Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -138,24 +138,24 @@ 138 138 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 139 139 140 140 |**Pin**|**Name**|**Description** 141 -|**1**|**LOGIC_A**|RS-485 line A for communication with BMS Logic 142 -|**2**|**LOGIC_B**|RS-485 line B for communication with BMS Logic 143 -|**3**|** LOGIC_5V**|Supply voltage for BMS Logic141 +|**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic 142 +|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic 143 +|**3**|**+5V**|Supply voltage for BMS Logic 144 144 |**4**|**GND**|Ground 145 145 146 -=== X12 – header for CAN 2interface ===146 +=== X12 – header for internal CAN interface === 147 147 148 148 Receptacle Housing: Molex 430250400. Terminals: Molex 43030 149 149 150 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] By defaul150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 151 151 152 152 |**Pin**|**Name**|**Description** 153 -|**1**|**CAN 2_H**|RS-485 line A for communication with BMS Logic154 -|**2**|**CAN 2_L**|CAN L line for communication with external equipment153 +|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic 154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment 155 155 |**3**|**–**|– 156 156 |**4**|**GND**|Ground 157 157 158 -=== X13 – header for CAN 1and RS-485 interfaces ===158 +=== X13 – header for external CAN and RS-485 interfaces === 159 159 160 160 Receptacle Housing: Molex 430250600. Terminals: Molex 43030 161 161 ... ... @@ -162,36 +162,27 @@ 162 162 [[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]] 163 163 164 164 |**Pin**|**Name**|**Description** 165 -|**1**|**RS 485_1_A**|RS-485 line A for communication with external equipment166 -|**2**|**CAN 1_H**|CAN H line for communication with external equipment165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment 166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment 167 167 |**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 -|**4**|**RS 485_1_B**|RS-485 line B for communication with external equipment169 -|**5**|**CAN 1_L**|CAN L line for communication with external equipment168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment 169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment 170 170 |**6**|**GND**|Ground 171 171 172 -=== J1 – jumper for switching internalCANbus terminal resistor ===172 +=== J1 – jumper for switching RS-485 bus terminal resistor === 173 173 174 - 175 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H **and **CAN2_L **lines, install a jumper. The jumper is installed according to the table: 176 - 177 -|**Pin**|**Name**|**Description** 178 -|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected 179 -|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected 180 - 181 -=== J2 – jumper for switching RS-485 bus terminal resistor === 182 - 183 183 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 184 184 185 -To connect a terminal resistor between the **RS485_1_A **and**RS485_1_B**lines, install a jumper. The jumper is installed according to the table:176 +To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: 186 186 187 187 |**Pin**|**Name**|**Description** 188 188 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected 189 189 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected 190 190 191 -=== J 3– jumper for switchingexternalCAN bus terminal resistor ===182 +=== J2 – jumper for switching CAN1 bus terminal resistor === 192 192 193 193 194 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H **and **CAN1_L**lines, install a jumper. The jumper is installed according to the table:185 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table: 195 195 196 196 |**Pin**|**Name**|**Description** 197 197 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected