Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,6 @@ 1 -(% data-numbered-headings-start="1" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0)" %) 2 -= = 1 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Installation and connection = 3 + 3 3 == Installation procedure == 4 4 5 5 The mounting location of the BMS Main 3.0 device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. ... ... @@ -13,7 +13,7 @@ 13 13 |Mounting dimensions (length × width), mm|194 × 114 14 14 |Mounting holes|M3 15 15 16 -== 2.2Headers ==17 +== Headers == 17 17 18 18 The location and designation of connectors on the BMS Main 3.0 device are shown below. 19 19 ... ... @@ -28,7 +28,7 @@ 28 28 All headers are shown from the device side! 29 29 ))) 30 30 31 -=== 2.2.1X1 – header to power the device ===32 +=== X1 – header to power the device === 32 32 33 33 (% class="wikigeneratedid" id="H" %) 34 34 (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] ... ... @@ -43,7 +43,7 @@ 43 43 44 44 (% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]] 45 45 46 -=== (% title="Click and drag to resize" %)(%%)2.2.2X2 – header for contactors ===47 +=== X2 – header for contactors === 47 47 48 48 (% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 49 49 ... ... @@ -60,7 +60,7 @@ 60 60 61 61 (% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]] 62 62 63 -=== (% title="Click and drag to resize" %)(%%) 2.2.3X3 – header for discrete inputs and outputs ===64 +=== (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 64 64 65 65 (% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 66 66 ... ... @@ -87,9 +87,9 @@ 87 87 88 88 (% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 89 89 90 - (% aria-label="1732121942791-517.png image widget" data-widget="image" contenteditable="false"role="region" tabindex="-1" %)[[image:1732121942791-517.png||data-xwiki-image-style-alignment="center" height="90" width="269"]](% title="Click and drag to resize" %)(% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)2.2.4X4 – header for HVIL91 +=== X4 – header for HVIL === 91 91 92 - (% aria-label="1732122015188-642.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]](% title="Click and drag to resize" %)93 +[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 93 93 94 94 |**Pin**|**Name**|**Description** 95 95 |**1**|**-**|Not used ... ... @@ -101,9 +101,9 @@ 101 101 102 102 Connection diagram to the current loop: 103 103 104 - (% aria-label="1732122067418-263.png image widget" data-widget="image" contenteditable="false"role="region" tabindex="-1" %)[[image:1732122067418-263.png||data-xwiki-image-style-alignment="center" height="264" width="356"]](% title="Click and drag to resize" %)(% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)2.2.5X5 – header for current and temperature sensors105 +=== X5 – header for current and temperature sensors === 105 105 106 - (% aria-label="image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]](% title="Click and drag to resize" %)107 +[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 107 107 108 108 (% style="width:539px" %) 109 109 |**Pin**|**Name**|(% style="width:402px" %)**Description** ... ... @@ -132,7 +132,7 @@ 132 132 133 133 [[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]] 134 134 135 -=== 2.2.6X6 – header for CAN1 and RS-485-1 (external buses) ===136 +=== X6 – header for CAN1 and RS-485-1 (external buses) === 136 136 137 137 [[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 138 138 ... ... @@ -151,7 +151,7 @@ 151 151 152 152 [[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]] 153 153 154 -=== 2.2.7X7 – header for CAN2 (internal bus) ===155 +=== X7 – header for CAN2 (internal bus) === 155 155 156 156 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 157 157 ... ... @@ -165,7 +165,7 @@ 165 165 166 166 [[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]] 167 167 168 -=== 2.2.8X8 – header for CAN3 ===169 +=== X8 – header for CAN3 === 169 169 170 170 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 171 171 ... ... @@ -184,7 +184,7 @@ 184 184 185 185 [[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" height="153" width="417"]] 186 186 187 -=== 2.2.9X9 – header for BMS Logic (RS-485-2) ===188 +=== X9 – header for BMS Logic (RS-485-2) === 188 188 189 189 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 190 190 ... ... @@ -198,11 +198,11 @@ 198 198 199 199 [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" height="163" width="400"]] 200 200 201 -=== 2.2.10X10 – miniUSB connector ===202 +=== X10 – miniUSB connector === 202 202 203 203 The miniUSB connector is used to configure the parameters of the BMS Main 3.0 device. 