Last modified by Admin on 2025/05/12 10:19

From version 1.2
edited by Admin
on 2024/11/20 15:43
Change comment: There is no comment for this version
To version 4.1
edited by Admin
on 2024/12/04 11:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Overview
1 +1. Technical specifications
Content
... ... @@ -1,5 +1,6 @@
1 -[[Figure 1. BMS Main 3.0>>image:1732117351688-532.png||data-xwiki-image-style-alignment="center" height="202" width="474"]]
1 +[[image:1732117351688-532.png||data-xwiki-image-style-alignment="center" height="202" width="474"]]
2 2  
3 +
3 3  The BMS Main 3.0 device is a modular battery management system (BMS) controller and performs the following functions:
4 4  
5 5  * collection of information about the voltage and temperature of battery cells from BMS Logic devices;
... ... @@ -9,112 +9,104 @@
9 9  * battery cell balancing control;
10 10  * communication with other devices (charging station, display panels, vehicle controller, etc.).
11 11  
12 -
13 13  The BMS Main 3.0 device is flexibly configured and can work with various types of lithium-ion batteries: LFP (LiFePO4 and LiFeYPO4), LCO (LiCoO2), LMO (LiMn2O4), NMC (LiNiMnCoO2), NCA (LiNiCoAlO2), LTO (Li4Ti5O12), etc.
14 14  
15 -1.
16 -11. Specifications
15 +== 1.1 Specifications ==
17 17  
18 -|**Parameter**|**Value**
19 -|(% colspan="2" %)**Power supply**
20 -|Supply voltage, V|9 to 32
21 -|Current consumption at supply voltage 24 V, mA, max|150
22 -|KEYRUN or CHARGE_ON signal for turning on the device, V, min|8.5
23 -|(% colspan="2" %)**Scalability**
24 -|Number of connected BMS Logic devices, max|40
25 -|Number of controlled cells, max|720
26 -|(((
17 +(% style="width:657px" %)
18 +|(% style="width:490px" %)**Parameter**|(% style="width:162px" %)**Value**
19 +|(% colspan="2" style="width:654px" %)**Power supply**
20 +|(% style="width:490px" %)Supply voltage, V|(% style="width:162px" %)9 to 32
21 +|(% style="width:490px" %)Current consumption at supply voltage 24 V, mA, max|(% style="width:162px" %)150
22 +|(% style="width:490px" %)KEYRUN or CHARGE_ON signal for turning on the device, V, min|(% style="width:162px" %)8.5
23 +|(% colspan="2" style="width:654px" %)**Scalability**
24 +|(% style="width:490px" %)Number of connected BMS Logic devices, max|(% style="width:162px" %)40
25 +|(% style="width:490px" %)Number of controlled cells, max|(% style="width:162px" %)720
26 +|(% style="width:490px" %)(((
27 27  **Number of battery modules connected in parallel, max**
28 28  
29 29  //If the device is used as a parallel battery module controller, it is necessary to install modified firmware that changes the device type to BMS Main 3X//
30 -)))|
31 -|(% colspan="2" %)**Controls**
32 -|Number of programmable switches for controlling contactors (9-32V, 2.5A)|6
33 -|Number of programmable discrete inputs (dry contact)|6
34 -|Number of programmable discrete inputs 9-32V|2
35 -|Number of programmable discrete outputs (open drain, 40V, 1A)|4
36 -|(% colspan="2" %)**Sensors**
37 -|Number of connected current sensors (two signal lines for each sensor)|3
38 -|(((
30 +)))|(% style="width:162px" %)32
31 +|(% colspan="2" style="width:654px" %)**Controls**
32 +|(% style="width:490px" %)Number of programmable switches for controlling contactors (9-32V, 2.5A)|(% style="width:162px" %)6
33 +|(% style="width:490px" %)Number of programmable discrete inputs (dry contact)|(% style="width:162px" %)6
34 +|(% style="width:490px" %)Number of programmable discrete inputs 9-32V|(% style="width:162px" %)2
35 +|(% style="width:490px" %)Number of programmable discrete outputs (open drain, 40V, 1A)|(% style="width:162px" %)4
36 +|(% colspan="2" style="width:654px" %)**Sensors**
