Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 6 +The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -16,7 +16,7 @@ 16 16 17 17 == Headers == 18 18 19 -The location and designation of connectors on the BMS Main 3 device are shown below. 19 +The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below. 20 20 21 21 (% contenteditable="false" tabindex="-1" %) 22 22 ((( ... ... @@ -98,7 +98,7 @@ 98 98 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 99 99 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 100 100 101 - If the BMS Main 3 device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 101 + If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 102 102 103 103 Connection diagram to the current loop: 104 104 ... ... @@ -182,10 +182,8 @@ 182 182 CAN3 operates differently depending on used firmware: 183 183 184 184 * **BMS Main 3:** CAN3 bus is reserved; 185 -* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. 185 +* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus: 186 186 187 -Diagram for connecting battery modules to the CAN3 bus: 188 - 189 189 [[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 190 190 ))) 191 191 ... ... @@ -199,13 +199,20 @@ 199 199 |**3**|**GND**|Ground 200 200 |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 201 201 202 -Connection diagram for BMS Logic devices: 200 +(% class="box infomessage" %) 201 +((( 202 +**Note:** 203 +RS-485-2 operates differently depending on used firmware: 203 203 204 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]] 205 +* **BMS Main 3X:** RS-485-2 bus is reserved; 206 +* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 205 205 208 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 209 +))) 210 + 206 206 === X10 – miniUSB connector === 207 207 208 -The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 213 +The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 209 209 210 210 === X11 – header for high-voltage bus before contactors (plus) === 211 211 ... ... @@ -346,5 +346,5 @@ 346 346 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 347 347 * Connect external devices (if necessary) to header X6. 348 348 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 349 -* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 354 +* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 350 350 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.