Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/12 10:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,8 @@ 1 1 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Technical specifications = 3 3 4 -[[image:1732117351688-532.png||data-xwiki-image-style-alignment="center" height="2 02" width="474"]]5 -The BMS Main 3 .0device is a modular battery management system (BMS) controller and performs the following functions:4 +[[image:1732117351688-532.png||data-xwiki-image-style-alignment="center" height="256" width="600"]] 5 +The BMS Main 3 device is a modular battery management system (BMS) controller and performs the following functions: 6 6 7 7 * collection of information about the voltage and temperature of battery cells from BMS Logic devices; 8 8 * measurement of current through the battery; ... ... @@ -11,19 +11,24 @@ 11 11 * battery cell balancing control; 12 12 * communication with other devices (charging station, display panels, vehicle controller, etc.). 13 13 14 -The BMS Main 3 .0device is flexibly configured and can work with various types of lithium-ion batteries: LFP (LiFePO4 and LiFeYPO4), LCO (LiCoO2), LMO (LiMn2O4), NMC (LiNiMnCoO2), NCA (LiNiCoAlO2), LTO (Li4Ti5O12), etc.14 +The BMS Main 3 device is flexibly configured and can work with various types of lithium-ion batteries: LFP (LiFePO4 and LiFeYPO4), LCO (LiCoO2), LMO (LiMn2O4), NMC (LiNiMnCoO2), NCA (LiNiCoAlO2), LTO (Li4Ti5O12), etc. 15 15 16 +(% class="box infomessage" %) 17 +((( 18 +**Note:** BMS Main 3 and BMS Main 3X are different products based on the same PCB while using different firmware. You can easily switch from BMS Main 3 to BMS Main 3X by flashing the corresponding [[firmware>>doc:Firmware.bms-main-3x.WebHome]]. 19 +))) 20 + 16 16 == Specifications == 17 17 18 18 (% style="width:657px" %) 19 19 |(% style="width:490px" %)**Parameter**|(% style="width:162px" %)**Value** 20 -|(% colspan="2" style="width:654px" %)**Power supply** 25 +|(% colspan="2" style="vertical-align:middle; width:654px" %)**Power supply** 21 21 |(% style="width:490px" %)Supply voltage, V|(% style="width:162px" %)9 to 32 22 22 |(% style="width:490px" %)Current consumption at supply voltage 24 V, mA, max|(% style="width:162px" %)150 23 23 |(% style="width:490px" %)KEYRUN or CHARGE_ON signal for turning on the device, V, min|(% style="width:162px" %)8.5 24 24 |(% colspan="2" style="width:654px" %)**Scalability** 25 -|(% style="width:490px" %)Number of connected BMS Logic devices, max|(% style="width:162px" %)40 26 -|(% style="width:490px" %)Number of controlled cells, max|(% style="width:162px" %)720 30 +|(% style="width:490px" %)**Number of connected BMS Logic devices, max**|(% style="width:162px" %)40 31 +|(% style="width:490px" %)**Number of controlled cells, max**|(% style="width:162px" %)720 27 27 |(% colspan="2" style="width:654px" %)**Controls** 28 28 |(% style="width:490px" %)Number of programmable switches for controlling contactors (9-32V, 2.5A)|(% style="width:162px" %)6 29 29 |(% style="width:490px" %)Number of programmable discrete inputs (dry contact)|(% style="width:162px" %)6 ... ... @@ -80,7 +80,7 @@ 80 80 == Overall and mounting dimensions == 81 81 82 82 83 -[[image:1733310978839-565.png||data-xwiki-image-style-alignment="center" height=" 486" width="810"]] [[image:1733310978846-154.png||data-xwiki-image-style-alignment="center" height="172" width="767"]]88 +[[image:1733310978839-565.png||data-xwiki-image-style-alignment="center" height="360" width="600"]] [[image:1733310978846-154.png||data-xwiki-image-style-alignment="center" height="134" width="600"]] 84 84 85 85 == Description of features == 86 86
- 1735234124855-178.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +567.0 KB - Content