37 +|(% style="width:490px" %)Number of connected current sensors (two signal lines for each sensor)|(% style="width:162px" %)3
38 +|(% style="width:490px" %)(((
39 39  Error in measuring signals from current sensors, V, max
40 40  
41 41  //At ambient temperature 25 ± 5 ºС//
42 -)))|0.001
43 -|Current sensor types|(((
42 +)))|(% style="width:162px" %)0.001
43 +|(% style="width:490px" %)Current sensor types|(% style="width:162px" %)(((
44 44  Bidirectional with 5V supply voltage
45 45  
46 46  (LEM series HASS, HTFS, DHAB or analogues)
47 47  )))
48 -|Number of high voltage measurement inputs (two signal lines for each input)|2
49 -|High voltage measurement range, V|10 to 1000
50 -|High voltage measurement error, V, max|± 2
51 -|Number of connected external temperature sensors (100 kOhm NTC-thermistors)|2
52 -|(((
48 +|(% style="width:490px" %)Number of high voltage measurement inputs (two signal lines for each input)|(% style="width:162px" %)2
49 +|(% style="width:490px" %)High voltage measurement range, V|(% style="width:162px" %)10 to 1000
50 +|(% style="width:490px" %)High voltage measurement error, V, max|(% style="width:162px" %)± 2
51 +|(% style="width:490px" %)Number of connected external temperature sensors (100 kOhm NTC-thermistors)|(% style="width:162px" %)2
52 +|(% style="width:490px" %)(((
53 53  Temperature measurement error using external temperature sensors, ºС, max
54 54  
55 55  //In the measurement range from -20 to +85 ºС//
56 -)))|± 2
57 -|Temperature measurement error using a built-in temperature sensor, ºС, max|± 2
58 -|Humidity measurement error using a built-in humidity sensor, %, max|± 10
59 -|(% colspan="2" %)**High-voltage interlock loop (HVIL)**
60 -|Current in the HVIL, mA, typical|25
61 -|Total resistance in the HVIL, Ohm, max|200
62 -|(% colspan="2" %)**Interfaces**
63 -|Number of USB interfaces|1
64 -|USB speed, Mbit/s|12
65 -|Number of CAN interfaces|3
66 -|CAN speed, kbit/s|125, 250 (by default), 500, 1000
67 -|Number of RS-485 interfaces|2
68 -|RS-485 speed, bit/s|600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
69 -|Output voltage of CAN2 power supply, V|5.0 ± 0.5
70 -|Output current of CAN2 power supply, mA, max|400
71 -|Connecting an additional expansion interface module|BMS Wi-Fi, BMS GSM, BMS LANmodule
72 -|(% colspan="2" %)**Galvanic isolation**
73 -|(((
56 +)))|(% style="width:162px" %)± 2
57 +|(% style="width:490px" %)Temperature measurement error using a built-in temperature sensor, ºС, max|(% style="width:162px" %)± 2
58 +|(% style="width:490px" %)Humidity measurement error using a built-in humidity sensor, %, max|(% style="width:162px" %)± 10
59 +|(% colspan="2" style="width:654px" %)**High-voltage interlock loop (HVIL)**
60 +|(% style="width:490px" %)Current in the HVIL, mA, typical|(% style="width:162px" %)25
61 +|(% style="width:490px" %)Total resistance in the HVIL, Ohm, max|(% style="width:162px" %)200
62 +|(% colspan="2" style="width:654px" %)**Interfaces**
63 +|(% style="width:490px" %)Number of USB interfaces|(% style="width:162px" %)1
64 +|(% style="width:490px" %)USB speed, Mbit/s|(% style="width:162px" %)12
65 +|(% style="width:490px" %)Number of CAN interfaces|(% style="width:162px" %)3
66 +|(% style="width:490px" %)CAN speed, kbit/s|(% style="width:162px" %)125, 250 (by default), 500, 1000
67 +|(% style="width:490px" %)Number of RS-485 interfaces|(% style="width:162px" %)2
68 +|(% style="width:490px" %)RS-485 speed, bit/s|(% style="width:162px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
69 +|(% style="width:490px" %)Output voltage of CAN2 power supply, V|(% style="width:162px" %)5.0 ± 0.5
70 +|(% style="width:490px" %)Output current of CAN2 power supply, mA, max|(% style="width:162px" %)400
