... ... @@ -13,7 +13,6 @@
13 13  |Overall dimensions (length × width × height), mm|200 × 123 × 12
14 14  |Mounting dimensions (length × width), mm|194 × 114
15 15  |Mounting holes|M3
16 -|Connector type|Hirose ZE05
17 17  
18 18  == Headers ==
19 19  
... ... @@ -211,7 +211,7 @@
211 211  
212 212  === X10 – miniUSB connector ===
213 213  
214 -The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device.
213 +The miniUSB connector is used to configure the parameters of the BMS Main 3  device.
215 215  
216 216  === X11 – header for high-voltage bus before contactors (plus) ===
217 217  
... ... @@ -295,7 +295,7 @@
295 295  
296 296  === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
297 297  
298 -The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
297 +The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
299 299  
300 300  == Indicators ==
301 301  
... ... @@ -339,7 +339,7 @@
339 339  
340 340  (% class="box warningmessage" %)
341 341  (((
342 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.
341 +Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Settings.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.
343 343  )))
344 344  
345 345  All operations to connect the device must be carried out with the supply voltage removed.