106 106  The device implements a circuit for active monitoring of the integrity of a high-voltage bus (high voltage interlock loop, HVIL). BMS Main 3.0 outputs a modulated signal into the current loop and controls the current value in it (connector X4). If there is a discrepancy between the measured and required current values, the device opens the power contactors.
107 107  
108 +
108 108  The BMS Main 3.0 device has the following interfaces:
109 109  
110 110  * USB – used to configure device parameters using the ElectricDeviceMonitor software;