... ... @@ -13,6 +13,11 @@
13 13  
14 14  The BMS Main 3.0 device is flexibly configured and can work with various types of lithium-ion batteries: LFP (LiFePO4 and LiFeYPO4), LCO (LiCoO2), LMO (LiMn2O4), NMC (LiNiMnCoO2), NCA (LiNiCoAlO2), LTO (Li4Ti5O12), etc.
15 15  
16 +(% class="box infomessage" %)
17 +(((
18 +**Note:** BMS Main 3 and BMS Main 3X are different products that share the same PCB, but use different firmware. You can easily switch from one device to another by flashing the corresponding [[firmware>>doc:Firmware.WebHome]].
19 +)))
20 +
16 16  == Specifications ==
17 17  
18 18  (% style="width:657px" %)
... ... @@ -24,11 +24,6 @@
24 24  |(% colspan="2" style="width:654px" %)**Scalability**
25 25  |(% style="width:490px" %)Number of connected BMS Logic devices, max|(% style="width:162px" %)40
26 26  |(% style="width:490px" %)Number of controlled cells, max|(% style="width:162px" %)720
27 -|(% style="width:490px" %)(((
28 -**Number of battery modules connected in parallel, max**
29 -
30 -//If the device is used as a parallel battery module controller, it is necessary to install modified firmware that changes the device type to BMS Main 3X//
31 -)))|(% style="width:162px" %)32
32 32  |(% colspan="2" style="width:654px" %)**Controls**
33 33  |(% style="width:490px" %)Number of programmable switches for controlling contactors (9-32V, 2.5A)|(% style="width:162px" %)6
34 34  |(% style="width:490px" %)Number of programmable discrete inputs (dry contact)|(% style="width:162px" %)6