Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 / BMS Main 3Xdevice must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.6 +The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -16,7 +16,7 @@ 16 16 17 17 == Headers == 18 18 19 -The location and designation of connectors on the BMS Main 3 / BMS Main 3Xdevice are shown below.19 +The location and designation of connectors on the BMS Main 3 device are shown below. 20 20 21 21 (% contenteditable="false" tabindex="-1" %) 22 22 ((( ... ... @@ -98,7 +98,7 @@ 98 98 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 99 99 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 100 100 101 - If the BMS Main 3 / BMS Main 3Xdevice generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3/ BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.101 + If the BMS Main 3 device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 102 102 103 103 Connection diagram to the current loop: 104 104 ... ... @@ -182,8 +182,10 @@ 182 182 CAN3 operates differently depending on used firmware: 183 183 184 184 * **BMS Main 3:** CAN3 bus is reserved; 185 -* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus:185 +* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. 186 186 187 +Diagram for connecting battery modules to the CAN3 bus: 188 + 187 187 [[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 188 188 ))) 189 189 ... ... @@ -197,20 +197,13 @@ 197 197 |**3**|**GND**|Ground 198 198 |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 199 199 200 -(% class="box infomessage" %) 201 -((( 202 -**Note:** 203 -RS-485-2 operates differently depending on used firmware: 202 +Connection diagram for BMS Logic devices: 204 204 205 -* **BMS Main 3X:** RS-485-2 bus is reserved; 206 -* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 204 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]] 207 207 208 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 209 -))) 210 - 211 211 === X10 – miniUSB connector === 212 212 213 -The miniUSB connector is used to configure the parameters of the BMS Main 3 208 +The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 214 214 215 215 === X11 – header for high-voltage bus before contactors (plus) === 216 216 ... ... @@ -351,5 +351,5 @@ 351 351 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 352 352 * Connect external devices (if necessary) to header X6. 353 353 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 354 -* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.349 +* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 355 355 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.