Wiki source code of 1. Overview

Version 1.4 by Admin on 2024/11/20 15:45

Hide last authors
Admin 1.4 1 = 1.1 Basic functions =
Admin 1.3 2
Admin 1.2 3 [[Figure 1. BMS Main 3.0>>image:1732117351688-532.png||data-xwiki-image-style-alignment="center" height="202" width="474"]]
4
Admin 1.3 5
Admin 1.2 6 The BMS Main 3.0 device is a modular battery management system (BMS) controller and performs the following functions:
7
8 * collection of information about the voltage and temperature of battery cells from BMS Logic devices;
9 * measurement of current through the battery;
10 * battery protection by opening the charge and discharge circuits in case of overcharge, deep discharge, short circuit, overheating, overcooling of the battery and under other conditions;
11 * determination of the battery state (state of charge, state of health, effective capacity, internal cell resistance, etc.);
12 * battery cell balancing control;
13 * communication with other devices (charging station, display panels, vehicle controller, etc.).
14
15
16 The BMS Main 3.0 device is flexibly configured and can work with various types of lithium-ion batteries: LFP (LiFePO4 and LiFeYPO4), LCO (LiCoO2), LMO (LiMn2O4), NMC (LiNiMnCoO2), NCA (LiNiCoAlO2), LTO (Li4Ti5O12), etc.
17
Admin 1.4 18 = 1.2 Specifications =
Admin 1.2 19
20 |**Parameter**|**Value**
21 |(% colspan="2" %)**Power supply**
22 |Supply voltage, V|9 to 32
23 |Current consumption at supply voltage 24 V, mA, max|150
24 |KEYRUN or CHARGE_ON signal for turning on the device, V, min|8.5
25 |(% colspan="2" %)**Scalability**
26 |Number of connected BMS Logic devices, max|40
27 |Number of controlled cells, max|720
28 |(((
29 **Number of battery modules connected in parallel, max**
30
31 //If the device is used as a parallel battery module controller, it is necessary to install modified firmware that changes the device type to BMS Main 3X//
32 )))|
33 |(% colspan="2" %)**Controls**
34 |Number of programmable switches for controlling contactors (9-32V, 2.5A)|6
35 |Number of programmable discrete inputs (dry contact)|6
36 |Number of programmable discrete inputs 9-32V|2
37 |Number of programmable discrete outputs (open drain, 40V, 1A)|4
38 |(% colspan="2" %)**Sensors**
39 |Number of connected current sensors (two signal lines for each sensor)|3
40 |(((
41 Error in measuring signals from current sensors, V, max
42
43 //At ambient temperature 25 ± 5 ºС//
44 )))|0.001
45 |Current sensor types|(((
46 Bidirectional with 5V supply voltage
47
48 (LEM series HASS, HTFS, DHAB or analogues)
49 )))
50 |Number of high voltage measurement inputs (two signal lines for each input)|2
51 |High voltage measurement range, V|10 to 1000
52 |High voltage measurement error, V, max|± 2
53 |Number of connected external temperature sensors (100 kOhm NTC-thermistors)|2
54 |(((
55 Temperature measurement error using external temperature sensors, ºС, max
56
57 //In the measurement range from -20 to +85 ºС//
58 )))|± 2
59 |Temperature measurement error using a built-in temperature sensor, ºС, max|± 2
60 |Humidity measurement error using a built-in humidity sensor, %, max|± 10
61 |(% colspan="2" %)**High-voltage interlock loop (HVIL)**
62 |Current in the HVIL, mA, typical|25
63 |Total resistance in the HVIL, Ohm, max|200
64 |(% colspan="2" %)**Interfaces**
65 |Number of USB interfaces|1
66 |USB speed, Mbit/s|12
67 |Number of CAN interfaces|3
68 |CAN speed, kbit/s|125, 250 (by default), 500, 1000
69 |Number of RS-485 interfaces|2
70 |RS-485 speed, bit/s|600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
71 |Output voltage of CAN2 power supply, V|5.0 ± 0.5
72 |Output current of CAN2 power supply, mA, max|400
73 |Connecting an additional expansion interface module|BMS Wi-Fi, BMS GSM, BMS LANmodule
74 |(% colspan="2" %)**Galvanic isolation**
75 |(((
76 **Rated insulation voltage, V,,RMS,,, min**
77
78 //Conditions: duration 1 minute, AC 50 Hz, 1) between connectors of CAN1, RS-485-1, discrete inputs/outputs interfaces and device power circuits, 2) between connectors of CAN1, RS-485-1, discrete inputs/outputs interfaces and high voltage measurement circuits, 3) between the device power supply circuits and the high voltage measurement circuits//
79 )))|3500
80 |(% colspan="2" %)**Weight and overall dimensions**
81 |Overall dimensions (length × weight × height), mm|200 × 123 × 12
82 |Weight, g, max|160 ± 5
83 |(% colspan="2" %)**Operating conditions**
84 |Operating temperature range, °С|-40 to +85
85
86
87 1.
