Last modified by Admin on 2026/04/02 13:49

From version 90.2
edited by Admin
on 2026/04/02 13:49
Change comment: Update document after refactoring.
To version 87.3
edited by Admin
on 2026/03/25 16:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Main 2R.WebHome
1 +drafts.BMS Main 2R.WebHome
Content
... ... @@ -128,110 +128,152 @@
128 128  
129 129  |**Pin**|**Name**|**Description**
130 130  |**1, 2**|**GND**|Ground
131 -|**3**|**T_SENS1**|Temperature sensor 1 output
132 -|**4**|**T_SENS2**|Temperature sensor 2 output
131 +|**3**|**T_SENS1**|Ground
132 +|**4**|**T_SENS2**|Current sensor 2 output
133 133  
134 -=== X11 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for BMS Logic(%%) ===
134 +=== X11 – header for high-voltage bus before contactors (plus) ===
135 135  
136 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
136 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
137 137  
138 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
138 +[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
139 139  
140 140  |**Pin**|**Name**|**Description**
141 -|**1**|**LOGIC_A**|RS-485 line A for communication with BMS Logic
142 -|**2**|**LOGIC_B**|RS-485 line B for communication with BMS Logic
143 -|**3**|**LOGIC_5V**|Supply voltage for BMS Logic
144 -|**4**|**GND**|Ground
141 +|**1**|**IN1+**|Plus of the high-voltage bus (before contactors)
142 +|**2**|**IN1+**|Plus of the high-voltage bus (before contactors)
145 145  
146 -=== X12 – header for CAN2 interface ===
144 +(% class="box warningmessage" %)
145 +(((
146 +The connected voltage must not exceed 1000V.
147 +)))
147 147  
148 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
149 +=== X12 – header for high-voltage bus before contactors (minus) ===
149 149  
150 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
151 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
151 151  
153 +[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
154 +
152 152  |**Pin**|**Name**|**Description**
153 -|**1**|**CAN2_H**|CAN2 H line for communication with internal equipment
154 -|**2**|**CAN2_L**|CAN2 L line for communication with internal equipment
155 -|**3**|**–**|–
156 -|**4**|**GND**|Ground
156 +|**1**|**IN1-**|Minus of the high-voltage bus (before contactors)
157 +|**2**|**IN1-**|Minus of the high-voltage bus (before contactors)
157 157  
158 -=== X13 – header for CAN1 and RS-485 interfaces ===
159 +(% class="box warningmessage" %)
160 +(((
161 +The connected voltage must not exceed 1000V.
162 +)))
159 159  
160 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030
164 +=== X13 – header for high-voltage bus after contactors (plus) ===
161 161  
162 -[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]]
166 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
163 163  
168 +[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
169 +
164 164  |**Pin**|**Name**|**Description**
165 -|**1**|**RS485_1_A**|RS-485-1 line A for communication with external equipment
166 -|**2**|**CAN1_H**|CAN1 H line for communication with external equipment
167 -|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA
168 -|**4**|**RS485_1_B**|RS-485-1 line B for communication with external equipment
169 -|**5**|**CAN1_L**|CAN1 L line for communication with external equipment
170 -|**6**|**GND**|Ground
171 +|**1**|**IN2+**|Plus of the high-voltage bus (after contactors)
172 +|**2**|**IN2+**|Plus of the high-voltage bus (after contactors)
171 171  
172 -=== J1 – jumper for switching CAN2 bus terminal resistor ===
174 +(% class="box warningmessage" %)
175 +(((
176 +The connected voltage must not exceed 1000V.
177 +)))
173 173  
179 +=== X14 – header for high-voltage bus after contactors (minus) ===
174 174  
175 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H **and **CAN2_L **lines, install a jumper. The jumper is installed according to the table:
181 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
176 176  
183 +[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
184 +
177 177  |**Pin**|**Name**|**Description**
178 -|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected
179 -|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected
186 +|**1**|**IN2-**|Minus of the high-voltage bus (after contactors)
187 +|**2**|**IN2-**|Minus of the high-voltage bus (after contactors)
180 180  
181 -=== J2 – jumper for switching RS-485-1 bus terminal resistor ===
189 +(% class="box warningmessage" %)
190 +(((
191 +The connected voltage must not exceed 1000V.
