Last modified by Admin on 2026/04/02 13:49

From version 89.7
edited by Admin
on 2026/03/25 16:55
Change comment: There is no comment for this version
To version 89.6
edited by Admin
on 2026/03/25 16:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -139,11 +139,11 @@
139 139  
140 140  |**Pin**|**Name**|**Description**
141 141  |**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic
142 -|**2**|**LOGIC_B**|RS-485 line B for communication with BMS Logic
142 +|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic
143 143  |**3**|**+5V**|Supply voltage for BMS Logic
144 144  |**4**|**GND**|Ground
145 145  
146 -=== X12 – header for CAN2 interface ===
146 +=== X12 – header for internal CAN2 interface ===
147 147  
148 148  Receptacle Housing: Molex 430250400. Terminals: Molex 43030
149 149  
... ... @@ -150,8 +150,8 @@
150 150  [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
151 151  
152 152  |**Pin**|**Name**|**Description**
153 -|**1**|**CAN2_H**|RS-485 line A for communication with BMS Logic
154 -|**2**|**CAN2_L**|CAN L line for communication with external equipment
153 +|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic
154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment
155 155  |**3**|**–**|–
156 156  |**4**|**GND**|Ground
157 157  
... ... @@ -162,11 +162,11 @@
162 162  [[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]]
163 163  
164 164  |**Pin**|**Name**|**Description**
165 -|**1**|**RS485_1_A**|RS-485 line A for communication with external equipment
166 -|**2**|**CAN1_H**|CAN H line for communication with external equipment
165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment
166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment
167 167  |**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA
168 -|**4**|**RS485_1_B**|RS-485 line B for communication with external equipment
169 -|**5**|**CAN1_L**|CAN L line for communication with external equipment
168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment
169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment
170 170  |**6**|**GND**|Ground
171 171  