88 11. Description of features
89
90 The BMS Main 3.0 device is powered from an external source having an output voltage in the range from 9 to 32V (connector X1). The device is turned on when there is power and the KEYRUN or CHARGE_ON signal is supplied with a level of at least 8.5V.
91
92
93 Up to 40 measuring devices BMS Logic 12, BMS Logic 18, BMS Logic RET (X9 connector) can be connected to BMS Main 3.0, while the maximum battery voltage can reach 3000V (assuming that 720 cells are connected with a maximum voltage of 4.2V).
94
95
96 The BMS Main 3.0 device can control 6 contactors (connector X2). For control, intelligent keys are used that monitor the switching current and their own temperature, generating a high-level voltage to power the contactor windings.
97
98
99 To control battery operating modes, BMS Main 3.0 provides 8 discrete inputs (connector X3), two of which detect voltage in the range from 9 to 32V, the other six are connected to outputs of the “dry contact”, “open collector” or “open drain” type and detecting a short circuit of the signal input to the virtual ground of the device.
100
101
102 The BMS Main 3.0 device has additional 4 open-drain discrete outputs (connector X3) for issuing control commands to an external circuit.
103
104
105 Up to 3 current sensors with unipolar +5V power supply and two signal lines (connector X5) can be connected to BMS Main 3.0. The device is compatible with LEM sensors of the HASS, HTFS, DHAB series or similar from other manufacturers. Using two or three current sensors, a complex battery system can be implemented (for example, an inverter power system with a midpoint and monitoring the current in each of the two battery segments).
106
107
108 The device has 2 channels for measuring high (up to 1000V) voltage (connectors X11-X14). Using these channels to measure the voltage on the power bus before the contactors and after the contactors, the device controls the process of precharging the capacitors in the load and determines the welding (sticking) of the contacts of the power contactors.
109
110
111 2 external thermistors (connectors X5) can be connected to BMS Main 3.0 to measure the temperature in the battery container and/or the temperature of the power contactor. The device software allows to configure the protective opening of the contactor when it overheats.
112
113
114 The device continuously monitors its own temperature and humidity of the surrounding air using built-in sensors. The BMS Main 3.0 software allows you to configure the protective opening of all contactors at critically high ambient humidity.
115
116
117 The device implements a circuit for active monitoring of the integrity of a high-voltage bus (high voltage interlock loop, HVIL). BMS Main 3.0 outputs a modulated signal into the current loop and controls the current value in it (connector X4). If there is a discrepancy between the measured and required current values, the device opens the power contactors.
118
119
120 The BMS Main 3.0 device has the following interfaces:
121
122 * USB – used to configure device parameters using the ElectricDeviceMonitor software;
123 * CAN1 – used for communication with external equipment (charging station, vehicle controller, etc.);
124 * CAN2 – used to configure device parameters using the ElectricDeviceMonitor software and for communication with indication devices BMS Indication, BMS Display;
125 * CAN3 – used for communication with other battery controllers (in battery systems consisting of several batteries connected in parallel), as well as with next generation BMS Logic devices;
126 * RS-485-1 – used for communication with external equipment via the Modbus RTU protocol;
127 * RS-485-2 - used for communication with current generation BMS Logic devices.
128
129 On the device board there is a P2 connector for connecting an expansion communication module: BMS Wi-Fi, BMS GSM or BMS LANmodule. With these modules, user can configure device parameters using the ElectricDeviceMonitor software and transfer accumulated log files with the state of the battery system to a remote server.
130
131
132 The device can be used as a controller of several battery modules connected in parallel and controlled by other BMS Main 3 devices. To do this, install modified firmware that changes the device type to BMS Main 3X.