Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 .0device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.6 +The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -16,7 +16,7 @@ 16 16 17 17 == Headers == 18 18 19 -The location and designation of connectors on the BMS Main 3 .0device are shown below.19 +The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below. 20 20 21 21 (% contenteditable="false" tabindex="-1" %) 22 22 ((( ... ... @@ -31,6 +31,8 @@ 31 31 32 32 === X1 – header to power the device === 33 33 34 +Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 35 + 34 34 (% class="wikigeneratedid" id="H" %) 35 35 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 36 36 ... ... @@ -46,6 +46,8 @@ 46 46 47 47 === X2 – header for contactors === 48 48 51 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 52 + 49 49 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 50 50 51 51 |**Pin**|**Name**|**Description** ... ... @@ -63,6 +63,8 @@ 63 63 64 64 === (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 65 65 70 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 71 + 66 66 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 67 67 68 68 |**Pin**|**Name**|**Description** ... ... @@ -88,8 +88,12 @@ 88 88 89 89 (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 90 90 97 +[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]] 98 + 91 91 === X4 – header for HVIL === 92 92 101 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 102 + 93 93 [[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 94 94 95 95 |**Pin**|**Name**|**Description** ... ... @@ -98,12 +98,16 @@ 98 98 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 99 99 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 100 100 101 - If the BMS Main 3 device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 111 + If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 102 102 103 103 Connection diagram to the current loop: 104 104 115 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 116 + 105 105 === X5 – header for current and temperature sensors === 106 106 119 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 120 + 107 107 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 108 108 109 109 (% style="width:539px" %) ... ... @@ -135,6 +135,8 @@ 135 135 136 136 === X6 – header for CAN1 and RS-485-1 (external buses) === 137 137 152 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 153 + 138 138 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 139 139 140 140 |**Pin**|**Name**|**Description** ... ... @@ -154,11 +154,13 @@ 154 154 155 155 === X7 – header for CAN2 (internal bus) === 156 156 173 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 174 + 157 157 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 158 158 159 159 |**Pin**|**Name**|**Description** 160 -|**1**|**CAN2_H**|CAN2 line H for communication with BMS devices 161 -|**2**|**CAN2_L**|CAN2 line L for communication with BMS devices 178 +|**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices 179 +|**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices 162 162 |**3**|**GND**|Ground 163 163 |**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA) 164 164 ... ... @@ -168,25 +168,31 @@ 168 168 169 169 === X8 – header for CAN3 === 170 170 189 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 190 + 171 171 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 172 172 173 173 |**Pin**|**Name**|**Description** 174 -|**1**|**CAN3_H**|CAN3 line H for communication with battery modules (for BMS Main 3X)175 -|**2**|**CAN3_L**|CAN3 line L for communication with battery modules (for BMS Main 3X)194 +|**1**|**CAN3_H**|CAN3 line H 195 +|**2**|**CAN3_L**|CAN3 line L 176 176 |**3**|**GND**|Ground 177 177 |**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA) 178 178 179 179 (% class="box infomessage" %) 180 180 ((( 181 - If the BMS Main 3 device acts as a controller for a battery system consisting of several battery modules connected in parallel, then the parallel battery BMS must be connected to the CAN3 bus.182 - )))201 +**Note:** 202 +CAN3 operates differently depending on used firmware: 183 183 184 -Diagram for connecting battery modules to the CAN3 bus: 204 +* **BMS Main 3:** CAN3 bus is reserved; 205 +* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus: 185 185 186 -[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" height="153" width="417"]] 207 +[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 208 +))) 187 187 188 188 === X9 – header for BMS Logic (RS-485-2) === 189 189 212 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 213 + 190 190 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 191 191 192 192 |**Pin**|**Name**|**Description** ... ... @@ -195,16 +195,25 @@ 195 195 |**3**|**GND**|Ground 196 196 |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 197 197 198 -Connection diagram for BMS Logic devices: 222 +(% class="box infomessage" %) 223 +((( 224 +**Note:** 225 +RS-485-2 operates differently depending on used firmware: 199 199 200 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]] 227 +* **BMS Main 3X:** RS-485-2 bus is reserved; 228 +* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 201 201 230 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 231 +))) 232 + 202 202 === X10 – miniUSB connector === 203 203 204 -The miniUSB connector is used to configure the parameters of the BMS Main 3 .0device.235 +The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device. 205 205 206 206 === X11 – header for high-voltage bus before contactors (plus) === 207 207 239 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 240 + 208 208 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 209 209 210 210 |**Pin**|**Name**|**Description** ... ... @@ -218,6 +218,8 @@ 218 218 219 219 === X12 – header for high-voltage bus before contactors (minus) === 220 220 254 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 255 + 221 221 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 222 222 223 223 |**Pin**|**Name**|**Description** ... ... @@ -231,6 +231,8 @@ 231 231 232 232 === X13 – header for high-voltage bus after contactors (plus) === 233 233 269 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 270 + 234 234 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 235 235 236 236 |**Pin**|**Name**|**Description** ... ... @@ -244,6 +244,8 @@ 244 244 245 245 === X14 – header for high-voltage bus after contactors (minus) === 246 246 284 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 285 + 247 247 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 248 248 249 249 |**Pin**|**Name**|**Description** ... ... @@ -285,7 +285,7 @@ 285 285 286 286 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 287 287 288 -The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 327 +The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 289 289 290 290 == Indicators == 291 291 ... ... @@ -301,17 +301,19 @@ 301 301 |**Blinking green**|Executing the battery management program 302 302 |**No blinking**|Program execution error 303 303 304 -=== DS3 – LED indicating interaction with BMSLogic ===343 +=== DS3 – LED indicating interaction with child devices === 305 305 306 -|**State**|**Description** 307 -|**Blinking yellow**|The device interacts with BMS Logic devices 308 -|**No blinking**|- 345 +(% style="width:447px" %) 346 +|**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)** 347 +|**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices 348 +|**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)- 309 309 310 -=== DS4 – LED indicating loss of connection with BMS Logic ===350 +=== DS4 – LED indicating loss of connection with child devices === 311 311 312 -|**State**|**Description** 313 -|**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost 314 -|**No blinking**|Communication with BMS Logic is stable 352 +(% style="width:601px" %) 353 +|**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)** 354 +|**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost 355 +|**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable 315 315 316 316 === DS5-DS10 – LEDs indicating contactor switches 1-6 === 317 317 ... ... @@ -327,9 +327,16 @@ 327 327 328 328 == Connection procedure == 329 329 371 +The BMS can connect to batteries with voltage levels dangerous to life and health. When working with high voltage batteries, follow electrical safety rules, use safety glasses, protective clothing, insulated tools and devices. 372 + 373 +(% class="box errormessage" %) 374 +((( 375 +**The system is not designed to operate with batteries with total voltage more than 3000V.** 376 +))) 377 + 330 330 (% class="box warningmessage" %) 331 331 ((( 332 -Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Settings.WebHome]]). Correct operation of the BMS system is only possible with correct configuration.380 +Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Configuration.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. 333 333 ))) 334 334 335 335 All operations to connect the device must be carried out with the supply voltage removed. ... ... @@ -342,5 +342,5 @@ 342 342 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 343 343 * Connect external devices (if necessary) to header X6. 344 344 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 345 -* If the BMS Main 3 .0is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.393 +* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 346 346 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.
- 1739361236606-576.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.8 KB - Content
- 1739361269041-663.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.0 KB - Content
- 1739361333964-462.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.2 KB - Content
- 1739361367866-742.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.1 KB - Content