Last modified by Admin on 2026/04/02 13:49

From version 89.2
edited by Admin
on 2026/03/25 16:45
Change comment: There is no comment for this version
To version 89.4
edited by Admin
on 2026/03/25 16:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -143,7 +143,7 @@
143 143  |**3**|**+5V**|Supply voltage for BMS Logic
144 144  |**4**|**GND**|Ground
145 145  
146 -=== X12 – header for internal CAN interface ===
146 +=== X12 – header for internal CAN2 interface ===
147 147  
148 148  Receptacle Housing: Molex 430250400. Terminals: Molex 43030
149 149  
... ... @@ -155,7 +155,7 @@
155 155  |**3**|**–**|–
156 156  |**4**|**GND**|Ground
157 157  
158 -=== X13 – header for external CAN and RS-485 interfaces ===
158 +=== X13 – header for CAN1 and RS-485 interfaces ===
159 159  
160 160  Receptacle Housing: Molex 430250600. Terminals: Molex 43030
161 161  
... ... @@ -169,23 +169,8 @@
169 169  |**5**|**CAN_EXT_L**|CAN L line for communication with external equipment
170 170  |**6**|**GND**|Ground
171 171  
172 -=== X14header for high-voltage bus after contactors (minus) ===
172 +=== J1 – jumper for switching RS-485 bus terminal resistor ===
173 173  
174 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
175 -
176 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
177 -
178 -|**Pin**|**Name**|**Description**
179 -|**1**|**IN2-**|Minus of the high-voltage bus (after contactors)
180 -|**2**|**IN2-**|Minus of the high-voltage bus (after contactors)
181 -
182 -(% class="box warningmessage" %)
183 -(((
184 -The connected voltage must not exceed 1000V.
185 -)))
186 -
187 -=== J1 – jumper for switching RS-485-1 bus terminal resistor ===
188 -
189 189  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
190 190  
191 191  To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: