Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,5 @@ 1 1 (% data-numbered-headings-start="1" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0)" %) 2 2 = = 3 - 4 4 == Installation procedure == 5 5 6 6 The mounting location of the BMS Main 3.0 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. ... ... @@ -14,7 +14,7 @@ 14 14 |Mounting dimensions (length × width), mm|194 × 114 15 15 |Mounting holes|M3 16 16 17 -== Headers == 16 +== 2.2 Headers == 18 18 19 19 The location and designation of connectors on the BMS Main 3.0 device are shown below. 20 20 ... ... @@ -29,7 +29,7 @@ 29 29 All headers are shown from the device side! 30 30 ))) 31 31 32 -=== X1 – header to power the device === 31 +=== 2.2.1 X1 – header to power the device === 33 33 34 34 (% class="wikigeneratedid" id="H" %) 35 35 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] ... ... @@ -44,7 +44,7 @@ 44 44 45 45 (% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]] 46 46 47 -=== X2 – header for contactors === 46 +=== (% title="Click and drag to resize" %)(%%)2.2.2 X2 – header for contactors === 48 48 49 49 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 50 50 ... ... @@ -61,7 +61,7 @@ 61 61 62 62 (% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]] 63 63 64 -=== (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 63 +=== (% title="Click and drag to resize" %)(%%)2.2.3 X3 – header for discrete inputs and outputs === 65 65 66 66 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 67 67 ... ... @@ -88,9 +88,9 @@ 88 88 89 89 (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 90 90 91 -=== X4 – header for HVIL ===90 + (% aria-label="1732121942791-517.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121942791-517.png||data-xwiki-image-style-alignment="center" height="90" width="269"]](% title="Click and drag to resize" %)(% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)2.2.4 X4 – header for HVIL 92 92 93 -[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 92 +(% aria-label="1732122015188-642.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]](% title="Click and drag to resize" %) 94 94 95 95 |**Pin**|**Name**|**Description** 96 96 |**1**|**-**|Not used ... ... @@ -102,9 +102,9 @@ 102 102 103 103 Connection diagram to the current loop: 104 104 105 -=== X5 – header for current and temperature sensors ===104 +(% aria-label="1732122067418-263.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122067418-263.png||data-xwiki-image-style-alignment="center" height="264" width="356"]](% title="Click and drag to resize" %)(% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)2.2.5 X5 – header for current and temperature sensors 106 106 107 -[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 106 +(% aria-label="image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]](% title="Click and drag to resize" %) 108 108 109 109 (% style="width:539px" %) 110 110 |**Pin**|**Name**|(% style="width:402px" %)**Description** ... ... @@ -133,7 +133,7 @@ 133 133 134 134 [[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]] 135 135 136 -=== X6 – header for CAN1 and RS-485-1 (external buses) === 135 +=== 2.2.6 X6 – header for CAN1 and RS-485-1 (external buses) === 137 137 138 138 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 139 139 ... ... @@ -152,7 +152,7 @@ 152 152 153 153 [[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]] 154 154 155 -=== X7 – header for CAN2 (internal bus) === 154 +=== 2.2.7 X7 – header for CAN2 (internal bus) === 156 156 157 157 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 158 158 ... ... @@ -166,7 +166,7 @@ 166 166 167 167 [[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]] 168 168 169 -=== X8 – header for CAN3 === 168 +=== 2.2.8 X8 – header for CAN3 === 170 170 171 171 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 172 172 ... ... @@ -185,7 +185,7 @@ 185 185 186 186 [[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" height="153" width="417"]] 187 187 188 -=== X9 – header for BMS Logic (RS-485-2) === 187 +=== 2.2.9 X9 – header for BMS Logic (RS-485-2) === 189 189 190 190 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 191 191 ... ... @@ -199,11 +199,11 @@ 199 199 200 200 [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]] 201 201 202 -=== X10 – miniUSB connector === 201 +=== 2.2.10 X10 – miniUSB connector === 203 203 204 204 The miniUSB connector is used to configure the parameters of the BMS Main 3.0 device. 