71 +|(% style="width:490px" %)Connecting an additional expansion interface module|(% style="width:162px" %)BMS Wi-Fi, BMS GSM, BMS LANmodule
72 +|(% colspan="2" style="width:654px" %)**Galvanic isolation**
73 +|(% style="width:490px" %)(((
74 74  **Rated insulation voltage, V,,RMS,,, min**
75 75  
76 76  //Conditions: duration 1 minute, AC 50 Hz, 1) between connectors of CAN1, RS-485-1, discrete inputs/outputs interfaces and device power circuits, 2) between connectors of CAN1, RS-485-1, discrete inputs/outputs interfaces and high voltage measurement circuits, 3) between the device power supply circuits and the high voltage measurement circuits//
77 -)))|3500
78 -|(% colspan="2" %)**Weight and overall dimensions**
79 -|Overall dimensions (length × weight × height), mm|200 × 123 × 12
80 -|Weight, g, max|160 ± 5
81 -|(% colspan="2" %)**Operating conditions**
82 -|Operating temperature range, °С|-40 to +85
77 +)))|(% style="width:162px" %)3500
78 +|(% colspan="2" style="width:654px" %)**Weight and overall dimensions**
79 +|(% style="width:490px" %)Overall dimensions (length × weight × height), mm|(% style="width:162px" %)200 × 123 × 12
80 +|(% style="width:490px" %)Weight, g, max|(% style="width:162px" %)160 ± 5
81 +|(% colspan="2" style="width:654px" %)**Operating conditions**
82 +|(% style="width:490px" %)Operating temperature range, °С|(% style="width:162px" %)-40 to +85
83 83  
84 +== 1.2 Overall and mounting dimensions ==
84 84  
85 -1.
86 -11. Description of features
87 87  
88 -The BMS Main 3.0 device is powered from an external source having an output voltage in the range from 9 to 32V (connector X1). The device is turned on when there is power and the KEYRUN or CHARGE_ON signal is supplied with a level of at least 8.5V.
87 +[[image:1733310978839-565.png||data-xwiki-image-style-alignment="center" height="486" width="810"]] [[image:1733310978846-154.png||data-xwiki-image-style-alignment="center" height="172" width="767"]]
89 89  
89 +== 1.3 Description of features ==
90 90  
91 +The BMS Main 3.0 device is powered from an external source having an output voltage in the range from 9 to 32V (connector X1). The device is turned on when there is power and the KEYRUN or CHARGE_ON signal is supplied with a level of at least 8.5V.
92 +
91 91  Up to 40 measuring devices BMS Logic 12, BMS Logic 18, BMS Logic RET (X9 connector) can be connected to BMS Main 3.0, while the maximum battery voltage can reach 3000V (assuming that 720 cells are connected with a maximum voltage of 4.2V).
92 92  
93 -
94 94  The BMS Main 3.0 device can control 6 contactors (connector X2). For control, intelligent keys are used that monitor the switching current and their own temperature, generating a high-level voltage to power the contactor windings.
95 95  
96 -
97 97  To control battery operating modes, BMS Main 3.0 provides 8 discrete inputs (connector X3), two of which detect voltage in the range from 9 to 32V, the other six are connected to outputs of the “dry contact”, “open collector” or “open drain” type and detecting a short circuit of the signal input to the virtual ground of the device.
98 98  
99 -
100 100  The BMS Main 3.0 device has additional 4 open-drain discrete outputs (connector X3) for issuing control commands to an external circuit.
101 101  
102 -
103 103  Up to 3 current sensors with unipolar +5V power supply and two signal lines (connector X5) can be connected to BMS Main 3.0. The device is compatible with LEM sensors of the HASS, HTFS, DHAB series or similar from other manufacturers. Using two or three current sensors, a complex battery system can be implemented (for example, an inverter power system with a midpoint and monitoring the current in each of the two battery segments).
