Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 6 +The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -13,10 +13,11 @@ 13 13 |Overall dimensions (length × width × height), mm|200 × 123 × 12 14 14 |Mounting dimensions (length × width), mm|194 × 114 15 15 |Mounting holes|M3 16 +|Connector type|Hirose ZE05 16 16 17 17 == Headers == 18 18 19 -The location and designation of connectors on the BMS Main 3 device are shown below. 20 +The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below. 20 20 21 21 (% contenteditable="false" tabindex="-1" %) 22 22 ((( ... ... @@ -98,7 +98,7 @@ 98 98 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 99 99 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 100 100 101 - If the BMS Main 3 device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 102 + If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 102 102 103 103 Connection diagram to the current loop: 104 104 ... ... @@ -157,8 +157,8 @@ 157 157 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 158 158 159 159 |**Pin**|**Name**|**Description** 160 -|**1**|**CAN2_H**|CAN2 line H for communication with BMS devices 161 -|**2**|**CAN2_L**|CAN2 line L for communication with BMS devices 161 +|**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices 162 +|**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices 162 162 |**3**|**GND**|Ground 163 163 |**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA) 164 164 ... ... @@ -171,19 +171,21 @@ 171 171 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 172 172 173 173 |**Pin**|**Name**|**Description** 174 -|**1**|**CAN3_H**|CAN3 line H for communication with battery modules (for BMS Main 3X)175 -|**2**|**CAN3_L**|CAN3 line L for communication with battery modules (for BMS Main 3X)175 +|**1**|**CAN3_H**|CAN3 line H 176 +|**2**|**CAN3_L**|CAN3 line L 176 176 |**3**|**GND**|Ground 177 177 |**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA) 178 178 179 179 (% class="box infomessage" %) 180 180 ((( 181 - If the BMS Main 3 device acts as a controller for a battery system consisting of several battery modules connected in parallel, then the parallel battery BMS must be connected to the CAN3 bus.182 - )))182 +**Note:** 183 +CAN3 operates differently depending on used firmware: 183 183 184 -Diagram for connecting battery modules to the CAN3 bus: 185 +* **BMS Main 3:** CAN3 bus is reserved; 186 +* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus: 185 185 186 -[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" height="153" width="417"]] 188 +[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 189 +))) 187 187 188 188 === X9 – header for BMS Logic (RS-485-2) === 189 189 ... ... @@ -195,13 +195,20 @@ 195 195 |**3**|**GND**|Ground 196 196 |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 197 197 198 -Connection diagram for BMS Logic devices: 201 +(% class="box infomessage" %) 202 +((( 203 +**Note:** 204 +RS-485-2 operates differently depending on used firmware: 199 199 200 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]] 206 +* **BMS Main 3X:** RS-485-2 bus is reserved; 207 +* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 201 201 209 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 210 +))) 211 + 202 202 === X10 – miniUSB connector === 203 203 204 -The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 214 +The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device. 205 205 206 206 === X11 – header for high-voltage bus before contactors (plus) === 207 207 ... ... @@ -285,7 +285,7 @@ 285 285 286 286 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 287 287 288 -The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 298 +The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 289 289 290 290 == Indicators == 291 291 ... ... @@ -329,7 +329,7 @@ 329 329 330 330 (% class="box warningmessage" %) 331 331 ((( 332 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Settings.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.342 +Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. 333 333 ))) 334 334 335 335 All operations to connect the device must be carried out with the supply voltage removed. ... ... @@ -342,5 +342,5 @@ 342 342 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 343 343 * Connect external devices (if necessary) to header X6. 344 344 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 345 -* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 355 +* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 346 346 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.