Wiki source code of 2. Installation and connection

Version 87.1 by Admin on 2026/03/25 16:39

Hide last authors
Admin 31.1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Installation and connection =
Admin 30.1 3
Admin 57.1 4 == Safety rules ==
5
Admin 61.1 6 To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS.
Admin 57.1 7
Admin 59.1 8 Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
Admin 57.1 9
Admin 62.1 10 (% class="box errormessage" %)
Admin 56.2 11 (((
Admin 57.1 12 The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
Admin 56.2 13 )))
14
15 (% class="box errormessage" %)
16 (((
Admin 62.1 17 The system is not designed to operate with batteries whose total voltage exceeds 3000 V.
Admin 56.2 18 )))
19
Admin 28.1 20 == Installation procedure ==
Admin 27.1 21
Admin 78.2 22 The mounting location of the BMS Main 2R device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
Admin 27.1 23
24 Overall and mounting dimensions are shown in figure below.
25
Admin 81.2 26 [[image:1774349658793-888.0b.STEP.JPG||data-xwiki-image-style-alignment="center" height="522" width="450"]](% title="Click and drag to resize" %)​
Admin 27.1 27
28 |**Parameter**|**Value**
Admin 81.2 29 |Overall dimensions (length × width × height), mm|120 × 120 × 16
30 |Mounting dimensions (length × width), mm|114 × 114
Admin 27.1 31 |Mounting holes|M3
32
Admin 30.1 33 == Headers ==
Admin 27.1 34
Admin 78.2 35 The location and designation of connectors on the BMS Main 2R device are shown below.
Admin 27.1 36
37 (% contenteditable="false" tabindex="-1" %)
38 (((
Admin 81.2 39 [[image:1774455018488-627.png||data-xwiki-image-style-alignment="center"]]
Admin 27.1 40 )))
41
42 (% class="box warningmessage" %)
43 (((
44 **Attention!**
45 All headers are shown from the device side!
46 )))
47
Admin 81.2 48 === X1 – header for discrete inputs and outputs ===
Admin 27.1 49
Admin 55.3 50 Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF
51
Admin 27.1 52 (% class="wikigeneratedid" id="H" %)
Admin 81.2 53 [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]]
Admin 27.1 54
55 |**Pin**|**Name**|**Description**
Admin 81.2 56 |**1–8**|**GND**|Ground
Admin 81.4 57 |**9**|**DO_1**|Discrete output 1 (+5V, 20mA)
58 |**10**|**DO_2**|Discrete output 2 (+5V, 20mA)
59 |**11**|**DO_3**|Discrete output 3 (+5V, 20mA)
60 |**12**|**DO_4**|Discrete output 4 (+5V, 20mA)
Admin 81.5 61 |**13**|**DI_4**|Discrete input 4 (“dry contact”, +5V)
62 |**14**|**DI_3**|Discrete input 3 (“dry contact”, +5V)
63 |**15**|**DI_2**|Discrete input 2 (“dry contact”, +5V)
64 |**16**|**DI_1**|Discrete input 1 (“dry contact”, +5V)
Admin 27.1 65
66
67
Admin 82.2 68 === X2 – miniUSB connector ===
Admin 27.1 69
Admin 82.2 70 The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
Admin 55.3 71
Admin 82.2 72 === (% title="Click and drag to resize" %)​(%%)X3 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for power supply(%%) ===
73
Admin 81.5 74 Receptacle Housing: Molex 39012020. Terminals: Molex 5556
Admin 27.1 75
Admin 82.2 76 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
Admin 81.5 77
Admin 27.1 78 |**Pin**|**Name**|**Description**
Admin 81.5 79 |**1**|**GND**|Ground
Admin 82.2 80 |**2**|**V+**|Supply voltage (9-32V)
Admin 27.1 81
82
83
Admin 83.2 84 === X4, X5, X6, X7 – header of relay 1, 2, 3 and 4 ===
Admin 27.1 85
Admin 83.2 86 Receptacle Housing: Molex 39012020. Terminals: Molex 5556
Admin 55.3 87
Admin 86.2 88 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
Admin 27.1 89
90 |**Pin**|**Name**|**Description**
Admin 83.2 91 |**1**|**V+**|Switching voltage (up to 55V, max 3A)
92 |**2**|**NO**|Normally open contact
Admin 27.1 93
Admin 83.2 94 Contactor connection example for all relays:
Admin 27.1 95
Admin 86.2 96 [[image:1774456661980-866.png||data-xwiki-image-style-alignment="center" height="211" width="282"]]
Admin 27.1 97
Admin 51.1 98
Admin 86.2 99 === X8 – header for current sensor ===
Admin 27.1 100
Admin 55.3 101 Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
102
Admin 27.1 103 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
104
105 |**Pin**|**Name**|**Description**
Admin 38.1 106 |**1**|**CAN3_H**|CAN3 line H
107 |**2**|**CAN3_L**|CAN3 line L
Admin 27.1 108 |**3**|**GND**|Ground
109 |**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA)
110
111 (% class="box infomessage" %)
112 (((
Admin 38.1 113 **Note:**
114 CAN3 operates differently depending on used firmware:
Admin 27.1 115
Admin 38.1 116 * **BMS Main 3:** CAN3 bus is reserved;
Admin 39.1 117 * **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus:
Admin 38.1 118
119 [[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]]
120 )))
Admin 27.1 121
Admin 30.1 122 === X9 – header for BMS Logic (RS-485-2) ===
Admin 27.1 123
Admin 55.3 124 Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
125
Admin 27.1 126 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
127
128 |**Pin**|**Name**|**Description**
129 |**1**|**LOGIC_B**|RS-485 line B for communication with BMS Logic
130 |**2**|**LOGIC_A**|RS-485 line A for communication with BMS Logic
131 |**3**|**GND**|Ground
132 |**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA)
133
Admin 40.1 134 (% class="box infomessage" %)
135 (((
136 **Note:**
137 RS-485-2 operates differently depending on used firmware:
Admin 27.1 138
Admin 40.1 139 * **BMS Main 3X:** RS-485-2 bus is reserved;
140 * **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices:
Admin 27.1 141
Admin 40.1 142 [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]]
143 )))
144
Admin 82.2 145 === X10 – ===
Admin 27.1 146
Admin 30.1 147 === X11 – header for high-voltage bus before contactors (plus) ===
Admin 27.1 148
Admin 55.3 149 Receptacle Housing: Molex 436450200. Terminals: Molex 43030
150
Admin 27.1 151 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
152
153 |**Pin**|**Name**|**Description**
154 |**1**|**IN1+**|Plus of the high-voltage bus (before contactors)
155 |**2**|**IN1+**|Plus of the high-voltage bus (before contactors)
156
157 (% class="box warningmessage" %)
158 (((
159 The connected voltage must not exceed 1000V.
160 )))
161
Admin 30.1 162 === X12 – header for high-voltage bus before contactors (minus) ===
Admin 27.1 163
Admin 55.3 164 Receptacle Housing: Molex 436450200. Terminals: Molex 43030
165
Admin 27.1 166 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
167
168 |**Pin**|**Name**|**Description**
169 |**1**|**IN1-**|Minus of the high-voltage bus (before contactors)
170 |**2**|**IN1-**|Minus of the high-voltage bus (before contactors)
171
172 (% class="box warningmessage" %)
173 (((
174 The connected voltage must not exceed 1000V.
175 )))
176
Admin 30.1 177 === X13 – header for high-voltage bus after contactors (plus) ===
Admin 27.1 178
Admin 55.3 179 Receptacle Housing: Molex 436450200. Terminals: Molex 43030
180
Admin 27.1 181 [[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
182
183 |**Pin**|**Name**|**Description**
184 |**1**|**IN2+**|Plus of the high-voltage bus (after contactors)
185 |**2**|**IN2+**|Plus of the high-voltage bus (after contactors)
186
187 (% class="box warningmessage" %)
188 (((
189 The connected voltage must not exceed 1000V.
190 )))
191
Admin 30.1 192 === X14 – header for high-voltage bus after contactors (minus) ===
Admin 27.1 193
Admin 55.3 194 Receptacle Housing: Molex 436450200. Terminals: Molex 43030
195
Admin 27.1 196 [[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
197
198 |**Pin**|**Name**|**Description**
199 |**1**|**IN2-**|Minus of the high-voltage bus (after contactors)
200 |**2**|**IN2-**|Minus of the high-voltage bus (after contactors)
201
202 (% class="box warningmessage" %)
203 (((
204 The connected voltage must not exceed 1000V.
205 )))
206
Admin 30.1 207 === J1 – jumper for switching RS-485-1 bus terminal resistor ===
Admin 27.1 208
209 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
210
211 To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table:
212
213 |**Pin**|**Name**|**Description**
214 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected
215 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected
216
Admin 30.1 217 === J2 – jumper for switching CAN1 bus terminal resistor ===
Admin 27.1 218
219
220 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table:
221
222 |**Pin**|**Name**|**Description**
223 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected
224 |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected
225
Admin 30.1 226 === J3 – jumper for switching CAN2 bus terminal resistor ===
Admin 27.1 227
228
229 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H** and **CAN2_L** lines, install a jumper. The jumper is installed according to the table:
230
231 |**Pin**|**Name**|**Description**
232 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN2 bus is connected
233 |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN2 bus is disconnected
234
Admin 30.1 235 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
Admin 27.1 236
Admin 78.2 237 The BMS Main 2R device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
Admin 27.1 238
Admin 30.1 239 == Indicators ==
Admin 27.1 240
Admin 30.1 241 === DS1 – LED indicating device power ===
Admin 27.1 242
243 |**State**|**Description**
244 |**Lights up green**|Device power (+5V) is present
245 |**Doesn’t light up**|No device power
246
Admin 30.1 247 === DS2 – LED indicating device work ===
Admin 27.1 248
249 |**State**|**Description**
250 |**Blinking green**|Executing the battery management program
251 |**No blinking**|Program execution error
252
Admin 54.2 253 === DS3 – LED indicating interaction with child devices ===
Admin 27.1 254
Admin 54.2 255 (% style="width:447px" %)
256 |**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)**
257 |**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices
258 |**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)-
Admin 27.1 259
Admin 54.2 260 === DS4 – LED indicating loss of connection with child devices ===
Admin 27.1 261
Admin 54.4 262 (% style="width:601px" %)
263 |**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)**
264 |**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost
265 |**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable
Admin 27.1 266
Admin 30.1 267 === DS5-DS10 – LEDs indicating contactor switches 1-6 ===
Admin 27.1 268
269 |**State**|**Description**
270 |**Lights up green**|The switch supplies voltage to the contactor winding
271 |**Doesn’t light up**|The switch doesn’t supply voltage to the contactor winding
272
Admin 30.1 273 === DS11 – LED indicating the presence of power supply for contactors ===
Admin 27.1 274
275 |**State**|**Description**
276 |**Lights up green**|Power supply for contactor switches (9-32V) is present
277 |**Doesn’t light up**|Power supply for contactor switches (9-32V) is not present
278
Admin 30.1 279 == Connection procedure ==
Admin 27.1 280
281 All operations to connect the device must be carried out with the supply voltage removed.
282
283 * Connect the power contactors to header X2.
284 * Connect one or more current sensors, as well as external temperature sensors (if necessary) to header X5.
285 * Connect BMS Logic devices to header X9.
286 * Connect digital inputs and outputs (if necessary) to header X3.
287 * Connect the high voltage bus (if necessary) to headers X11-X14.
288 * Connect the high-voltage network integrity circuit (if necessary) to header X4.
289 * Connect external devices (if necessary) to header X6.