... ... @@ -143,7 +143,7 @@
143 143  |**3**|**+5V**|Supply voltage for BMS Logic
144 144  |**4**|**GND**|Ground
145 145  
146 -=== X12 – header for internal CAN2 interface ===
146 +=== X12 – header for internal CAN interface ===
147 147  
148 148  Receptacle Housing: Molex 430250400. Terminals: Molex 43030
149 149  
... ... @@ -155,7 +155,7 @@
155 155  |**3**|**–**|–
156 156  |**4**|**GND**|Ground
157 157  
158 -=== X13 – header for CAN1 and RS-485 interfaces ===
158 +=== X13 – header for external CAN and RS-485 interfaces ===
159 159  
160 160  Receptacle Housing: Molex 430250600. Terminals: Molex 43030
161 161  
... ... @@ -169,8 +169,23 @@
169 169  |**5**|**CAN_EXT_L**|CAN L line for communication with external equipment
170 170  |**6**|**GND**|Ground
171 171  
172 -=== J1 – jumper for switching RS-485 bus terminal resistor ===
172 +=== X14header for high-voltage bus after contactors (minus) ===
173 173  
174 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
175 +
176 +[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
177 +
178 +|**Pin**|**Name**|**Description**
179 +|**1**|**IN2-**|Minus of the high-voltage bus (after contactors)
180 +|**2**|**IN2-**|Minus of the high-voltage bus (after contactors)
181 +
182 +(% class="box warningmessage" %)
183 +(((
184 +The connected voltage must not exceed 1000V.
185 +)))
186 +
187 +=== J1 – jumper for switching RS-485-1 bus terminal resistor ===
188 +
174 174  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
175 175  