205 205 206 -=== X11 – header for high-voltage bus before contactors (plus) === 205 +=== 2.2.11 X11 – header for high-voltage bus before contactors (plus) === 207 207 208 208 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 209 209 ... ... @@ -216,7 +216,7 @@ 216 216 The connected voltage must not exceed 1000V. 217 217 ))) 218 218 219 -=== X12 – header for high-voltage bus before contactors (minus) === 218 +=== 2.2.12 X12 – header for high-voltage bus before contactors (minus) === 220 220 221 221 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 222 222 ... ... @@ -229,7 +229,7 @@ 229 229 The connected voltage must not exceed 1000V. 230 230 ))) 231 231 232 -=== X13 – header for high-voltage bus after contactors (plus) === 231 +=== 2.2.13 X13 – header for high-voltage bus after contactors (plus) === 233 233 234 234 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 235 235 ... ... @@ -242,7 +242,7 @@ 242 242 The connected voltage must not exceed 1000V. 243 243 ))) 244 244 245 -=== X14 – header for high-voltage bus after contactors (minus) === 244 +=== 2.2.14 X14 – header for high-voltage bus after contactors (minus) === 246 246 247 247 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 248 248 ... ... @@ -255,7 +255,7 @@ 255 255 The connected voltage must not exceed 1000V. 256 256 ))) 257 257 258 -=== J1 – jumper for switching RS-485-1 bus terminal resistor === 257 +=== 2.2.15 J1 – jumper for switching RS-485-1 bus terminal resistor === 259 259 260 260 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 261 261 ... ... @@ -265,7 +265,7 @@ 265 265 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected 266 266 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected 267 267 268 -=== J2 – jumper for switching CAN1 bus terminal resistor === 267 +=== 2.2.16 J2 – jumper for switching CAN1 bus terminal resistor === 269 269 270 270 271 271 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table: ... ... @@ -274,7 +274,7 @@ 274 274 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected 275 275 |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected 276 276 277 -=== J3 – jumper for switching CAN2 bus terminal resistor === 276 +=== 2.2.17 J3 – jumper for switching CAN2 bus terminal resistor === 278 278 279 279 280 280 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H** and **CAN2_L** lines, install a jumper. The jumper is installed according to the table: ... ... @@ -283,49 +283,49 @@ 283 283 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN2 bus is connected 284 284 |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN2 bus is disconnected 285 285 286 -=== J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 285 +=== 2.2.18 J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 287 287 288 288 The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 289 289 290 -== Indicators == 289 +== 2.3 Indicators == 291 291 292 -=== DS1 – LED indicating device power === 291 +=== 2.3.1 DS1 – LED indicating device power === 293 293 294 294 |**State**|**Description** 295 295 |**Lights up green**|Device power (+5V) is present 296 296 |**Doesn’t light up**|No device power 297 297 298 -=== DS2 – LED indicating device work === 297 +=== 2.3.2 DS2 – LED indicating device work === 299 299 300 300 |**State**|**Description** 301 301 |**Blinking green**|Executing the battery management program 302 302 |**No blinking**|Program execution error 303 303 304 -=== DS3 – LED indicating interaction with BMS Logic === 303 +=== 2.3.3 DS3 – LED indicating interaction with BMS Logic === 305 305 306 306 |**State**|**Description** 307 307 |**Blinking yellow**|The device interacts with BMS Logic devices 308 308 |**No blinking**|- 309 309 310 -=== DS4 – LED indicating loss of connection with BMS Logic === 309 +=== 2.3.4 DS4 – LED indicating loss of connection with BMS Logic === 311 311 312 312 |**State**|**Description** 313 313 |**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost 314 314 |**No blinking**|Communication with BMS Logic is stable 315 315 316 -=== DS5-DS10 – LEDs indicating contactor switches 1-6 === 315 +=== 2.3.5 DS5-DS10 – LEDs indicating contactor switches 1-6 === 317 317 318 318 |**State**|**Description** 319 319 |**Lights up green**|The switch supplies voltage to the contactor winding 320 320 |**Doesn’t light up**|The switch doesn’t supply voltage to the contactor winding 321 321 322 -=== DS11 – LED indicating the presence of power supply for contactors === 321 +=== 2.3.6 DS11 – LED indicating the presence of power supply for contactors === 323 323 324 324 |**State**|**Description** 325 325 |**Lights up green**|Power supply for contactor switches (9-32V) is present 326 326 |**Doesn’t light up**|Power supply for contactor switches (9-32V) is not present 327 327 328 -== Connection procedure == 327 +== 2.4 Connection procedure == 329 329 330 330 (% class="box warningmessage" %) 331 331 (((