Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/12 10:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -40,7 +40,7 @@ 40 40 Error in measuring signals from current sensors, V, max 41 41 42 42 //At ambient temperature 25 ± 5 ºС// 43 -)))|(% style="width:162px" %) ±0.00143 +)))|(% style="width:162px" %)0.001 44 44 |(% style="width:490px" %)Current sensor types|(% style="width:162px" %)((( 45 45 Bidirectional with 5V supply voltage 46 46 ... ... @@ -80,7 +80,7 @@ 80 80 )))|(% style="width:162px" %)3500 81 81 |(% colspan="2" style="width:654px" %)**Weight and overall dimensions** 82 82 |(% style="width:490px" %)Overall dimensions (length × weight × height), mm|(% style="width:162px" %)200 × 123 × 12 83 -|(% style="width:490px" %)Weight, g, max|(% style="width:162px" %)1 50 ±1083 +|(% style="width:490px" %)Weight, g, max|(% style="width:162px" %)160 ± 5 84 84 |(% colspan="2" style="width:654px" %)**Operating conditions** 85 85 |(% style="width:490px" %)Operating temperature range, °С|(% style="width:162px" %)-40 to +85 86 86