104 104  
105 -
106 106  The device has 2 channels for measuring high (up to 1000V) voltage (connectors X11-X14). Using these channels to measure the voltage on the power bus before the contactors and after the contactors, the device controls the process of precharging the capacitors in the load and determines the welding (sticking) of the contacts of the power contactors.
107 107  
105 +Two external thermistors (connectors X5) can be connected to BMS Main 3.0 to measure the temperature in the battery container and/or the temperature of the power contactor. The device software allows to configure the protective opening of the contactor when it overheats.
108 108  
109 -2 external thermistors (connectors X5) can be connected to BMS Main 3.0 to measure the temperature in the battery container and/or the temperature of the power contactor. The device software allows to configure the protective opening of the contactor when it overheats.
110 -
111 -
112 112  The device continuously monitors its own temperature and humidity of the surrounding air using built-in sensors. The BMS Main 3.0 software allows you to configure the protective opening of all contactors at critically high ambient humidity.
113 113  
114 -
115 115  The device implements a circuit for active monitoring of the integrity of a high-voltage bus (high voltage interlock loop, HVIL). BMS Main 3.0 outputs a modulated signal into the current loop and controls the current value in it (connector X4). If there is a discrepancy between the measured and required current values, the device opens the power contactors.
116 116  
117 -
118 118  The BMS Main 3.0 device has the following interfaces:
119 119  
120 120  * USB – used to configure device parameters using the ElectricDeviceMonitor software;
... ... @@ -126,5 +126,22 @@
126 126  
127 127  On the device board there is a P2 connector for connecting an expansion communication module: BMS Wi-Fi, BMS GSM or BMS LANmodule. With these modules, user can configure device parameters using the ElectricDeviceMonitor software and transfer accumulated log files with the state of the battery system to a remote server.
128 128  
129 -
130 130  The device can be used as a controller of several battery modules connected in parallel and controlled by other BMS Main 3 devices. To do this, install modified firmware that changes the device type to BMS Main 3X.
123 +
124 +== 1.4 Typical battery system diagram ==
125 +
126 +Figure below shows an example of a functional diagram of a vehicle battery.[[image:https://docs.movicomelectric.com/bin/download/drafts/bms-main-3/battery-diagram/WebHome/1732118894784-437.png?width=556&height=786&rev=1.1||alt="1732118894784-437.png" data-xwiki-image-style-alignment="center" height="786" width="556"]]
127 +
128 +
129 +
130 +The following are connected to the BMS Main 3.0 device:
131 +
132 +* external power supply 9-32V – contacts X1.8 (VIN), X1.2 (GND), X1.3 (KEYRUN);
133 +* 4 BMS Logic 12 measuring devices – contacts X9.4 (LOGIC_5V), X9.3 (GND), X9.2 (LOGIC_A), X9.1 (LOGIC_B);
134 +* Hall-effect current sensor, for example, HASS 300-S – contacts X5.1 (CS1_5V), X5.2 (GND), X5.7 (CS1_IN1), X5.8 (CS1_REF_IN2);
135 +* precharge contactor – control contacts X2.5 (CONT1_OUT), X2.1 (GND);
136 +* main contactor (battery minus) – control contacts X2.6 (CONT2_OUT), X2.2 (GND), feedback contacts X3.9 (DIN1_SIGNAL), X3.1 (DIO_GND);
137 +* combined charge-discharge contactor (battery plus) – control contacts X2.7 (CONT3_OUT), X2.8 (GND), feedback contacts X3.10 (DIN2_SIGNAL), X3.2 (DIO_GND);
138 +* high-voltage bus before contactors – contacts X11.1 (IN1+), X12.1 (IN1-);
139 +* high-voltage bus after contactors – contacts X13.1 (IN2+), X14.1 (IN2-);
140 +* vehicle controller – contacts CAN1 bus X6.1 (CAN1_H), X6.2 (CAN1_L), X6.3 (CAN1_RS485_1_GND).
1733310978839-565.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +155.8 KB
Content
1733310978846-154.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.0 KB