... ... @@ -1,6 +1,5 @@
1 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Installation and connection =
3 -
1 +(% data-numbered-headings-start="1" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0)" %)
2 += =
4 4  == Installation procedure ==
5 5  
6 6  The mounting location of the BMS Main 3.0 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
... ... @@ -14,7 +14,7 @@
14 14  |Mounting dimensions (length × width), mm|194 × 114
15 15  |Mounting holes|M3
16 16  
17 -== Headers ==
16 +== 2.2 Headers ==
18 18  
19 19  The location and designation of connectors on the BMS Main 3.0 device are shown below.
20 20  
... ... @@ -29,7 +29,7 @@
29 29  All headers are shown from the device side!
30 30  )))
31 31  
32 -=== X1 – header to power the device ===
31 +=== 2.2.1 X1 – header to power the device ===
33 33  
34 34  (% class="wikigeneratedid" id="H" %)
35 35  (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]]
... ... @@ -44,7 +44,7 @@
44 44  
45 45  (% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]]
46 46  
47 -=== X2 – header for contactors ===
46 +=== (% title="Click and drag to resize" %)​(%%)2.2.2 X2 – header for contactors ===
48 48  
49 49  (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %)​
50 50  
... ... @@ -61,7 +61,7 @@
61 61  
62 62  (% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]]
63 63  
64 -=== (% title="Click and drag to resize" %)​(%%)X3 – header for discrete inputs and outputs ===
63 +=== (% title="Click and drag to resize" %)​(%%)2.2.3 X3 – header for discrete inputs and outputs ===
65 65  
66 66  (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]]
67 67  
... ... @@ -88,9 +88,9 @@
88 88  
89 89  (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)​(%%)Connection diagram for discrete output:
90 90  
91 -=== X4 – header for HVIL ===
90 + (% aria-label="1732121942791-517.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121942791-517.png||data-xwiki-image-style-alignment="center" height="90" width="269"]](% title="Click and drag to resize" %)​(% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)2.2.4 X4 – header for HVIL
92 92  
93 -[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]]
92 +(% aria-label="1732122015188-642.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]](% title="Click and drag to resize" %)​
94 94  
95 95  |**Pin**|**Name**|**Description**
96 96  |**1**|**-**|Not used
... ... @@ -102,9 +102,9 @@
102 102  
103 103  Connection diagram to the current loop:
104 104  
105 -=== X5 – header for current and temperature sensors ===
104 +(% aria-label="1732122067418-263.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122067418-263.png||data-xwiki-image-style-alignment="center" height="264" width="356"]](% title="Click and drag to resize" %)​(% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)2.2.5 X5 – header for current and temperature sensors
106 106  
107 -[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]]
106 +(% aria-label="image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]](% title="Click and drag to resize" %)​
108 108  
109 109  (% style="width:539px" %)
110 110  |**Pin**|**Name**|(% style="width:402px" %)**Description**
... ... @@ -133,7 +133,7 @@
133 133  
134 134  [[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]]
135 135  
136 -=== X6 – header for CAN1 and RS-485-1 (external buses) ===
135 +=== 2.2.6 X6 – header for CAN1 and RS-485-1 (external buses) ===
137 137  
138 138  [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]]
139 139  
... ... @@ -152,7 +152,7 @@
152 152  
153 153  [[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]]
154 154  
155 -=== X7 – header for CAN2 (internal bus) ===
154 +=== 2.2.7 X7 – header for CAN2 (internal bus) ===
156 156  
157 157  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
158 158  
... ... @@ -166,7 +166,7 @@
166 166  
167 167  [[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]]
168 168  
169 -=== X8 – header for CAN3 ===
168 +=== 2.2.8 X8 – header for CAN3 ===
170 170  
171 171  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
172 172  
... ... @@ -185,7 +185,7 @@
185 185  
186 186  [[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" height="153" width="417"]]
187 187  
188 -=== X9 – header for BMS Logic (RS-485-2) ===
187 +=== 2.2.9 X9 – header for BMS Logic (RS-485-2) ===
189 189  
190 190  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
191 191  
... ... @@ -199,11 +199,11 @@
199 199  
200 200  [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]]
201 201  
202 -=== X10 – miniUSB connector ===
201 +=== 2.2.10 X10 – miniUSB connector ===
203 203  
204 204  The miniUSB connector is used to configure the parameters of the BMS Main 3.0 device.
205 205  
206 -=== X11 – header for high-voltage bus before contactors (plus) ===
205 +=== 2.2.11 X11 – header for high-voltage bus before contactors (plus) ===
207 207  
208 208  [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
209 209  
... ... @@ -216,7 +216,7 @@
216 216  The connected voltage must not exceed 1000V.
217 217  )))
218 218  
219 -=== X12 – header for high-voltage bus before contactors (minus) ===
218 +=== 2.2.12 X12 – header for high-voltage bus before contactors (minus) ===
220 220  
221 221  [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
222 222  
... ... @@ -229,7 +229,7 @@
229 229  The connected voltage must not exceed 1000V.
230 230  )))
231 231  
232 -=== X13 – header for high-voltage bus after contactors (plus) ===
231 +=== 2.2.13 X13 – header for high-voltage bus after contactors (plus) ===
233 233  
234 234  [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
235 235  
... ... @@ -242,7 +242,7 @@
242 242  The connected voltage must not exceed 1000V.
243 243  )))
244 244  
245 -=== X14 – header for high-voltage bus after contactors (minus) ===
244 +=== 2.2.14  X14 – header for high-voltage bus after contactors (minus) ===
246 246  
247 247  [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
248 248  
... ... @@ -255,7 +255,7 @@
255 255  The connected voltage must not exceed 1000V.
256 256  )))
257 257  
258 -=== J1 – jumper for switching RS-485-1 bus terminal resistor ===
257 +=== 2.2.15 J1 – jumper for switching RS-485-1 bus terminal resistor ===
259 259  
260 260  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
261 261  
... ... @@ -265,7 +265,7 @@
265 265  |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected
266 266  |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected
267 267  
268 -=== J2 – jumper for switching CAN1 bus terminal resistor ===
267 +=== 2.2.16 J2 – jumper for switching CAN1 bus terminal resistor ===
269 269  
270 270  
271 271  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table:
... ... @@ -274,7 +274,7 @@
274 274  |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected
275 275  |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected
276 276  
277 -=== J3 – jumper for switching CAN2 bus terminal resistor ===
276 +=== 2.2.17 J3 – jumper for switching CAN2 bus terminal resistor ===
278 278  
279 279  
280 280  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H** and **CAN2_L** lines, install a jumper. The jumper is installed according to the table:
... ... @@ -283,49 +283,49 @@
283 283  |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN2 bus is connected
284 284  |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN2 bus is disconnected
285 285  
286 -=== J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
285 +=== 2.2.18 J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
287 287  
288 288  The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
289 289  
290 -== Indicators ==
289 +== 2.3 Indicators ==
291 291  
292 -=== DS1 – LED indicating device power ===
291 +=== 2.3.1 DS1 – LED indicating device power ===
293 293  
294 294  |**State**|**Description**
295 295  |**Lights up green**|Device power (+5V) is present
296 296  |**Doesn’t light up**|No device power
297 297  
298 -=== DS2 – LED indicating device work ===
297 +=== 2.3.2 DS2 – LED indicating device work ===
299 299  
300 300  |**State**|**Description**
301 301  |**Blinking green**|Executing the battery management program
302 302  |**No blinking**|Program execution error
303 303  
304 -=== DS3 – LED indicating interaction with BMS Logic ===
303 +=== 2.3.3 DS3 – LED indicating interaction with BMS Logic ===
305 305  
306 306  |**State**|**Description**
307 307  |**Blinking yellow**|The device interacts with BMS Logic devices
308 308  |**No blinking**|-
309 309  
310 -=== DS4 – LED indicating loss of connection with BMS Logic ===
309 +=== 2.3.4 DS4 – LED indicating loss of connection with BMS Logic ===
311 311  
312 312  |**State**|**Description**
313 313  |**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost
314 314  |**No blinking**|Communication with BMS Logic is stable
315 315  
316 -=== DS5-DS10 – LEDs indicating contactor switches 1-6 ===
315 +=== 2.3.5 DS5-DS10 – LEDs indicating contactor switches 1-6 ===
317 317  
318 318  |**State**|**Description**
319 319  |**Lights up green**|The switch supplies voltage to the contactor winding
320 320  |**Doesn’t light up**|The switch doesn’t supply voltage to the contactor winding
321 321  
322 -=== DS11 – LED indicating the presence of power supply for contactors ===
321 +=== 2.3.6 DS11 – LED indicating the presence of power supply for contactors ===
323 323  
324 324  |**State**|**Description**
325 325  |**Lights up green**|Power supply for contactor switches (9-32V) is present
326 326  |**Doesn’t light up**|Power supply for contactor switches (9-32V) is not present
327 327  
328 -== Connection procedure ==
327 +== 2.4 Connection procedure ==
329 329  
330 330  (% class="box warningmessage" %)
331 331  (((