Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,24 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, configure the system, see [[Configuration>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 + 12 +(% class="box warningmessage" %) 13 +((( 14 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 15 +))) 16 + 17 +(% class="box errormessage" %) 18 +((( 19 +**The system is not designed to operate with batteries whose total voltage exceeds 3000 V.** 20 +))) 21 + 4 4 == Installation procedure == 5 5 6 6 The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. ... ... @@ -31,6 +31,8 @@ 31 31 32 32 === X1 – header to power the device === 33 33 52 +Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 53 + 34 34 (% class="wikigeneratedid" id="H" %) 35 35 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 36 36 ... ... @@ -46,6 +46,8 @@ 46 46 47 47 === X2 – header for contactors === 48 48 69 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 70 + 49 49 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 50 50 51 51 |**Pin**|**Name**|**Description** ... ... @@ -63,6 +63,8 @@ 63 63 64 64 === (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 65 65 88 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 89 + 66 66 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 67 67 68 68 |**Pin**|**Name**|**Description** ... ... @@ -88,8 +88,12 @@ 88 88 89 89 (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 90 90 115 +[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]] 116 + 91 91 === X4 – header for HVIL === 92 92 119 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 120 + 93 93 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 94 94 95 95 |**Pin**|**Name**|**Description** ... ... @@ -102,8 +102,12 @@ 102 102 103 103 Connection diagram to the current loop: 104 104 133 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 134 + 105 105 === X5 – header for current and temperature sensors === 106 106 137 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 138 + 107 107 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 108 108 109 109 (% style="width:539px" %) ... ... @@ -135,6 +135,8 @@ 135 135 136 136 === X6 – header for CAN1 and RS-485-1 (external buses) === 137 137 170 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 171 + 138 138 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 139 139 140 140 |**Pin**|**Name**|**Description** ... ... @@ -154,6 +154,8 @@ 154 154 155 155 === X7 – header for CAN2 (internal bus) === 156 156 191 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 192 + 157 157 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 158 158 159 159 |**Pin**|**Name**|**Description** ... ... @@ -168,6 +168,8 @@ 168 168 169 169 === X8 – header for CAN3 === 170 170 207 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 208 + 171 171 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 172 172 173 173 |**Pin**|**Name**|**Description** ... ... @@ -189,6 +189,8 @@ 189 189 190 190 === X9 – header for BMS Logic (RS-485-2) === 191 191 230 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 231 + 192 192 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 193 193 194 194 |**Pin**|**Name**|**Description** ... ... @@ -214,6 +214,8 @@ 214 214 215 215 === X11 – header for high-voltage bus before contactors (plus) === 216 216 257 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 258 + 217 217 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 218 218 219 219 |**Pin**|**Name**|**Description** ... ... @@ -227,6 +227,8 @@ 227 227 228 228 === X12 – header for high-voltage bus before contactors (minus) === 229 229 272 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 273 + 230 230 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 231 231 232 232 |**Pin**|**Name**|**Description** ... ... @@ -240,6 +240,8 @@ 240 240 241 241 === X13 – header for high-voltage bus after contactors (plus) === 242 242 287 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 288 + 243 243 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 244 244 245 245 |**Pin**|**Name**|**Description** ... ... @@ -253,6 +253,8 @@ 253 253 254 254 === X14 – header for high-voltage bus after contactors (minus) === 255 255 302 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 303 + 256 256 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 257 257 258 258 |**Pin**|**Name**|**Description** ... ... @@ -310,17 +310,19 @@ 310 310 |**Blinking green**|Executing the battery management program 311 311 |**No blinking**|Program execution error 312 312 313 -=== DS3 – LED indicating interaction with BMSLogic ===361 +=== DS3 – LED indicating interaction with child devices === 314 314 315 -|**State**|**Description** 316 -|**Blinking yellow**|The device interacts with BMS Logic devices 317 -|**No blinking**|- 363 +(% style="width:447px" %) 364 +|**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)** 365 +|**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices 366 +|**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)- 318 318 319 -=== DS4 – LED indicating loss of connection with BMS Logic ===368 +=== DS4 – LED indicating loss of connection with child devices === 320 320 321 -|**State**|**Description** 322 -|**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost 323 -|**No blinking**|Communication with BMS Logic is stable 370 +(% style="width:601px" %) 371 +|**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)** 372 +|**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost 373 +|**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable 324 324 325 325 === DS5-DS10 – LEDs indicating contactor switches 1-6 === 326 326 ... ... @@ -336,6 +336,13 @@ 336 336 337 337 == Connection procedure == 338 338 389 +The BMS can connect to batteries with voltage levels dangerous to life and health. When working with high voltage batteries, follow electrical safety rules, use safety glasses, protective clothing, insulated tools and devices. 390 + 391 +(% class="box errormessage" %) 392 +((( 393 +**The system is not designed to operate with batteries with total voltage more than 3000V.** 394 +))) 395 + 339 339 (% class="box warningmessage" %) 340 340 ((( 341 341 Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.
- 1739361236606-576.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.8 KB - Content
- 1739361269041-663.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.0 KB - Content
- 1739361333964-462.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.2 KB - Content
- 1739361367866-742.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.1 KB - Content