Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -128,70 +128,83 @@ 128 128 129 129 |**Pin**|**Name**|**Description** 130 130 |**1, 2**|**GND**|Ground 131 -|**3**|**T_SENS1**| Temperature sensor 1 output132 -|**4**|**T_SENS2**| Temperature sensor 2output131 +|**3**|**T_SENS1**|Ground 132 +|**4**|**T_SENS2**|Current sensor 2 output 133 133 134 -=== X11 – (% style="color:inherit; font-family:inherit;font-size:max(18px,min(20px, 14.4444px + 0.462963vw))" %)headerforBMS Logic(%%) ===134 +=== X11 – header for high-voltage bus before contactors (plus) === 135 135 136 -Receptacle Housing: Molex 4302 50400. Terminals: Molex 43030136 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 137 137 138 -[[image:173 2198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]138 +[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 139 139 140 140 |**Pin**|**Name**|**Description** 141 -|**1**|**LOGIC_A**|RS-485 line A for communication with BMS Logic 142 -|**2**|**LOGIC_B**|RS-485 line B for communication with BMS Logic 143 -|**3**|**LOGIC_5V**|Supply voltage for BMS Logic 144 -|**4**|**GND**|Ground 141 +|**1**|**IN1+**|Plus of the high-voltage bus (before contactors) 142 +|**2**|**IN1+**|Plus of the high-voltage bus (before contactors) 145 145 146 -=== X12 – header for CAN2 interface === 144 +(% class="box warningmessage" %) 145 +((( 146 +The connected voltage must not exceed 1000V. 147 +))) 147 147 148 - ReceptacleHousing: Molex430250400.Terminals: Molex43030149 +=== X12 – header for high-voltage bus before contactors (minus) === 149 149 150 - [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center"height="77"width="71"]]Bydefaul151 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 151 151 153 +[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 154 + 152 152 |**Pin**|**Name**|**Description** 153 -|**1**|**CAN2_H**|RS-485 line A for communication with BMS Logic 154 -|**2**|**CAN2_L**|CAN L line for communication with external equipment 155 -|**3**|**–**|– 156 -|**4**|**GND**|Ground 156 +|**1**|**IN1-**|Minus of the high-voltage bus (before contactors) 157 +|**2**|**IN1-**|Minus of the high-voltage bus (before contactors) 157 157 158 -=== X13 – header for CAN1 and RS-485 interfaces === 159 +(% class="box warningmessage" %) 160 +((( 161 +The connected voltage must not exceed 1000V. 162 +))) 159 159 160 - ReceptacleHousing: Molex430250600.Terminals: Molex43030164 +=== X13 – header for high-voltage bus after contactors (plus) === 161 161 162 - [[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center"height="81" width="113"]]166 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 163 163 168 +[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 169 + 164 164 |**Pin**|**Name**|**Description** 165 -|**1**|**RS485_1_A**|RS-485 line A for communication with external equipment 166 -|**2**|**CAN1_H**|CAN H line for communication with external equipment 167 -|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 -|**4**|**RS485_1_B**|RS-485 line B for communication with external equipment 169 -|**5**|**CAN1_L**|CAN L line for communication with external equipment 170 -|**6**|**GND**|Ground 171 +|**1**|**IN2+**|Plus of the high-voltage bus (after contactors) 172 +|**2**|**IN2+**|Plus of the high-voltage bus (after contactors) 171 171 172 -=== J1 – jumper for switching internal CAN bus terminal resistor === 174 +(% class="box warningmessage" %) 175 +((( 176 +The connected voltage must not exceed 1000V. 177 +))) 173 173 179 +=== X14 – header for high-voltage bus after contactors (minus) === 174 174 175 - [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center"height="77" width="148"]]Toconnect a terminal resistor betweenthe **CAN2_H **and **CAN2_L **lines,install a jumper. Thejumperis installed according to the table:181 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 176 176 183 +[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 184 + 177 177 |**Pin**|**Name**|**Description** 178 -|**1 -2**|**120 Ohm**|The 120 Ohm terminal resistorof theCAN1busisconnected179 -|**2 -3**|**-**|The 120 Ohm terminal resistorof theCAN1busisdisconnected186 +|**1**|**IN2-**|Minus of the high-voltage bus (after contactors) 187 +|**2**|**IN2-**|Minus of the high-voltage bus (after contactors) 180 180 181 -=== J2 – jumper for switching RS-485 bus terminal resistor === 189 +(% class="box warningmessage" %) 190 +((( 191 +The connected voltage must not exceed 1000V. 192 +))) 182 182 194 +=== J1 – jumper for switching RS-485-1 bus terminal resistor === 195 + 183 183 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 184 184 185 -To connect a terminal resistor between the **RS485_1_A **and**RS485_1_B**lines, install a jumper. The jumper is installed according to the table:198 +To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: 186 186 187 187 |**Pin**|**Name**|**Description** 188 188 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected 189 189 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected 190 190 191 -=== J 3– jumper for switchingexternalCAN bus terminal resistor ===204 +=== J2 – jumper for switching CAN1 bus terminal resistor === 192 192 193 193 194 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H **and **CAN1_L**lines, install a jumper. The jumper is installed according to the table:207 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table: 195 195 196 196 |**Pin**|**Name**|**Description** 197 197 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected