Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 .0device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.6 +The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -16,7 +16,7 @@ 16 16 17 17 == Headers == 18 18 19 -The location and designation of connectors on the BMS Main 3 .0device are shown below.19 +The location and designation of connectors on the BMS Main 3 device are shown below. 20 20 21 21 (% contenteditable="false" tabindex="-1" %) 22 22 ((( ... ... @@ -157,8 +157,8 @@ 157 157 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 158 158 159 159 |**Pin**|**Name**|**Description** 160 -|**1**|**CAN2_H**|CAN2 line H for communication with BMS devices 161 -|**2**|**CAN2_L**|CAN2 line L for communication with BMS devices 160 +|**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices 161 +|**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices 162 162 |**3**|**GND**|Ground 163 163 |**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA) 164 164 ... ... @@ -171,19 +171,21 @@ 171 171 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 172 172 173 173 |**Pin**|**Name**|**Description** 174 -|**1**|**CAN3_H**|CAN3 line H for communication with battery modules (for BMS Main 3X)175 -|**2**|**CAN3_L**|CAN3 line L for communication with battery modules (for BMS Main 3X)174 +|**1**|**CAN3_H**|CAN3 line H 175 +|**2**|**CAN3_L**|CAN3 line L 176 176 |**3**|**GND**|Ground 177 177 |**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA) 178 178 179 179 (% class="box infomessage" %) 180 180 ((( 181 - If the BMS Main 3 device acts as a controller for a battery system consisting of several battery modules connected in parallel, then the parallel battery BMS must be connected to the CAN3 bus.182 - )))181 +**Note:** 182 +CAN3 operates differently depending on used firmware: 183 183 184 -Diagram for connecting battery modules to the CAN3 bus: 184 +* **BMS Main 3:** CAN3 bus is reserved; 185 +* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus: 185 185 186 -[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" height="153" width="417"]] 187 +[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 188 +))) 187 187 188 188 === X9 – header for BMS Logic (RS-485-2) === 189 189 ... ... @@ -201,7 +201,7 @@ 201 201 202 202 === X10 – miniUSB connector === 203 203 204 -The miniUSB connector is used to configure the parameters of the BMS Main 3 .0device.206 +The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 205 205 206 206 === X11 – header for high-voltage bus before contactors (plus) === 207 207 ... ... @@ -342,5 +342,5 @@ 342 342 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 343 343 * Connect external devices (if necessary) to header X6. 344 344 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 345 -* If the BMS Main 3 .0is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.347 +* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 346 346 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.