Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,7 @@ 3 3 4 4 == Installation procedure == 5 5 6 -The mounting location of the BMS Main 3 .0device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.6 +The mounting location of the BMS Main 3 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 7 7 8 8 Overall and mounting dimensions are shown in figure below. 9 9 ... ... @@ -16,7 +16,7 @@ 16 16 17 17 == Headers == 18 18 19 -The location and designation of connectors on the BMS Main 3 .0device are shown below.19 +The location and designation of connectors on the BMS Main 3 device are shown below. 20 20 21 21 (% contenteditable="false" tabindex="-1" %) 22 22 ((( ... ... @@ -201,7 +201,7 @@ 201 201 202 202 === X10 – miniUSB connector === 203 203 204 -The miniUSB connector is used to configure the parameters of the BMS Main 3 .0device.204 +The miniUSB connector is used to configure the parameters of the BMS Main 3 device. 205 205 206 206 === X11 – header for high-voltage bus before contactors (plus) === 207 207 ... ... @@ -342,5 +342,5 @@ 342 342 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 343 343 * Connect external devices (if necessary) to header X6. 344 344 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 345 -* If the BMS Main 3 .0is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.345 +* If the BMS Main 3 is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 346 346 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.