204 204 205 -=== 2.2.11X11 – header for high-voltage bus before contactors (plus) ===206 +=== X11 – header for high-voltage bus before contactors (plus) === 206 206 207 207 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 208 208 ... ... @@ -215,7 +215,7 @@ 215 215 The connected voltage must not exceed 1000V. 216 216 ))) 217 217 218 -=== 2.2.12X12 – header for high-voltage bus before contactors (minus) ===219 +=== X12 – header for high-voltage bus before contactors (minus) === 219 219 220 220 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 221 221 ... ... @@ -228,7 +228,7 @@ 228 228 The connected voltage must not exceed 1000V. 229 229 ))) 230 230 231 -=== 2.2.13X13 – header for high-voltage bus after contactors (plus) ===232 +=== X13 – header for high-voltage bus after contactors (plus) === 232 232 233 233 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 234 234 ... ... @@ -241,7 +241,7 @@ 241 241 The connected voltage must not exceed 1000V. 242 242 ))) 243 243 244 -=== 2.2.14X14 – header for high-voltage bus after contactors (minus) ===245 +=== X14 – header for high-voltage bus after contactors (minus) === 245 245 246 246 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 247 247 ... ... @@ -254,7 +254,7 @@ 254 254 The connected voltage must not exceed 1000V. 255 255 ))) 256 256 257 -=== 2.2.15J1 – jumper for switching RS-485-1 bus terminal resistor ===258 +=== J1 – jumper for switching RS-485-1 bus terminal resistor === 258 258 259 259 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 260 260 ... ... @@ -264,7 +264,7 @@ 264 264 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected 265 265 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected 266 266 267 -=== 2.2.16J2 – jumper for switching CAN1 bus terminal resistor ===268 +=== J2 – jumper for switching CAN1 bus terminal resistor === 268 268 269 269 270 270 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table: ... ... @@ -273,7 +273,7 @@ 273 273 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected 274 274 |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected 275 275 276 -=== 2.2.17J3 – jumper for switching CAN2 bus terminal resistor ===277 +=== J3 – jumper for switching CAN2 bus terminal resistor === 277 277 278 278 279 279 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H** and **CAN2_L** lines, install a jumper. The jumper is installed according to the table: ... ... @@ -282,49 +282,49 @@ 282 282 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN2 bus is connected 283 283 |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN2 bus is disconnected 284 284 285 -=== 2.2.18J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===286 +=== J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 286 286 287 287 The BMS Main 3 device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 288 288 289 -== 2.3Indicators ==290 +== Indicators == 290 290 291 -=== 2.3.1DS1 – LED indicating device power ===292 +=== DS1 – LED indicating device power === 292 292 293 293 |**State**|**Description** 294 294 |**Lights up green**|Device power (+5V) is present 295 295 |**Doesn’t light up**|No device power 296 296 297 -=== 2.3.2DS2 – LED indicating device work ===298 +=== DS2 – LED indicating device work === 298 298 299 299 |**State**|**Description** 300 300 |**Blinking green**|Executing the battery management program 301 301 |**No blinking**|Program execution error 302 302 303 -=== 2.3.3DS3 – LED indicating interaction with BMS Logic ===304 +=== DS3 – LED indicating interaction with BMS Logic === 304 304 305 305 |**State**|**Description** 306 306 |**Blinking yellow**|The device interacts with BMS Logic devices 307 307 |**No blinking**|- 308 308 309 -=== 2.3.4DS4 – LED indicating loss of connection with BMS Logic ===310 +=== DS4 – LED indicating loss of connection with BMS Logic === 310 310 311 311 |**State**|**Description** 312 312 |**Blinking/lights up red**|Communication with one or more BMS Logic devices is lost 313 313 |**No blinking**|Communication with BMS Logic is stable 314 314 315 -=== 2.3.5DS5-DS10 – LEDs indicating contactor switches 1-6 ===316 +=== DS5-DS10 – LEDs indicating contactor switches 1-6 === 316 316 317 317 |**State**|**Description** 318 318 |**Lights up green**|The switch supplies voltage to the contactor winding 319 319 |**Doesn’t light up**|The switch doesn’t supply voltage to the contactor winding 320 320 321 -=== 2.3.6DS11 – LED indicating the presence of power supply for contactors ===322 +=== DS11 – LED indicating the presence of power supply for contactors === 322 322 323 323 |**State**|**Description** 324 324 |**Lights up green**|Power supply for contactor switches (9-32V) is present 325 325 |**Doesn’t light up**|Power supply for contactor switches (9-32V) is not present 326 326 327 -== 2.4Connection procedure ==328 +== Connection procedure == 328 328 329 329 (% class="box warningmessage" %) 330 330 (((