Last modified by Admin on 2025/05/12 10:19

From version 12.1
edited by Admin
on 2024/12/11 11:53
Change comment: There is no comment for this version
To version 15.1
edited by Admin
on 2024/12/12 16:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,7 @@
1 1  (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Technical specifications =
3 3  
4 -[[image:1732117351688-532.png||data-xwiki-image-style-alignment="center" height="202" width="474"]]
4 +[[image:1732117351688-532.png||data-xwiki-image-style-alignment="center" height="256" width="600"]]
5 5  The BMS Main 3.0 device is a modular battery management system (BMS) controller and performs the following functions:
6 6  
7 7  * collection of information about the voltage and temperature of battery cells from BMS Logic devices;
... ... @@ -13,6 +13,11 @@
13 13  
14 14  The BMS Main 3.0 device is flexibly configured and can work with various types of lithium-ion batteries: LFP (LiFePO4 and LiFeYPO4), LCO (LiCoO2), LMO (LiMn2O4), NMC (LiNiMnCoO2), NCA (LiNiCoAlO2), LTO (Li4Ti5O12), etc.
15 15  
16 +(% class="box infomessage" %)
17 +(((
18 +**Note:** BMS Main 3 and BMS Main 3X are different products based on the same PCB while using different firmware. You can easily switch from one device to another by flashing the corresponding [[firmware>>doc:Firmware.WebHome]].
19 +)))
20 +
16 16  == Specifications ==
17 17  
18 18  (% style="width:657px" %)
... ... @@ -24,11 +24,6 @@
24 24  |(% colspan="2" style="width:654px" %)**Scalability**
25 25  |(% style="width:490px" %)Number of connected BMS Logic devices, max|(% style="width:162px" %)40
26 26  |(% style="width:490px" %)Number of controlled cells, max|(% style="width:162px" %)720
27 -|(% style="width:490px" %)(((
28 -**Number of battery modules connected in parallel, max**
29 -
30 -//If the device is used as a parallel battery module controller, it is necessary to install modified firmware that changes the device type to BMS Main 3X//
31 -)))|(% style="width:162px" %)32
32 32  |(% colspan="2" style="width:654px" %)**Controls**
33 33  |(% style="width:490px" %)Number of programmable switches for controlling contactors (9-32V, 2.5A)|(% style="width:162px" %)6
34 34  |(% style="width:490px" %)Number of programmable discrete inputs (dry contact)|(% style="width:162px" %)6