192 +)))
182 182  
194 +=== J1 – jumper for switching RS-485-1 bus terminal resistor ===
195 +
183 183  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
184 184  
185 -To connect a terminal resistor between the **RS485_1_A **and **RS485_1_B **lines, install a jumper. The jumper is installed according to the table:
198 +To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table:
186 186  
187 187  |**Pin**|**Name**|**Description**
188 188  |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected
189 189  |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected
190 190  
191 -=== J3 – jumper for switching CAN1 bus terminal resistor ===
204 +=== J2 – jumper for switching CAN1 bus terminal resistor ===
192 192  
193 193  
194 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H **and **CAN1_L **lines, install a jumper. The jumper is installed according to the table:
207 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table:
195 195  
196 196  |**Pin**|**Name**|**Description**
197 197  |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected
198 198  |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected
199 199  
213 +=== J3 – jumper for switching CAN2 bus terminal resistor ===
214 +
215 +
216 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H** and **CAN2_L** lines, install a jumper. The jumper is installed according to the table:
217 +
218 +|**Pin**|**Name**|**Description**
219 +|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN2 bus is connected
220 +|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN2 bus is disconnected
221 +
222 +=== J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
223 +
224 +The BMS Main 2R device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
225 +
200 200  == Indicators ==
201 201  
202 -=== DS2operation indicator ===
228 +=== DS1LED indicating device power ===
203 203  
204 204  |**State**|**Description**
205 -|**Blinking green**|The BMS firmware is running
206 -|**Off**|The BMS firmware is not running
231 +|**Lights up green**|Device power (+5V) is present
232 +|**Doesn’t light up**|No device power
207 207  
208 -=== DS3communication indicator ===
234 +=== DS2LED indicating device work ===
209 209  
210 210  |**State**|**Description**
211 -|**Blinking yellow (2Hz)**|Initializing communication with BMS Logic boards
212 -|**Blinking yellow (25Hz)**|Communication with BMS Logic is established
237 +|**Blinking green**|Executing the battery management program
238 +|**No blinking**|Program execution error
213 213  
214 -=== DS4error indicator ===
240 +=== DS3LED indicating interaction with child devices ===
215 215  
242 +(% style="width:447px" %)
243 +|**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)**
244 +|**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices
245 +|**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)-
246 +
247 +=== DS4 – LED indicating loss of connection with child devices ===
248 +
249 +(% style="width:601px" %)
250 +|**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)**
251 +|**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost
252 +|**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable
253 +
254 +=== DS5-DS10 – LEDs indicating contactor switches 1-6 ===
255 +
216 216  |**State**|**Description**
217 -|**Blinking red**|Errors in communication with BMS Logic
257 +|**Lights up green**|The switch supplies voltage to the contactor winding
258 +|**Doesn’t light up**|The switch doesn’t supply voltage to the contactor winding
218 218  
219 -=== DS1.1-DS1.4 – relay 1-4 indicator ===
260 +=== DS11 – LED indicating the presence of power supply for contactors ===
220 220  
221 221  |**State**|**Description**
222 -|**Lights green**|Relay #1-#4 is closed
223 -|**Off**|Relay #1-#4 is opened
263 +|**Lights up green**|Power supply for contactor switches (9-32V) is present
264 +|**Doesn’t light up**|Power supply for contactor switches (9-32V) is not present
224 224  
225 225  == Connection procedure ==
226 226  
227 227  All operations to connect the device must be carried out with the supply voltage removed.
228 228  
229 -* Connect the power contactors to headers X4-X7.
230 -* Connect one or more current sensors to headers X8 and X9.
231 -* Connect external temperature sensors (if necessary) to header X10.
232 -* Connect BMS Logic devices to header X11.
233 -* Connect digital inputs and outputs (if necessary) to header X1.
234 -* Connect external devices (if necessary) to header X13.
235 -* Connect other devices (BMS Indication, BMS Display, if necessary) to header X12.
236 -* If the BMS Main 2R is the last device on the CAN2,  RS-485-1 or CAN1 bus, install jumpers J1-J3.
237 -* Connect an external power supply to header X3. The device will start when there is a 9-32V power supply.
270 +* Connect the power contactors to header X2.
271 +* Connect one or more current sensors, as well as external temperature sensors (if necessary) to header X5.
272 +* Connect BMS Logic devices to header X9.
273 +* Connect digital inputs and outputs (if necessary) to header X3.
274 +* Connect the high voltage bus (if necessary) to headers X11-X14.
275 +* Connect the high-voltage network integrity circuit (if necessary) to header X4.
276 +* Connect external devices (if necessary) to header X6.
277 +* Connect other devices (BMS Indication, BMS Display, if necessary) to header X7.
278 +* If the BMS Main 2R is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.
279 +* Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.