Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -143,7 +143,7 @@ 143 143 |**3**|**+5V**|Supply voltage for BMS Logic 144 144 |**4**|**GND**|Ground 145 145 146 -=== X12 – header for internal CAN 2interface ===146 +=== X12 – header for internal CAN interface === 147 147 148 148 Receptacle Housing: Molex 430250400. Terminals: Molex 43030 149 149 ... ... @@ -151,35 +151,41 @@ 151 151 152 152 |**Pin**|**Name**|**Description** 153 153 |**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic 154 -|**2**|**CAN_INT_L**| CANLline for communication withexternalequipment155 -|**3**|** –**|–154 +|**2**|**CAN_INT_L**|RS-485 line B for communication with BMS Logic 155 +|**3**|**+5V**|Supply voltage for BMS Logic 156 156 |**4**|**GND**|Ground 157 157 158 -=== X13 – header for CAN 1and RS-485 interfaces ===158 +=== X13 – header for external CAN and RS-485 interfaces === 159 159 160 160 Receptacle Housing: Molex 430250600. Terminals: Molex 43030 161 161 162 -[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center"height="81" width="113"]]162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" height="81" width="113"]] 163 163 164 164 |**Pin**|**Name**|**Description** 165 -|**1**|** RS_EXT_A**|RS-485 line A for communication with external equipment166 -|**2**|**CAN_ EXT_H**|CAN H line for communication with external equipment167 -|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 -|**4**|** RS_EXT_B**|RS-485 line B for communication with external equipment169 -|**5**|**CAN_ EXT_L**|CAN L line for communication with external equipment170 -|**6**|**GND**|Ground 165 +|**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment 166 +|**2**|**CAN_H**|CAN H line for communication with external equipment 167 +|**3**|**+5V_CAN**|Supply voltage 5V for external devices, max 200 mA 168 +|**4**|**EXT_RS485_B**|RS-485 line B for communication with external equipment 169 +|**5**|**CAN_L**|CAN L line for communication with external equipment 170 +|**6**|**GND_CAN**|Ground 171 171 172 -=== J1 –jumper forswitchingCAN2bus terminalresistor===172 +=== X14 – header for high-voltage bus after contactors (minus) === 173 173 174 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 174 174 175 -[[image:1733316 982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN_INT_H **and **CAN_L** lines, install a jumper. The jumper is installed according to the table:176 +[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 176 176 177 177 |**Pin**|**Name**|**Description** 178 -|**1 -2**|**120 Ohm**|The 120 Ohm terminal resistorof theCAN1busisconnected179 -|**2 -3**|**-**|The 120 Ohm terminal resistorof theCAN1busisdisconnected179 +|**1**|**IN2-**|Minus of the high-voltage bus (after contactors) 180 +|**2**|**IN2-**|Minus of the high-voltage bus (after contactors) 180 180 181 -=== J2 – jumper for switching RS-485 bus terminal resistor === 182 +(% class="box warningmessage" %) 183 +((( 184 +The connected voltage must not exceed 1000V. 185 +))) 182 182 187 +=== J1 – jumper for switching RS-485-1 bus terminal resistor === 188 + 183 183 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 184 184 185 185 To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: ... ... @@ -188,10 +188,10 @@ 188 188 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected 189 189 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected 190 190 191 -=== J 3– jumper for switching CAN1 bus terminal resistor ===197 +=== J2 – jumper for switching CAN1 bus terminal resistor === 192 192 193 193 194 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN_ EXT_H** and **CAN_EXT_L**lines, install a jumper. The jumper is installed according to the table:200 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table: 195 195 196 196 |**Pin**|**Name**|**Description** 197 197 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected