Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.bms-main-3.WebHome1 +Battery management systems.BMS Main 3.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 -(% data-numbered-headings-start=" 1" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0)" %)2 -= = 1 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Installation and connection = 3 3 4 4 == Installation procedure == 5 5 ... ... @@ -67,12 +67,12 @@ 67 67 68 68 |**Pin**|**Name**|**Description** 69 69 |**1–8, 12, 16–17, 21**|**DIO_GND**|Ground of input and output signals 70 -|**9**|**DIN1_SIGNAL**|Discrete input 1 “dry contact” (+5 V)71 -|**10**|**DIN2_SIGNAL**|Discrete input 2 “dry contact” (+5 V)72 -|**11**|**DIN3_SIGNAL**|Discrete input 3 “dry contact” (+5 V)73 -|**13**|**DIN4_SIGNAL**|Discrete input 4 “dry contact” (+5 V)74 -|**14**|**DIN5_SIGNAL**|Discrete input 5 “dry contact” (+5 V)75 -|**15**|**DIN6_SIGNAL**|Discrete input 6 “dry contact” (+5 V)70 +|**9**|**DIN1_SIGNAL**|Discrete input 1 “dry contact” 71 +|**10**|**DIN2_SIGNAL**|Discrete input 2 “dry contact” 72 +|**11**|**DIN3_SIGNAL**|Discrete input 3 “dry contact” 73 +|**13**|**DIN4_SIGNAL**|Discrete input 4 “dry contact” 74 +|**14**|**DIN5_SIGNAL**|Discrete input 5 “dry contact” 75 +|**15**|**DIN6_SIGNAL**|Discrete input 6 “dry contact” 76 76 |**18**|**DIN7_VIN**|Discrete input 7 (signal detection with voltage 9-32V) 77 77 |**19**|**DIN8_VIN**|Discrete input 8 (signal detection with voltage 9-32V) 78 78 |**20**|**DOUT1_OD**|Discrete output 1 “open drain” (60 V, 1A) ... ... @@ -102,7 +102,7 @@ 102 102 103 103 Connection diagram to the current loop: 104 104 105 -=== 105 +=== X5 – header for current and temperature sensors === 106 106 107 107 [[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 108 108 ... ... @@ -329,7 +329,7 @@ 329 329 330 330 (% class="box warningmessage" %) 331 331 ((( 332 -Before connection, configure the device (see ). Correct operation of the BMS system is only possible with correct configuration. 332 +Before connection, configure the device (see [[Settings>>doc:Battery management systems.BMS Main 3.3\. Settings.WebHome]]). Correct operation of the BMS system is only possible with correct configuration. 333 333 ))) 334 334 335 335 All operations to connect the device must be carried out with the supply voltage removed.