65 === (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 66 66 86 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 87 + 67 67 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 68 68 69 69 |**Pin**|**Name**|**Description** ... ... @@ -89,8 +89,12 @@ 89 89 90 90 (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 91 91 113 +[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]] 114 + 92 92 === X4 – header for HVIL === 93 93 117 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 118 + 94 94 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 95 95 96 96 |**Pin**|**Name**|**Description** ... ... @@ -103,8 +103,12 @@ 103 103 104 104 Connection diagram to the current loop: 105 105 131 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 132 + 106 106 === X5 – header for current and temperature sensors === 107 107 135 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 136 + 108 108 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 109 109 110 110 (% style="width:539px" %) ... ... @@ -136,6 +136,8 @@ 136 136 137 137 === X6 – header for CAN1 and RS-485-1 (external buses) === 138 138 168 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 169 + 139 139 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 140 140 141 141 |**Pin**|**Name**|**Description** ... ... @@ -155,6 +155,8 @@ 155 155 156 156 === X7 – header for CAN2 (internal bus) === 157 157 189 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 190 + 158 158 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 159 159 160 160 |**Pin**|**Name**|**Description** ... ... @@ -169,6 +169,8 @@ 169 169 170 170 === X8 – header for CAN3 === 171 171 205 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 206 + 172 172 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 173 173 174 174 |**Pin**|**Name**|**Description** ... ... @@ -190,6 +190,8 @@ 190 190 191 191 === X9 – header for BMS Logic (RS-485-2) === 192 192 228 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 229 + 193 193 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 194 194 195 195 |**Pin**|**Name**|**Description** ... ... @@ -215,6 +215,8 @@ 215 215 216 216 === X11 – header for high-voltage bus before contactors (plus) === 217 217 255 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 256 + 218 218 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 219 219 220 220 |**Pin**|**Name**|**Description** ... ... @@ -228,6 +228,8 @@ 228 228 229 229 === X12 – header for high-voltage bus before contactors (minus) === 230 230 270 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 271 + 231 231 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 232 232 233 233 |**Pin**|**Name**|**Description** ... ... @@ -241,6 +241,8 @@ 241 241 242 242 === X13 – header for high-voltage bus after contactors (plus) === 243 243 285 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 286 + 244 244 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 245 245 246 246 |**Pin**|**Name**|**Description** ... ... @@ -254,6 +254,8 @@ 254 254 255 255 === X14 – header for high-voltage bus after contactors (minus) === 256 256 300 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 301 + 257 257 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 258 258 259 259 |**Pin**|**Name**|**Description** ... ... @@ -311,17 +311,19 @@ 311 311 |**Blinking green**|Executing the battery management program 312 312 |**No blinking**|Program execution error 313 313 314 -=== DS3 – LED indicating interaction with BMSLogic ===359 +=== DS3 – LED indicating interaction with child devices === 315 315 316 -|**State**|**Description** 317 -|**Blinking yellow**|The device interacts with BMS Logic devices 318 -|**No blinking**|- 361 +(% style="width:447px" %) 362 +|**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)** 363 +|**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices 364 +|**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)- 319 319 320 -=== DS4 – LED indicating loss of connection with BMS Logic ===366 +=== DS4 – LED indicating loss of connection with child devices === 321 321 322 -|**State**|**Description** 323 -|**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost 324 -|**No blinking**|Communication with BMS Logic is stable 368 +(% style="width:601px" %) 369 +|**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)** 370 +|**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost 371 +|**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable 325 325 326 326 === DS5-DS10 – LEDs indicating contactor switches 1-6 === 327 327 ... ... @@ -337,11 +337,6 @@ 337 337 338 338 == Connection procedure == 339 339 340 -(% class="box warningmessage" %) 341 -((( 342 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. 343 -))) 344 - 345 345 All operations to connect the device must be carried out with the supply voltage removed. 346 346 347 347 * Connect the power contactors to header X2.
- 1739361236606-576.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.8 KB - Content
- 1739361269041-663.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.0 KB - Content
- 1739361333964-462.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.2 KB - Content
- 1739361367866-742.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.1 KB - Content