Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 6 +The mounting location of the BMS Main 3.0 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -16,7 +16,7 @@ 16 16 17 17 == Headers == 18 18 19 -The location and designation of connectors on the BMS Main 3 device are shown below. 19 +The location and designation of connectors on the BMS Main 3.0 device are shown below. 20 20 21 21 (% contenteditable="false" tabindex="-1" %) 22 22 ((( ... ... @@ -157,8 +157,8 @@ 157 157 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 158 158 159 159 |**Pin**|**Name**|**Description** 160 -|**1**|**CAN2_H**|CAN2 line H for communication with otherBMS devices161 -|**2**|**CAN2_L**|CAN2 line L for communication with otherBMS devices160 +|**1**|**CAN2_H**|CAN2 line H for communication with BMS devices 161 +|**2**|**CAN2_L**|CAN2 line L for communication with BMS devices 162 162 |**3**|**GND**|Ground 163 163 |**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA) 164 164 ... ... @@ -171,23 +171,19 @@ 171 171 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 172 172 173 173 |**Pin**|**Name**|**Description** 174 -|**1**|**CAN3_H**|CAN3 line H 175 -|**2**|**CAN3_L**|CAN3 line L 174 +|**1**|**CAN3_H**|CAN3 line H for communication with battery modules (for BMS Main 3X) 175 +|**2**|**CAN3_L**|CAN3 line L for communication with battery modules (for BMS Main 3X) 176 176 |**3**|**GND**|Ground 177 177 |**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA) 178 178 179 179 (% class="box infomessage" %) 180 180 ((( 181 - **Note:**182 - CAN3 operates differently depending on used firmware:181 +If the BMS Main 3 device acts as a controller for a battery system consisting of several battery modules connected in parallel, then the parallel battery BMS must be connected to the CAN3 bus. 182 +))) 183 183 184 -* **BMS Main 3:** CAN3 bus is reserved; 185 -* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. 186 - 187 187 Diagram for connecting battery modules to the CAN3 bus: 188 188 189 -[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 190 -))) 186 +[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" height="153" width="417"]] 191 191 192 192 === X9 – header for BMS Logic (RS-485-2) === 193 193 ... ... @@ -205,7 +205,7 @@ 205 205 206 206 === X10 – miniUSB connector === 207 207 208 -The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 204 +The miniUSB connector is used to configure the parameters of the BMS Main 3.0 device. 209 209 210 210 === X11 – header for high-voltage bus before contactors (plus) === 211 211 ... ... @@ -346,5 +346,5 @@ 346 346 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 347 347 * Connect external devices (if necessary) to header X6. 348 348 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 349 -* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 345 +* If the BMS Main 3.0 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 350 350 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.